A violation was identified for the licensee's failure to implement adequate corrective actions to effectively address a previous Red finding and preclude recurrence (Inspection Report 50-266/01-17; 50-301/01-17). Specifically, the licensee failed to identify potential common mode failures that existed involving power supplies to the recirculation line air-operated valve and other system components. In addition, the licensee's corrective actions for the potential common mode failure associated with a loss of instrument air did not preclude repetition. Specifically, the licensee's corrective actions, to upgrade the safety function of the air-operated recirculation valve, failed to ensure that successful operation of the recirculation line air-operated valve was dependent only on safety-related support systems. Following the corrective actions, successful operation of the valve was still dependent upon nonsafety-related power to an interposing relay. Additionally, the corrective actions failed to discover a single failure mechanism involving a system orifice modification. The issue was more than minor because the failure to implement appropriate corrective actions resulted in the
auxiliary feedwater system continuing to rely on nonsafety-related support systems and to be susceptible to a single event causing a total system failure. The failure of nonsafety-related support systems and single event failures are an expected condition during several design basis accidents and should not cause a safety system to fail. The failure of the licensee to implement adequate corrective actions is a violation of
10 CFR Part 50, Appendix B, Criterion XVI, Corrective Action.