Entergy Operations, Inc.

1340 Echelon Parkway ntergy Jackson, Mississippi 39213-8298 Tel 601-368-5758 F. G. Burford Acting Director Nuclear Safety &Licensing CNRO-2006-00037 July 31, 2006 U. S. Nuclear Regulatory Commission Attn.: Document Control Desk Washington, DC 20555-0001

SUBJECT:

Withdrawal of Request for Alternative W3-R&R-005 Waterford Steam Electric Station, Unit 3 Docket No. 50-382 License No. NPF-38

REFERENCE:

Entergy Operations, Inc. letter CNRO-2006-00009 to the NRC dated February 24, 2006

Dear Sir or Madam:

In the referenced letter, Entergy Operations, Inc. (Entergy) submitted Relief for Alternative W3-R&R-005 for the Waterford Steam Electric Station, Unit 3 (Waterford 3). This request proposed to use K1, vs. KIa and elastic-plastic fracture mechanics (EPFM) with associated acceptance criteria. This request had been submitted in support of analyses to qualify the Waterford 3 pressurizer with respect to recently-identified insurge/outsurge transient loading conditions.

While there has been industry precedence for such a request, Entergy has reviewed the ASME Code requirements and has concluded that NRC approval of the request is not required. This conclusion is based on the following points:

1. The rules of IWB-3000 are only applicable to flaws discovered by the examinations required by IWB-2500, and
2. Deviations to non-mandatory ASME Code appendices do not require NRC approval.

Therefore, by this letter, Entergy withdraws W3-R&R-005.

Representatives from the NRC staff and Entergy have discussed this request and the logic for withdrawal in several telephone calls. As discussed in these calls, Entergy will provide the results of the flaw evaluation to the staff following the guidance of ASME Section Xl IWB-3134. Entergy expects to submit the evaluation on or before August 31, 2006. This commitment is reflected in the attachment to this letter. In addition, Entergy withdraws the commitments made in the referenced letter.

CNRO-2006-00037 Page 2 of 2 Should you have any questions regarding this letter, please contact Guy Davant at (601) 368-5756.

Very truly yours, FGB/GHD/ghd

Attachment:

Licensee-Identified Commitments cc: Mr. W. A. Eaton (ECH)

Mr. J. E. Venable (W3)

Dr. Bruce. S. Mallett Regional Administrator, Region IV U. S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 400 Arlington, TX 76011-8064 NRC Senior Resident Inspector Waterford Steam Electric Station, Unit 3 P. 0. Box 822 Killona, LA 70066 U. S. Nuclear Regulatory Commission Attn: Mr. M. B. Fields MS 0-7 D1 Washington, DC 20555-0001

Attachment to CNRO-2006-00037 Page 1 of 1 LICENSEE-IDENTIFIED COMMITMENTS TYPE (Check one) SCHEDULED ONE-TIME CONTINUING COMPLETION COMMITMENT ACTION COMPLIANCE DATE Entergy will provide the results of the flaw evaluation V, 8/31/06 to the staff.

Entergy withdraws the commitments made in Entergy letter CNRO-2006-00009 dated February 24, 2006.