Licensee Event Report 80-059/03L-0 Attached please find Licensee Event Report 80-059/03L-0 concerning the E=ergency Diesel Generator DF-X-1A Trip on December 26, 1980.

l This event concerns Section 3.8.1.1 and is considered reportable under l

Section 6.9.1.9(b) of the Interim Recovery Technical Specifications.

Sincerely, i

7 i

or c

G. K. Hovey Vice-President and Director, TMI-2 GKH:SDC:djb Attach =ents cc:

L. Barrett, Deputy Program Director B. J. Snyder, Program Director-TMI Office

(

,,oh,

'$t O

Nb y

I Metreochtan Ecson Comcany is a Memeer of me General Puche Ut;htaes System