10 CFR 35.204, Permissible Molybdenum-99, Strontium-82, and Strontium-85 Concentrations

From kanterella
(Redirected from 10 CFR 35.204)
Jump to navigation Jump to search

Permissible molybdenum-99, strontium-82, and strontium-85 concentrations

a

(a) A licensee may not administer to humans a radiopharmaceutical that contains:

(1) More than 0.15 kilobecquerel of molybdenum-99 per megabecquerel of technetium-99m (0.15 microcurie of molybdenum-99 per millicurie of technetium-99m); or
(2) More than 0.02 kilobecquerel of strontium-82 per megabecquerel of rubidium-82 chloride injection (0.02 microcurie of strontium-82 per millicurie of rubidium-82 chloride); or more than 0.2 kilobecquerel of strontium-85 per megabecquerel of rubidium-82 chloride injection (0.2 microcurie of strontium-85 per millicurie of rubidium-82).

b

(b) A licensee that uses molybdenum-99/technetium-99m generators for preparing a technetium-99m radiopharmaceutical shall measure the molybdenum-99 concentration of the first eluate after receipt of a generator to demonstrate compliance with paragraph (a) of this section.

c

(c) A licensee that uses a strontium-82/rubidium-82 generator for preparing a rubidium-82 radiopharmaceutical shall, before the first patient use of the day, measure the concentration of radionuclides strontium-82 and strontium-85 to demonstrate compliance with paragraph (a) of this section.

d

(d) If a licensee is required to measure the molybdenum-99 concentration or strontium-82 and strontium-85 concentrations, the licensee shall retain a record of each measurement in accordance with § 35.2204.

Federal Register

[[[FR::http://frwebgate.access.gpo.gov/cgi-bin/getpage.cgi?dbname=2007_register&page=55932&position=1%7C72 FR 55932 Oct. 1, 2007]]]


External Links

[[URL::http://www.nrc.gov/reading-rm/doc-collections/cfr/part035/part035-0204.html%7CNRC website 10 CFR 35.204]]