| | | Reporting criterion |
|---|
| 05000461/LER-1998-001, :on 970929,failure of Division 2 SR Battery Charger Was Noted.Caused by Deficient Supplier Soldered Connections.Insp of Division 1,2 & 4 SR Battery Chargers Are Complete & Have Been Reworked & Repaired |
- on 970929,failure of Division 2 SR Battery Charger Was Noted.Caused by Deficient Supplier Soldered Connections.Insp of Division 1,2 & 4 SR Battery Chargers Are Complete & Have Been Reworked & Repaired
| 10 CFR 50.73(e)(2)(x) 10 CFR 21.21(d)(3) 10 CFR 50.73(a)(2)(ii)(3) |
| 05000461/LER-1998-002, :on 980123,loss of Svc & Instrument Air Occurred Due to Trip of Operating Air Compressor.Caused by Inadequate Design in Control of Cooling Water Supply to Compressors Lube Oil Coolers.Will Modify Components |
- on 980123,loss of Svc & Instrument Air Occurred Due to Trip of Operating Air Compressor.Caused by Inadequate Design in Control of Cooling Water Supply to Compressors Lube Oil Coolers.Will Modify Components
| 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2)(1) |
| 05000461/LER-1998-003, :on 980213,loss of Nuclear Sys Protection Sys Bus Resulted in Inadvertent Isolation of Shutdown Cooling. Cause Is Unknown.Corrective Actions Not Yet Determined |
- on 980213,loss of Nuclear Sys Protection Sys Bus Resulted in Inadvertent Isolation of Shutdown Cooling. Cause Is Unknown.Corrective Actions Not Yet Determined
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) |
| 05000461/LER-1998-003-01, Forwards LER 98-003-01 & Part 21 Rept 21-98-022,re Loss of Nuclear Sys Protection Sys Bus.Commitments Made within Ltr, Listed | Forwards LER 98-003-01 & Part 21 Rept 21-98-022,re Loss of Nuclear Sys Protection Sys Bus.Commitments Made within Ltr, Listed | |
| 05000461/LER-1998-004-01, Forwards LER 98-004-01 & 10CFR21 Rept 21-98-004/015, Division 2 Nuclear Systems Protection Sys Inverter Not IAW Plants Design Basis Due to Various Deficiencies. Commitments Made by Util,Listed | Forwards LER 98-004-01 & 10CFR21 Rept 21-98-004/015, Division 2 Nuclear Systems Protection Sys Inverter Not IAW Plants Design Basis Due to Various Deficiencies. Commitments Made by Util,Listed | |
| 05000461/LER-1998-004, :on 980127,identified Various Deficiencies in Installed SCR & Power Diodes of Division 2 Nsps Inverter. Caused by Ineffective & Inadequate Preventive Maint. Corrected Deficiencies & Calibr Inverter,Per 10CFR21 |
- on 980127,identified Various Deficiencies in Installed SCR & Power Diodes of Division 2 Nsps Inverter. Caused by Ineffective & Inadequate Preventive Maint. Corrected Deficiencies & Calibr Inverter,Per 10CFR21
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) 10 CFR 21.21(d)(4) 10 CFR 21.21(d)(3) |
| 05000461/LER-1998-005-01, Forwards LER 98-005-01 Re Failure to Verify Closed Pcivs,Per TS Sr.Commitments Made in Rept,Listed | Forwards LER 98-005-01 Re Failure to Verify Closed Pcivs,Per TS Sr.Commitments Made in Rept,Listed | |
| 05000461/LER-1998-006, :on 980131,incorrect Calculation in DG Control Circuitry Results in Insufficient Voltage & Inoperability of Div 1 Dg,Was Discovered.Caused by Initial Error in Calculation.Dg Control Panel Voltage Restored |
- on 980131,incorrect Calculation in DG Control Circuitry Results in Insufficient Voltage & Inoperability of Div 1 Dg,Was Discovered.Caused by Initial Error in Calculation.Dg Control Panel Voltage Restored
| 10 CFR 50.73(a)(2) |
| 05000461/LER-1998-007, :on 980322,inadequate Engineering Evaluation Leads to Installation of Temporary Mod on DC Electrical Power Sys,Was Determined.Caused by Misjudgement & Misassumptions.Improvements Made to 10CFR50.59 SE Process |
- on 980322,inadequate Engineering Evaluation Leads to Installation of Temporary Mod on DC Electrical Power Sys,Was Determined.Caused by Misjudgement & Misassumptions.Improvements Made to 10CFR50.59 SE Process
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(1) |
| 05000461/LER-1998-008, Forwards LER 98-008-00,re Division I Hydrogen & Oxygen Analyzer Incapable of Meeting Design Basis Due to an Excessive Vibration Condition on Air Compressor.Caused by Personnel Error.Commitments Made within Ltr,Listed | Forwards LER 98-008-00,re Division I Hydrogen & Oxygen Analyzer Incapable of Meeting Design Basis Due to an Excessive Vibration Condition on Air Compressor.Caused by Personnel Error.Commitments Made within Ltr,Listed | |
| 05000461/LER-1998-008-01, :on 930213,Division I Hydrogen & Oxygen Analyzer Incapable of Meeting Design Basis Were Noted Due to an Excessive Vibration Condition on Air Compressor.Caused by Personnel Error.Div 1 H202 Air Condition Will Be Corrected |
- on 930213,Division I Hydrogen & Oxygen Analyzer Incapable of Meeting Design Basis Were Noted Due to an Excessive Vibration Condition on Air Compressor.Caused by Personnel Error.Div 1 H202 Air Condition Will Be Corrected
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2)(1) |
| 05000461/LER-1998-009, :on 980203,failure to Account for Design Basis Sys Pressures & Voltages for EDG Air Start Sys Was Noted. Caused by Failure of Design Engineer.Changed Spring Size in Solenoid Valve for Division III EDG Air Start Sys |
- on 980203,failure to Account for Design Basis Sys Pressures & Voltages for EDG Air Start Sys Was Noted. Caused by Failure of Design Engineer.Changed Spring Size in Solenoid Valve for Division III EDG Air Start Sys
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(e)(2)(ii) |
| 05000461/LER-1998-010, :on 971217,Divs 1 & 2 H & Oxygen Analyzers Were Declared Inoperable Due to Inadequate Commercial Grade Dedication of safety-related Replacement Parts by Supplier. Evaluated Installed Parts for Acceptability |
- on 971217,Divs 1 & 2 H & Oxygen Analyzers Were Declared Inoperable Due to Inadequate Commercial Grade Dedication of safety-related Replacement Parts by Supplier. Evaluated Installed Parts for Acceptability
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) 10 CFR 21.21(d)(4) 10 CFR 21.21(d)(3) |
| 05000461/LER-1998-011, :on 980312,CR Ventilation Sys Was Declared Inoperable Due to Broken/Missing Conduit Hold Down Restraints on VC Chiller Skids.Caused by Personnel Walking on Equipment.Generated Work Requests |
- on 980312,CR Ventilation Sys Was Declared Inoperable Due to Broken/Missing Conduit Hold Down Restraints on VC Chiller Skids.Caused by Personnel Walking on Equipment.Generated Work Requests
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) |
| 05000461/LER-1998-012, Forwards LER 98-012-00, High Differential Pressure Required to Close Excess Flow Check Valves Results in Valves Being Outside of Design Basis of Plant, IAW Requirements of 10CFR50.73 | Forwards LER 98-012-00, High Differential Pressure Required to Close Excess Flow Check Valves Results in Valves Being Outside of Design Basis of Plant, IAW Requirements of 10CFR50.73 | 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(1) |
| 05000461/LER-1998-013-01, Forwards LER 98-013-01, Remote Shutdown Panel Operation of Rcics May Be Prevented Following MCR Fire,Due to Supplier Design Lacking Circuit Isolation & 10CFR21 Rept Number 21-98-026.Without Part 21 Rept | Forwards LER 98-013-01, Remote Shutdown Panel Operation of Rcics May Be Prevented Following MCR Fire,Due to Supplier Design Lacking Circuit Isolation & 10CFR21 Rept Number 21-98-026.Without Part 21 Rept | |
| 05000461/LER-1998-014-01, Design Failure Analysis for FW Piping Does Not Match Fatigue Analysis for FW Nozzles Resulting in Condition Outside of Design Basis for Plant, Has Been Cancelled | Design Failure Analysis for FW Piping Does Not Match Fatigue Analysis for FW Nozzles Resulting in Condition Outside of Design Basis for Plant, Has Been Cancelled | |
| 05000461/LER-1998-014, :on 980325,design Fatigue Analysis for FW Piping Does Not Match Fatigue Analysis for FW Nozzles, Resulting in Condition,Outside Design Basis of Plant Occurred.Cause & Corrective Action,Not Yet Been Determined |
- on 980325,design Fatigue Analysis for FW Piping Does Not Match Fatigue Analysis for FW Nozzles, Resulting in Condition,Outside Design Basis of Plant Occurred.Cause & Corrective Action,Not Yet Been Determined
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) |
| 05000461/LER-1998-015, :on 980405,ESF Actuation Was Noted.Caused by Shorted Diode in Nsps.Replaced Shorted Blocking Diode & Tested Other Diodes for Defects |
- on 980405,ESF Actuation Was Noted.Caused by Shorted Diode in Nsps.Replaced Shorted Blocking Diode & Tested Other Diodes for Defects
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000461/LER-1998-016, :on 870630,failure to Test Valves 1SX013D/E/F IAW IST Program Was Noted.Caused by Personnel Error.Tested Safety Functions of Valves 1SX012D/E/F & Added Valves to IST |
- on 870630,failure to Test Valves 1SX013D/E/F IAW IST Program Was Noted.Caused by Personnel Error.Tested Safety Functions of Valves 1SX012D/E/F & Added Valves to IST
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications |
| 05000461/LER-1998-017, :on 980402,inadequate Implementation of SR Was Noted.Caused by Misinterpretation of TS SR 3.8.6.2 & Table 3.8.6-1.Revised Procedure for Performing Battery Cell Specific Gravity Checks |
- on 980402,inadequate Implementation of SR Was Noted.Caused by Misinterpretation of TS SR 3.8.6.2 & Table 3.8.6-1.Revised Procedure for Performing Battery Cell Specific Gravity Checks
| 10 CFR 50.73(a)(2)(1) |
| 05000461/LER-1998-018, :on 980416,ESFA,occurred.Caused by Deficiencies in Method Used to Perform Nsps Power Supply Adjustment. Developed Maint Procedure for Replacement of Power Supplies Powered by Nsps Bus |
- on 980416,ESFA,occurred.Caused by Deficiencies in Method Used to Perform Nsps Power Supply Adjustment. Developed Maint Procedure for Replacement of Power Supplies Powered by Nsps Bus
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000461/LER-1998-019, :on 980417,noted Failure to Satisfy TS for Ensuring That Electrical Loads Properly Sequence Onto safety-related Buses.Caused by Inadequate Surveillance Procedures.Will Revise Procedures 9080.21 & 9080.22 |
- on 980417,noted Failure to Satisfy TS for Ensuring That Electrical Loads Properly Sequence Onto safety-related Buses.Caused by Inadequate Surveillance Procedures.Will Revise Procedures 9080.21 & 9080.22
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2)(1) |
| 05000461/LER-1998-020, :on 980609,discovered Flow Gauge in Main CR to Be Reading Greater than Instrument Range.Cause Indeterminate.Will Incorporate Event Info Into Operator Training Program & Verified Calibr of Flow Instrumentation |
- on 980609,discovered Flow Gauge in Main CR to Be Reading Greater than Instrument Range.Cause Indeterminate.Will Incorporate Event Info Into Operator Training Program & Verified Calibr of Flow Instrumentation
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) |
| 05000461/LER-1998-020-01, Forwards LER 98-020-01, Inadequate Flow Balancing of Shutdown SWS Results in Less than Required Flow to SWS Loads. Revised LER Provides Cause of Event & Corrective Actions | Forwards LER 98-020-01, Inadequate Flow Balancing of Shutdown SWS Results in Less than Required Flow to SWS Loads. Revised LER Provides Cause of Event & Corrective Actions | |
| 05000461/LER-1998-021, :on 980220,cracks in Medium & High Density Silicone Penetration Seals Were Not Per Design Basis.Caused by Design Error.Inspected Potentially Affected Seals & Repaired Seals as Necessary |
- on 980220,cracks in Medium & High Density Silicone Penetration Seals Were Not Per Design Basis.Caused by Design Error.Inspected Potentially Affected Seals & Repaired Seals as Necessary
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) |
| 05000461/LER-1998-022, :on 980729,discovered That Surveillance Testing of Div 2 DG Fuel Oil Transfer Pump & Div 2 DG Fuel Oil Storage Tank Had Not Been Performed.Caused by Data Input Error.Will Update & Verify Completion Dates in Database |
- on 980729,discovered That Surveillance Testing of Div 2 DG Fuel Oil Transfer Pump & Div 2 DG Fuel Oil Storage Tank Had Not Been Performed.Caused by Data Input Error.Will Update & Verify Completion Dates in Database
| 10 CFR 50.73(a)(2)(1) |
| 05000461/LER-1998-023, :on 980626,determined That TS SR 3.8.1.17 for Division 3 DG Which Verifies ready-to-load Following Receipt of ECCS Signal,Was Not Adequately Satisfied.Cause & Corrective Actions Will Be Provided in Revised LER |
- on 980626,determined That TS SR 3.8.1.17 for Division 3 DG Which Verifies ready-to-load Following Receipt of ECCS Signal,Was Not Adequately Satisfied.Cause & Corrective Actions Will Be Provided in Revised LER
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2)(1) |
| 05000461/LER-1998-024-01, Forwards LER 98-024-01,re Failure to Perform Surveillance Testing on Div II 4.16 Kv Bus Uvr within Specified Frequency.Commitments Listed | Forwards LER 98-024-01,re Failure to Perform Surveillance Testing on Div II 4.16 Kv Bus Uvr within Specified Frequency.Commitments Listed | |
| 05000461/LER-1998-024, :on 980708,failure to Perform Surveillance Testing on Div II Voltage Relays within Specified Frequency of TS Was Noted.Cause of Event Is Under Investigation.Util Expects to Issue Rev to Rept by 980907 |
- on 980708,failure to Perform Surveillance Testing on Div II Voltage Relays within Specified Frequency of TS Was Noted.Cause of Event Is Under Investigation.Util Expects to Issue Rev to Rept by 980907
| 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) |
| 05000461/LER-1998-025, :on 860929,repeated Failures of Switchgear Heat Removal Condenser Gasket Occurred.Caused by Inadequate Design Consideration of Pressure Transient Effects of Shutdown SWS Components.Installed blow-out Resistant Gasket |
- on 860929,repeated Failures of Switchgear Heat Removal Condenser Gasket Occurred.Caused by Inadequate Design Consideration of Pressure Transient Effects of Shutdown SWS Components.Installed blow-out Resistant Gasket
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition |
| 05000461/LER-1998-026, :on 860929,inoperable EP Assembly Circuit Cards Which Monitor Power to RPS Scarm & MSIV Sv Were Noted.Caused by Improper Design of EP Assembly Circuit Cards by Supplier. Procured & Installed Correctly Designed Circuit Cards |
- on 860929,inoperable EP Assembly Circuit Cards Which Monitor Power to RPS Scarm & MSIV Sv Were Noted.Caused by Improper Design of EP Assembly Circuit Cards by Supplier. Procured & Installed Correctly Designed Circuit Cards
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000461/LER-1998-027, :on 980918,failure to Perform Surveillance Testing on Div II 4.16 Bus Uvr within Specified Frequency Was Noted.Caused by Inadequate Software Change Mgt.Performed Testing on Div II 4.16 Kv Bus Uvr |
- on 980918,failure to Perform Surveillance Testing on Div II 4.16 Bus Uvr within Specified Frequency Was Noted.Caused by Inadequate Software Change Mgt.Performed Testing on Div II 4.16 Kv Bus Uvr
| 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000461/LER-1998-028, :on 981205,thermal Induced Pressure Locking of SR Power Operated Gate Valves Was Noted.Caused by Inadequate Initial Design.Evaluated GL 95-07 Valves for Susceptibility to Thermal Induced Pressure Locking |
- on 981205,thermal Induced Pressure Locking of SR Power Operated Gate Valves Was Noted.Caused by Inadequate Initial Design.Evaluated GL 95-07 Valves for Susceptibility to Thermal Induced Pressure Locking
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) |
| 05000461/LER-1998-029, :on 860929,discovered That Conductors in Two Containment Electrical Penetrations Did Not Have Adequate Overcurrent Protection.Caused by Original Design Error for Plant.Will Design & Install Required Protective Devices |
- on 860929,discovered That Conductors in Two Containment Electrical Penetrations Did Not Have Adequate Overcurrent Protection.Caused by Original Design Error for Plant.Will Design & Install Required Protective Devices
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) |
| 05000461/LER-1998-030-01, Insufficient Suppression Pool Makeup Volume to Meet Design Basis Suppression Pool Level Requirements Following LOCA, Has Been Cancelled | Insufficient Suppression Pool Makeup Volume to Meet Design Basis Suppression Pool Level Requirements Following LOCA, Has Been Cancelled | |
| 05000461/LER-1998-030, :on 980828,insufficient Sp Makeup Vol to Meet Design Basis Sp Level Requirements Following LOCA Was Noted. Cause of Event Is Under Investigation.Corrective Actions to Event Are Pending Outcome of Investigation |
- on 980828,insufficient Sp Makeup Vol to Meet Design Basis Sp Level Requirements Following LOCA Was Noted. Cause of Event Is Under Investigation.Corrective Actions to Event Are Pending Outcome of Investigation
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) |
| 05000461/LER-1998-031, :on 860929,SP Did Not Adequately Consider Accuracy of Installed Instrumentation in Meeting TS Requirements for DG Loading.Caused by Lack of Rigor in Documentation of Evaluations.Reviewed TS SR Parameters |
- on 860929,SP Did Not Adequately Consider Accuracy of Installed Instrumentation in Meeting TS Requirements for DG Loading.Caused by Lack of Rigor in Documentation of Evaluations.Reviewed TS SR Parameters
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2)(1) |
| 05000461/LER-1998-032, :on 980929,noted That Excessive Voltage Drop in Control Circuit for Division 3 Diesel Output Circuit Breaker Could Result in Plant Being Outside Design Basis.Caused by Inadequate Design.Prepared Design Change of Control Circuit |
- on 980929,noted That Excessive Voltage Drop in Control Circuit for Division 3 Diesel Output Circuit Breaker Could Result in Plant Being Outside Design Basis.Caused by Inadequate Design.Prepared Design Change of Control Circuit
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v), Loss of Safety Function |
| 05000461/LER-1998-033, :on 981007,inappropriate Clearing of Caution Tagout Resulted in Improved TS LCO 3.4.10 Action A.1 Not Being Met.Caused by Tunnel Vision & Inattention to Detail. New Caution Tagout for Div 2 Shutdown Svc Water,Established |
- on 981007,inappropriate Clearing of Caution Tagout Resulted in Improved TS LCO 3.4.10 Action A.1 Not Being Met.Caused by Tunnel Vision & Inattention to Detail. New Caution Tagout for Div 2 Shutdown Svc Water,Established
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000461/LER-1998-035, :on 981016,failure to Comply with TS Action Requirements to Immediately Restore AC & DC Electrical Power Sources,Was Discovered.Caused by Inadequate Communications. LCO Tracking Database for Daily Rept Will Be Revised |
- on 981016,failure to Comply with TS Action Requirements to Immediately Restore AC & DC Electrical Power Sources,Was Discovered.Caused by Inadequate Communications. LCO Tracking Database for Daily Rept Will Be Revised
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2)(1) |
| 05000461/LER-1998-036-01, Forwards LER 98-036-01,re Opening Incorrect Electrical Cubicle,Causing Loss of SD Cooling & Leading to Failure to Meet TS Required Action in Required Time.Encl Rept Contains Listed Commitments | Forwards LER 98-036-01,re Opening Incorrect Electrical Cubicle,Causing Loss of SD Cooling & Leading to Failure to Meet TS Required Action in Required Time.Encl Rept Contains Listed Commitments | |
| 05000461/LER-1998-037, :on 981215,identified That SR 3.3.3.1.2,which Requires Channel Calibr of Drywell & Primary Containment Hydrogen & Oxygen Analyzers Not Properly Implemented.Caused by Lack of Info Validation & Verification.Procedure Revised |
- on 981215,identified That SR 3.3.3.1.2,which Requires Channel Calibr of Drywell & Primary Containment Hydrogen & Oxygen Analyzers Not Properly Implemented.Caused by Lack of Info Validation & Verification.Procedure Revised
| 10 CFR 50.73(a)(2)(1) |