CY-04-231, Registration of Spent Fuel Dry Cask in Use at the Haddam Neck Plant (HNP) Independent Spent Fuel Storage Installation (ISFSI)

From kanterella
(Redirected from CY-04-231)
Jump to navigation Jump to search
Registration of Spent Fuel Dry Cask in Use at the Haddam Neck Plant (HNP) Independent Spent Fuel Storage Installation (ISFSI)
ML043360265
Person / Time
Site: Haddam Neck  File:Connecticut Yankee Atomic Power Co icon.png
Issue date: 11/22/2004
From: Gerard van Noordennen
Connecticut Yankee Atomic Power Co
To:
Document Control Desk, NRC/NMSS/SFPO
References
+KBR1SISP20050509, CY-04-231, FOIA/PA-2005-0203
Download: ML043360265 (2)


Text

-;

CONNECTICUT YANKEE ATOMIC POWER COMPANY HADDAM NECK PLANT 362 INJUN HOLLOW ROAD

  • EAST HAMPTON, CT 06424-3099 NOV 22 2004 CY-04-231 License No. DPR-61 Docket No. 50-213 Docket No. 72-0039 Re: 10 CFR 72.212 Director, Spent Fuel Project Office Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555 Haddam Neck Plant Registration of Spent Fuel Dry Cask in use at the Haddam Neck Plant (HNP) Independent Spent Fuel Storage Installation (ISFSI) ln:accordance with, 1 0 CFR 72.21 2(b)(1 )(ii),, Connecticut Yankee Atomic Power Company (CYAPCO) is registering the use of a spent fuel dry cask to store spent fuel under a 10 CFR Part 72 general license at the HNPP ISFSI.

Licensee's Name: Connecticut Yankee Atomic Power Company Licensee's Address: Haddam Neck Plant 362 Injun Hollow Road East Hampton, CT 06424-3099 Reactor License Number: DPR-61 Reactor Docket No.: 50-213 ISFSI Docket No.: 72-0039 Contact Name and

Title:

G. P. van Noordennen, Regulatory Affairs Manager Cask Certification No.: Certificate.of Compliance 1025, Amendment Nd 3, October 1, 2003

-ss

Document Control Center CY-04-231 / Page 2 Cask Model No.: NAC-MPC Cask Identification Nos.: Transportable storage canister (TSC) Identification No.

CY-MPC-TSC-414-29 Vertical Concrete Cask (VCC) Identification No.: CY-VCC-29 Date in Service: November 9, 2004 There are no regulatory commitments contained in this letter.

If you should have any questions regarding this submittal, please contact me at (860) 267-3938.

Sincerely, Gerard P. van Noordennen Regulatory Affairs Manager Da/-t-e/

Date cc=

S. J. Collins, NRC Region 1 Administrator T. B. Smith, NRC Project Manager, Haddam Neck Plant R. R. Bellamy, Chief, Decommissioning and Laboratory Branch, NRC Region 1 E. L. Wilds, Jr., Director, CT DEP, Monitoring and Radiation Division