| | | Reporting criterion |
|---|
| 05000322/LER-1985-001, :on 841223,during Fuel Loading Operation, Reactor Protection Sys Actuated.Caused by Upscale Trip on Channel FLC a of Fuel Load Chambers Due to Electrical Noise Interference.Channel Replaced |
- on 841223,during Fuel Loading Operation, Reactor Protection Sys Actuated.Caused by Upscale Trip on Channel FLC a of Fuel Load Chambers Due to Electrical Noise Interference.Channel Replaced
| |
| 05000322/LER-1985-003, :on 850104,discrepancy Between Requirements to Maintain Fire Watches & to Remove People from Area Reconciled.Subsequent Review W/Nrc Brought About Slight Changes in Procedures Re Fire Watches |
- on 850104,discrepancy Between Requirements to Maintain Fire Watches & to Remove People from Area Reconciled.Subsequent Review W/Nrc Brought About Slight Changes in Procedures Re Fire Watches
| |
| 05000322/LER-1985-004, :on 850108,continuous Fire Watch Not Posted in Relay Room During Fuel Loading.Fire Watches in Area Where Operable Redundant Equipment Required During Fire Instated on 850108 |
- on 850108,continuous Fire Watch Not Posted in Relay Room During Fuel Loading.Fire Watches in Area Where Operable Redundant Equipment Required During Fire Instated on 850108
| |
| 05000322/LER-1985-005, :on 850108,reactor Protection Sys Actuation Occurred.Caused by Technician Inadvertently Connecting Test Equipment to source-range Monitor a Preamplifier.Procedures Reviewed |
- on 850108,reactor Protection Sys Actuation Occurred.Caused by Technician Inadvertently Connecting Test Equipment to source-range Monitor a Preamplifier.Procedures Reviewed
| |
| 05000322/LER-1985-006, :on 850204,valving in Reactor Pressure Transmitter for Remote Shutdown Panel Caused Transient in Ref Leg of Instrument.Technicians Cautioned Re Valve Manipulations on Reactor Pressure Vessel Leg |
- on 850204,valving in Reactor Pressure Transmitter for Remote Shutdown Panel Caused Transient in Ref Leg of Instrument.Technicians Cautioned Re Valve Manipulations on Reactor Pressure Vessel Leg
| |
| 05000322/LER-1985-007, :on 850204,hourly Fire Watches Not Completed within Hourly Basis.Control Room Personnel Assigned to Perform Fire Watches Concurrent W/Other Duties.Watches Reassigned to Personnel W/No Other Duties |
- on 850204,hourly Fire Watches Not Completed within Hourly Basis.Control Room Personnel Assigned to Perform Fire Watches Concurrent W/Other Duties.Watches Reassigned to Personnel W/No Other Duties
| |
| 05000322/LER-1985-008, :on 850227,emergency Diesel Generator 103 Automatically Started.Caused by Technician Error Coincident W/Reset of Ground Alarm Relay Tripping During Surveillance Procedure |
- on 850227,emergency Diesel Generator 103 Automatically Started.Caused by Technician Error Coincident W/Reset of Ground Alarm Relay Tripping During Surveillance Procedure
| |
| 05000322/LER-1985-008-01, :on 850227,emergency Diesel Generator 103 Automatically Started Due to Tripping of Undervoltage Lockout Relay.Caused by Personnel Error.Generator Secured & Lineup Restored |
- on 850227,emergency Diesel Generator 103 Automatically Started Due to Tripping of Undervoltage Lockout Relay.Caused by Personnel Error.Generator Secured & Lineup Restored
| |
| 05000322/LER-1985-009, :on 850305,reactor Water Cleanup Sys Inadvertently Isolated.Caused by Contact of Two Leads During post-work Logic Circuit Testing on Steam Leak Detection Sys. Testing Resumed & Completed W/O Incident |
- on 850305,reactor Water Cleanup Sys Inadvertently Isolated.Caused by Contact of Two Leads During post-work Logic Circuit Testing on Steam Leak Detection Sys. Testing Resumed & Completed W/O Incident
| |
| 05000322/LER-1985-010, :on 850310,while Pressurizing Reactor Vessel for Backflushing Crds,Inadvertent Isolation of RHR Sys Occurred.Caused by Exceeding High Suction Pressure Setpoint. Procedures Being Revised |
- on 850310,while Pressurizing Reactor Vessel for Backflushing Crds,Inadvertent Isolation of RHR Sys Occurred.Caused by Exceeding High Suction Pressure Setpoint. Procedures Being Revised
| |
| 05000322/LER-1985-011, :on 850315,control Room Air Conditioning Sys Automatic Initiation Occurred.Caused by Differential Pressure Decrease Due to Simultaneous Opening of Two Doors. Signs Posted |
- on 850315,control Room Air Conditioning Sys Automatic Initiation Occurred.Caused by Differential Pressure Decrease Due to Simultaneous Opening of Two Doors. Signs Posted
| |
| 05000322/LER-1985-013, :on 850407,failure of HPCI Circuit Inverter Rendered HPCI Sys Inoperable.Caused by Failure of Cooling Fan Causing Inverter Cabinet & Circuitry to Overheat. Procedures for Fan Insp Will Be Revised |
- on 850407,failure of HPCI Circuit Inverter Rendered HPCI Sys Inoperable.Caused by Failure of Cooling Fan Causing Inverter Cabinet & Circuitry to Overheat. Procedures for Fan Insp Will Be Revised
| |
| 05000322/LER-1985-014, :on 850408,hourly Firewatch Patrol,Required by Tech Specs,Late by 10 Minutes for Emergency Diesel Generator Rooms.Caused by Computer Malfunction Which Denied Access to Rooms.Security Summoned to Permit Access |
- on 850408,hourly Firewatch Patrol,Required by Tech Specs,Late by 10 Minutes for Emergency Diesel Generator Rooms.Caused by Computer Malfunction Which Denied Access to Rooms.Security Summoned to Permit Access
| |
| 05000322/LER-1985-015, :on 850405,results of Annual Sounding of Intake Canal Indicated Bottom Depth Above Tech Spec Limit.Caused by Normal Sediment Deposition.Dredging Completion Expected by 850730 |
- on 850405,results of Annual Sounding of Intake Canal Indicated Bottom Depth Above Tech Spec Limit.Caused by Normal Sediment Deposition.Dredging Completion Expected by 850730
| |
| 05000322/LER-1985-016, :on 850413,automatic Initiation of Control Room Air Conditioning Occurred.Caused by Fluctuations in Secondary Containment Pressure Resulting from Normal Usage of Airlocks Leading Into Reactor Bldg |
- on 850413,automatic Initiation of Control Room Air Conditioning Occurred.Caused by Fluctuations in Secondary Containment Pressure Resulting from Normal Usage of Airlocks Leading Into Reactor Bldg
| |
| 05000322/LER-1985-017, :on 850429,two Scrams & One Half NS4 Isolation Initiated Due to Pressure Oscillations in Reactor Pressure Vessel Level Ref Leg.Caused by Performance of MSIV Leakage Control Surveillance Test |
- on 850429,two Scrams & One Half NS4 Isolation Initiated Due to Pressure Oscillations in Reactor Pressure Vessel Level Ref Leg.Caused by Performance of MSIV Leakage Control Surveillance Test
| |
| 05000322/LER-1985-018, :on 850509,reactor Protection Sys Actuation Occurred Due to False High Flux Signal Causing Upscale Spike on Intermediate Range Monitor Channel D.Caused by Personnel Bumping in-core Instrument Cables |
- on 850509,reactor Protection Sys Actuation Occurred Due to False High Flux Signal Causing Upscale Spike on Intermediate Range Monitor Channel D.Caused by Personnel Bumping in-core Instrument Cables
| |
| 05000322/LER-1985-019, :on 850516,temporary Procedure Change Notice Re Clarification of Procedure 24.602.01 (Intermediate Range Monitor Functional Test) Not Reviewed & Approved within Required Time Frame.Log Will Be Reviewed Daily |
- on 850516,temporary Procedure Change Notice Re Clarification of Procedure 24.602.01 (Intermediate Range Monitor Functional Test) Not Reviewed & Approved within Required Time Frame.Log Will Be Reviewed Daily
| |
| 05000322/LER-1985-020, :on 850521,full Scram & one-half NS4 Isolation Initiated.Caused by Pressure Transient in Common Variable Leg That Occurred When High Pressure Header Isolation Valve for Level Transmitter 1B21*LT159B Opened |
- on 850521,full Scram & one-half NS4 Isolation Initiated.Caused by Pressure Transient in Common Variable Leg That Occurred When High Pressure Header Isolation Valve for Level Transmitter 1B21*LT159B Opened
| |
| 05000322/LER-1985-021, :on 850615,bomb Threat Received Over 911 Telephone Number from Unidentified Individual Stating Device Placed in Containment Bldg.Security Alert Declared & Site Evacuated.No Explosive Device Found |
- on 850615,bomb Threat Received Over 911 Telephone Number from Unidentified Individual Stating Device Placed in Containment Bldg.Security Alert Declared & Site Evacuated.No Explosive Device Found
| |
| 05000322/LER-1985-022, :on 850606,reactor Protection Sys Actuation Occurred.Caused by Increase in Reactor Pressure Vessel Pressure Above High Pressure Scram Trip Setpoint.Valve Positioner Adjusted |
- on 850606,reactor Protection Sys Actuation Occurred.Caused by Increase in Reactor Pressure Vessel Pressure Above High Pressure Scram Trip Setpoint.Valve Positioner Adjusted
| |
| 05000322/LER-1985-023, :on 850611 & 21,high Steam Leak Detection Signals Caused Three Unplanned Isolations of Reactor Water Cleanup Sys Outboard Isolation Valve.Caused by electro- Magnetic Interference.Testing to Be Performed |
- on 850611 & 21,high Steam Leak Detection Signals Caused Three Unplanned Isolations of Reactor Water Cleanup Sys Outboard Isolation Valve.Caused by electro- Magnetic Interference.Testing to Be Performed
| |
| 05000322/LER-1985-024, :on 850713,reactor Scrammed on Low Water Level During Securing of Condensate Booster Pump After Min Flow Control Valve Failed Shut.Valve Failure Caused by Sheared Instrument Air Line.Line Repaired |
- on 850713,reactor Scrammed on Low Water Level During Securing of Condensate Booster Pump After Min Flow Control Valve Failed Shut.Valve Failure Caused by Sheared Instrument Air Line.Line Repaired
| |
| 05000322/LER-1985-025, :on 850706,Temporary Mod Tm 85-03-010 to Steam Air Ejector Radiation Elements Made in Mar 1985 Discovered Improperly Implemented.Cause Not Stated.Mod Revised to Include Checklist for Temporary Mod Review |
- on 850706,Temporary Mod Tm 85-03-010 to Steam Air Ejector Radiation Elements Made in Mar 1985 Discovered Improperly Implemented.Cause Not Stated.Mod Revised to Include Checklist for Temporary Mod Review
| |
| 05000322/LER-1985-026, :on 850713,during Surveillance Leak Test of Primary Containment Personnel Hatch,Leakage Rate Found in Excess of Tech Spec Limit.Caused by Weak Seating of Manual Valve to Door Interlock Pressure Switch |
- on 850713,during Surveillance Leak Test of Primary Containment Personnel Hatch,Leakage Rate Found in Excess of Tech Spec Limit.Caused by Weak Seating of Manual Valve to Door Interlock Pressure Switch
| |
| 05000322/LER-1985-027, :on 850716,reactor Water Cleanup Outboard Isolation Valve Isolated.Caused by Erroneous High Differential Flow Signal Due to Blown Fuse.Fuse Replaced & Associated Instrument Calibr Verified |
- on 850716,reactor Water Cleanup Outboard Isolation Valve Isolated.Caused by Erroneous High Differential Flow Signal Due to Blown Fuse.Fuse Replaced & Associated Instrument Calibr Verified
| |
| 05000322/LER-1985-028, :on 850718,malfunctioning Door Prevented Access to HVAC & Chiller Rooms W/Plant in Operational Condition 4 & All Control Rods Inserted.Door Forced Open.Damaged Door Latch Mechanism Repaired |
- on 850718,malfunctioning Door Prevented Access to HVAC & Chiller Rooms W/Plant in Operational Condition 4 & All Control Rods Inserted.Door Forced Open.Damaged Door Latch Mechanism Repaired
| |
| 05000322/LER-1985-030, :on 850725,control Room Air Conditioning Sys Side a & Reactor Bldg Standby Ventilation Sys Side a Automatic Initiation Occurred.Caused by Loss of Voltage in Initiating Circuit |
- on 850725,control Room Air Conditioning Sys Side a & Reactor Bldg Standby Ventilation Sys Side a Automatic Initiation Occurred.Caused by Loss of Voltage in Initiating Circuit
| |
| 05000322/LER-1985-031, :on 850726,low Reactor Water Level Caused Reactor Protection Sys Actuation.Caused by Operator Opening RHR Suppression Pool Suction Valve Before Associated Shutdown Cooling Valve Closed |
- on 850726,low Reactor Water Level Caused Reactor Protection Sys Actuation.Caused by Operator Opening RHR Suppression Pool Suction Valve Before Associated Shutdown Cooling Valve Closed
| |
| 05000322/LER-1985-032, :on 850822,HPCI Turbine Exhaust Diaphragm High Pressure Side B Signal Initiated Causing HPCI Sys Isolation. Caused by Leak in Diaphragm W/Buildup of Water in Sensing Lines.Rupture Disk Replaced |
- on 850822,HPCI Turbine Exhaust Diaphragm High Pressure Side B Signal Initiated Causing HPCI Sys Isolation. Caused by Leak in Diaphragm W/Buildup of Water in Sensing Lines.Rupture Disk Replaced
| |
| 05000322/LER-1985-033, :on 850825,inadvertent Split of Reactor Bldg Closed Loop Cooling Water Into Accident Mode Occurred.Caused by Personnel Error Due to Reproductive Quality of Drawing. Drawings Reviewed for Clarity |
- on 850825,inadvertent Split of Reactor Bldg Closed Loop Cooling Water Into Accident Mode Occurred.Caused by Personnel Error Due to Reproductive Quality of Drawing. Drawings Reviewed for Clarity
| |
| 05000322/LER-1985-034, :on 850828,hinged Cap on Svc Water Standpipe Found Wedged Shut.Cause Unknown.Wedge & Temporary Scaffolding Removed to Prevent Immediate Access to Standpipe |
- on 850828,hinged Cap on Svc Water Standpipe Found Wedged Shut.Cause Unknown.Wedge & Temporary Scaffolding Removed to Prevent Immediate Access to Standpipe
| |
| 05000322/LER-1985-035, :on 850831,operator Manually Initiated Reactor Protection Sys After Receiving Scram Pilot Valve Air Header Pressure Low & Control Rod Drift Alarms.Caused by Clogging of Instrument Air Dryer Afterfilter |
- on 850831,operator Manually Initiated Reactor Protection Sys After Receiving Scram Pilot Valve Air Header Pressure Low & Control Rod Drift Alarms.Caused by Clogging of Instrument Air Dryer Afterfilter
| |
| 05000322/LER-1985-037, :on 850906,low Level 3 Scram Occurred.Caused by Technician Valving Transmitter Back Into Svc & Not Detecting Pressure Perturbation Traveling Through Instrument Line to Variable Leg.Info Tags Hung on Instruments |
- on 850906,low Level 3 Scram Occurred.Caused by Technician Valving Transmitter Back Into Svc & Not Detecting Pressure Perturbation Traveling Through Instrument Line to Variable Leg.Info Tags Hung on Instruments
| |
| 05000322/LER-1985-038, :on 850908,water Level Indicator Associated W/Ref Leg B Read High & Diverged from Water Level Indicators Associated W/Ref Leg A.Caused by Excess Condensate Accumulation in Steam Line |
- on 850908,water Level Indicator Associated W/Ref Leg B Read High & Diverged from Water Level Indicators Associated W/Ref Leg A.Caused by Excess Condensate Accumulation in Steam Line
| |
| 05000322/LER-1985-039, :on 850909 & 18,while Performing Surveillance Procedure on Reactor Bldg Standby Ventilation Sys Filter Trains,Control Room Air Conditioning Initiations Occurred Due to Low Differential Pressure Condition |
- on 850909 & 18,while Performing Surveillance Procedure on Reactor Bldg Standby Ventilation Sys Filter Trains,Control Room Air Conditioning Initiations Occurred Due to Low Differential Pressure Condition
| |
| 05000322/LER-1985-040, :on 850909,reactor Bldg Standby Ventilation Sys/Control Room Air Conditioning Initiation Occurred Due to Undervoltage Condition.Caused by Decrease in 138-kV Offsite Power Due to Lightning Storm |
- on 850909,reactor Bldg Standby Ventilation Sys/Control Room Air Conditioning Initiation Occurred Due to Undervoltage Condition.Caused by Decrease in 138-kV Offsite Power Due to Lightning Storm
| |
| 05000322/LER-1985-042, :on 850912,low Level Reactor Trip Occurred During Operational Condition 2.Caused by Operator Opening & Closing Test Valve,Producing Pressure Oscillation in Narrow Range Variable Leg A.Operator Counseled |
- on 850912,low Level Reactor Trip Occurred During Operational Condition 2.Caused by Operator Opening & Closing Test Valve,Producing Pressure Oscillation in Narrow Range Variable Leg A.Operator Counseled
| |
| 05000322/LER-1985-043, :on 850917,full Reactor Trip Occurred Due to Low Level Signal.Caused by Hydraulic Oscillation When Instrument Test Equipment Valved In.Procedures to Be Revised |
- on 850917,full Reactor Trip Occurred Due to Low Level Signal.Caused by Hydraulic Oscillation When Instrument Test Equipment Valved In.Procedures to Be Revised
| |
| 05000322/LER-1985-044, :on 850920,reactor Water Cleanup Isolation Occurred.Caused by Personnel Error.Sys Replaced in Svc. Incident Reviewed W/Personnel Involved.Walkdown Completed. Several Panels Examined |
- on 850920,reactor Water Cleanup Isolation Occurred.Caused by Personnel Error.Sys Replaced in Svc. Incident Reviewed W/Personnel Involved.Walkdown Completed. Several Panels Examined
| |
| 05000322/LER-1985-045, :on 850925,Loop B of LPCI Sys of RHR Sys Declared Inoperable.Possibly Caused by Min Flow Control Valve Vibration Due to Cavitation in Suppression Pool Test Return Line.Studies Being Performed |
- on 850925,Loop B of LPCI Sys of RHR Sys Declared Inoperable.Possibly Caused by Min Flow Control Valve Vibration Due to Cavitation in Suppression Pool Test Return Line.Studies Being Performed
| |
| 05000322/LER-1985-046, :on 850927,ESF Actuations Occurred Due to Spiking Low Voltage Conditions on 138-kV Transmission Sys & Fire Watches Suspended.Caused by Hurricane Gloria.Sys Reset & Fire Watch Resumed |
- on 850927,ESF Actuations Occurred Due to Spiking Low Voltage Conditions on 138-kV Transmission Sys & Fire Watches Suspended.Caused by Hurricane Gloria.Sys Reset & Fire Watch Resumed
| |
| 05000322/LER-1985-046-01, :on 850925,LPCI Sys Loop B of RHR Sys Declared Inoperable While HPCI Sys Out of Svc Due to Testing.Caused by Valve Vibration Due to Cavitation in Suppression Pool Test Return Line |
- on 850925,LPCI Sys Loop B of RHR Sys Declared Inoperable While HPCI Sys Out of Svc Due to Testing.Caused by Valve Vibration Due to Cavitation in Suppression Pool Test Return Line
| |
| 05000322/LER-1985-047, :on 850930,emergency Diesel Generator 103 auto-started Due to Undervoltage Condition.Caused by Personnel Error.Diesel Secured & Reprimand Issued to Responsible Individual |
- on 850930,emergency Diesel Generator 103 auto-started Due to Undervoltage Condition.Caused by Personnel Error.Diesel Secured & Reprimand Issued to Responsible Individual
| |
| 05000322/LER-1985-048, :on 851009,reactor Bldg Standby Ventilation Sys Side B Initiation Occurred.Caused by Technician Error in Opening Breaker.Incident Discussed W/Technician Re Proper Way to Deenergize Circuits |
- on 851009,reactor Bldg Standby Ventilation Sys Side B Initiation Occurred.Caused by Technician Error in Opening Breaker.Incident Discussed W/Technician Re Proper Way to Deenergize Circuits
| |
| 05000322/LER-1985-050, :on 851102,during Surveillance Procedure, Reactor Bldg Standby Ventilation/Control Room Air Conditioning Sys Side B Initiated.Caused by Technician Error.Sys Reset & Technician Counseled |
- on 851102,during Surveillance Procedure, Reactor Bldg Standby Ventilation/Control Room Air Conditioning Sys Side B Initiated.Caused by Technician Error.Sys Reset & Technician Counseled
| |
| 05000322/LER-1985-052, :on 851104,full Reactor Trip & Full Nuclear Steam Supply Shutoff Sys Isolation Occurred.Caused by Power Source Select Switch (S-1) Overtraveling Beyond Norm Position.Trip Reset & Switch Examined |
- on 851104,full Reactor Trip & Full Nuclear Steam Supply Shutoff Sys Isolation Occurred.Caused by Power Source Select Switch (S-1) Overtraveling Beyond Norm Position.Trip Reset & Switch Examined
| |
| 05000322/LER-1985-053, :on 851107,w/mode Switch in Shutdown & All Rods Inserted in Core,Determination Made That Temporary Procedure Change Notice Not Approved by Plant Manager within 14 Days. Notices Will Be Administratively Expedited |
- on 851107,w/mode Switch in Shutdown & All Rods Inserted in Core,Determination Made That Temporary Procedure Change Notice Not Approved by Plant Manager within 14 Days. Notices Will Be Administratively Expedited
| |
| 05000322/LER-1985-054, :on 851112,during Operational Condition 5, 1/2-reactor trip,1/2-nuclear Steam Supply Shutoff Sys Isolation & Reactor Bldg Standby Ventilation Sys Initiation Signal Occurred.Caused by Operator Error |
- on 851112,during Operational Condition 5, 1/2-reactor trip,1/2-nuclear Steam Supply Shutoff Sys Isolation & Reactor Bldg Standby Ventilation Sys Initiation Signal Occurred.Caused by Operator Error
| |
| 05000322/LER-1985-055, :on 851130,all Electrical Equipment Not Environmentally Qualified Removed from Plant.Two High Radiation Detectors Returned to Vendor.High Radiation Monitor Cable Assembly Checked Out |
- on 851130,all Electrical Equipment Not Environmentally Qualified Removed from Plant.Two High Radiation Detectors Returned to Vendor.High Radiation Monitor Cable Assembly Checked Out
| |