CAC:MF6388
From kanterella
Jump to navigation
Jump to search
Request for: Approved, Closed | |
Initiation
Questions Answers | |
From | |
MONTHYEARL-2015-099, Fifth Ten-Year Interval Inservice Testing (IST) Program, Relief Request No. PR-022015-06-10010 June 2015
[table view]Title: Fifth Ten-Year Interval Inservice Testing (IST) Program, Relief Request No. PR-02 Site: Turkey Point L-2015-224, Fifth Ten-Year Interval Inservice Testing (IST) Program, Relief Request No. PR-022015-09-25025 September 2015 Title: Fifth Ten-Year Interval Inservice Testing (IST) Program, Relief Request No. PR-02 Site: Turkey Point ML15363A1412015-11-10010 November 2015 Title: NRC Staffs LIC-109 Acceptance Review Results for Turkey Point 3 4 Relief Request No. PR-02 for the 5th 10-Year IST Interval Site: Turkey Point ML16011A2052016-01-22022 January 2016 Title: Safety Evaluation for Relief Request No. PR-02, for the Fifth 10-Year Inservice Testing Interval Regarding Requirements for the Quarterly Testing of the Residual Heat Removal Pumps (CAC Nos. MF6388 & MF6389) Site: Turkey Point 2015-06-10 |
Retrieved from "https://kanterella.com/w/index.php?title=CAC:MF6388&oldid=483704"