DCL-05-111, Withdrawal Request for Approval of Extreme Growth Method

From kanterella
Jump to navigation Jump to search
Withdrawal Request for Approval of Extreme Growth Method
ML052760158
Person / Time
Site: Diablo Canyon  Pacific Gas & Electric icon.png
Issue date: 09/22/2005
From: Oatley D
Pacific Gas & Electric Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
DCL-05-111
Download: ML052760158 (2)


Text

Pacific Gas and Electric Company David H. Oatley Diablo Canyon Power Plant Vice President and PO. Box 56 General Manager Avila Beach, CA 93424 September 22, 2005 805.545.4350 Fax: 805.545.4234 PG&E Letter DCL-05-1 11 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Docket No. 50-275, OL-DPR-80 Docket No. 50-323, OL-DPR-82 Diablo Canyon Units 1 and 2 Withdrawal of Request for Approval of Extreme Growth Method

Dear Commissioners and Staff:

Pacific Gas and Electric Company (PG&E) Letter DCL-04-028, dated March 18, 2004, submitted License Amendment Request (LAR) 04-01, "Revised Steam Generator Voltage-based Repair Criteria Probability of Detection Method for DCPP Units 1 and 2." LAR 04-01 requested approval to use the probability of prior cycle detection (POPCD) method on a permanent basis for all remaining cycles for Diablo Canyon Power Plant (DCPP) Units 1 and 2 until steam generator replacement. In DCL-04-028, PG&E stated that upon NRC approval to use the POPCD method, PG&E would adopt the Electric Power Research Institute (EPRI) outlier (extreme) growth method for application coincident with the use of the POPCD method.

Subsequently, in PG&E Letter DCL-04-117, dated September 17, 2004, "Response to August 24, 2004, NRC Request for Additional Information Regarding License Amendment Request 04-01, 'Revised Steam Generator Voltage-based Repair Criteria Probability of Detection Method for DCPP Units 1 and 2,"' PG&E stated that it did not need approval of the EPRI extreme growth method for Unit 2 Cycle 13 based on the NRC's acceptance of PG&E's exclusion criteria for the extreme growth rate observed in Unit 2 Refueling Outage No. 11, and the extreme growth method could be approved at a later time.

On October 28, 2004, the NRC issued License Amendments 177 (Unit 1) and 179 (Unit 2), approving LAR 04-01, without completing its review.of the extreme growth method as submitted in LAR 04-01.

PG&E has determined that extreme growth at DCPP has a very low probability of occurrence, largely due to increased Plus Point inspections and conservative preventive plugging criteria. Therefore, PG&E withdraws its request for NRC approval of the extreme growth method as submitted in LAR 04-01.

A member of the STARS (Strategic Teaming and Resource Sharing)

Alliance Callaway

  • Comanche Peak
  • Diablo Canyon
  • Palo Verde
  • Wolf Creek

Document Control Desk September 22, 2005 Page 2 PG&E Letter DCL-05-1 11 If you have any questions, or require additional information, please contact Stan Ketelsen at (805) 545-4720.

Sin atn David H. Oatley Vice President and General Manager jerl/3664 cc:

Edgar Bailey, DHS Terry W. Jackson Bruce S. Mallett Girija'S. Shukla Diablo Distribution A member of the STARS (Strategic Teaming and Resource Sharing)

Alliance Callaway

  • Comanche Peak
  • Diablo Canyon
  • Palo Verde
  • Wolf Creek