A820020, Forwards Revision to Inservice Testing Relief Requests Re Pump Vibration Testing

From kanterella
Jump to navigation Jump to search
Forwards Revision to Inservice Testing Relief Requests Re Pump Vibration Testing
ML20066A834
Person / Time
Site: Cooper Entergy icon.png
Issue date: 10/28/1982
From: Pilant J
NEBRASKA PUBLIC POWER DISTRICT
To: Vassallo D
Office of Nuclear Reactor Regulation
References
LQA8200205, NUDOCS 8211060238
Download: ML20066A834 (2)


Text

[-}

GENERAL OFFICE hN Nebraska Public Power District etcA'se"S$'""^M^ **' "'"

LQA8200205 October 28, 1982 Office of Nuclear Reactor kegulation Attention:

Mr. Domenic B. Vassallo, Chief Operating Reactors Branch No. 2 Division of Licensing U.S. Nuclear Regulatory Commission Washington, DC 20555

Subject:

Revision to In-Service Testing Relief Requests -

Pump Vibration Testing

Reference:

1) Letter from J. M. Pilant to D. B. Vassallo dated October 19, 1982, " Revision to In-Service Testing Relief Request"

Dear Mr. Vassallo:

Our letter of Reference 1 submitted replacement pages for two In-Service Testing Relief requests. After discussions with the Staff this date, the District is modifying relief request No. RP-04.

Enclosed is the applicable revised page in accordance with the Staff's request.

Should you require additional information relating to this revision, please contact me.

Sincerely, k

Jay M. Pilant Division Manager of Licensing and Quality Assurance JMP:JDW:cmk Enclosure 8211060238 821028 PDR ADOCK 05000298 g{G P

pyg L

Relief Request No.

RP-04 Page 2

of 2

Revision No.

2 TABLE 1 AI.I.0WABLE RANGES OF VIBRATION QUANTITIES V Reference **

Acceptable Alert Required Action (Vr) 0.1 in/sec 0-2Vr (100%)*

>2Vr-4Vr (300%)

>4Vr (>300%)

>.1.2 in/sec 0-1.75Vr (75%)

>l.75Vr-2.5Vr (150%)

>2.5Vr (>l50%)

>.2.3 in/sec 0-1.25Vr (25%)

>l.25Vr-2.0Vr (100%)

>2.0Vr (>100%)

>.3 in/sec 0-1.10Vr (10%)

>1.IVr-1.5Vr (50%)

>.62d in/sec

  • All percentages shown in parentheses are the maximum allowable percents over the original reference value for that particular range.
    • These values are unfiltered.