05000029/LER-1976-006-01, /01T-0:on 760624,during Normal Operation,Routine Safety Injection Tank Makeup Was Performed Per Plant Procedure.Acceptance Criteria Not Met.Caused by Change 117, Suppl 3,requiring Limits on Boron Concentration

From kanterella
(Redirected from 05000029/LER-1976-006-01)
Jump to navigation Jump to search
/01T-0:on 760624,during Normal Operation,Routine Safety Injection Tank Makeup Was Performed Per Plant Procedure.Acceptance Criteria Not Met.Caused by Change 117, Suppl 3,requiring Limits on Boron Concentration
ML19345A393
Person / Time
Site: Yankee Rowe
Issue date: 07/08/1976
From: Janet Staub
YANKEE ATOMIC ELECTRIC CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19345A390 List:
References
LER-76-006-01T, LER-76-6-1T, NUDOCS 8011210283
Download: ML19345A393 (3)


LER-1976-006, /01T-0:on 760624,during Normal Operation,Routine Safety Injection Tank Makeup Was Performed Per Plant Procedure.Acceptance Criteria Not Met.Caused by Change 117, Suppl 3,requiring Limits on Boron Concentration
Event date:
Report date:
0291976006R01 - NRC Website

text

UCENSEE EVEFREPORT k

CONTROL ewCx:t I

i i

l l

I (PLE ; FRWT ALL ECUmC) WFIRMATION) 1 6

'7E5l' tcENsE uuM ER

'iO!'

'7!,"E 01 l.v l A l Y l Kl Rl 1l l0 l0 l-l 0l 0l 0l 0l0 l-l 0 l 0 l l 4l 1l1l 1l 1l lOl1l 7 89

,14 15 25 26 30 31 32 CATEGORY T

DOCKET NUMBER EVENT DATE REPORT OATE 01 CovT )

l l

[_TJ y 10 l 5 l 0 l-l 0 l 0 l 2 l 9l l0 l6 l2 l4 l 7l 6l l 0l 7l0 l 8 l 7 l 6 l 7 8 57 58 59 60 61 68 69 74 75 80 EVE'JT DESCR:PTION 0

l TSee Attached Sheet) 7 89

~

l 80

$l l

7 89 80 8l l

7 89 80 8I l

7 E9 80

$1 l

7 89

pay, go

{

COOE CCVPONENT COOE M JF R

VOLATON op iziz I l2j I zl zi zl zlz 121 l21 1 zi9 l9 I 91 lN l 7 89 13 11 12 17 43 44 47 48 CAUSE DESCR:PTION

s l (See Attached Sheet) l 7 69 80 cis i I

7 89 80 u: I i

s-

% POWER

. STATUS DSOOVERY 0:SCOVERY DESCRIPTON

[:j l0 l9 l8 l l

NA l

[_AJ l NA l

7 6 5

10 12 13 44 45 46 80 AC**/4TY CONTENT GE EASFO CF AELEASE AMOUNT OF ACTMTY tOCATON OF RELEASE Fia 1: 1 LzJ 1m i

I NA l

7 8 5

10 11 44 45 80 PER3ONNEL EXPOSURES P..VSER TYPE OESOR:PTION l

m IO!3101 1 Il I NA l

l 7 89 11 12 13 80 l

PEA 5DNNEL INJUR!ES l

e. _v E E R CESepppCN

  • l01,101 In l

7 89 11 12 80 OFFS.iE CONSEQUENCES 1

l U l

i L

7 89 80 l

LOSS OR OAMAGE TO FACILITY Tyst cEs nPTcN S ts W L NA l

7 89 10 go PUE.C.TY 1

l NA l

7 89 80 AOO.T.ONAL FACTORS I

.I 1

.8011210f{3 so is l

- l.

l 7 69

.80 l

NAME:

J. L. Staub 413-625-6140 PHONE:

CPC 841 667

b LER 76-06/0lT

(

EEVT DESCRIPTION Duri g normal operation a routine safety injection tank makeup was performed according to approved plant procedures.

The supervisor completing the procedure contacted higher supervision indicating he could not meet the acceptance criteria of the procedure and questioned the reason for the upper limit on Boron concentration.

The supervisor was informed that the acceptance criteria upper limit was based on the new accident analysis limit for boron precipitation.

Even through the safety injection tank boron concentration was' exactly at the safety analysis limit and greater than the conservative acceptance criteria of the procedure the concentration could not be decreased.

due to time limitations on the length of time the safety injection tank recirculation valve may be open during the month imposed by Technical Specification Change No. 126.

A subsequent review of procedures completed since start up of Core XII revealed that on ten (10) occasions the acceptance criteria had been exceeded during makeup without any corrective action and three (3) of these exceeded the safety analysis limit of 2400 ppm.

This incident is reported as Reportable Occurrence 50-29/76-06.

CAUSE DESCRIFFION Change 117, Supplement 3, Enclosure A required specific r.pper limits,

on boron concentration in the safety injection tank, safety injection accumulator and Main Coolant system to preclude boron precipitation in the unlikely event of a loss of coolant accident.

The potential consequences from this incident have been found to be minimal since a calculation of total ppm of boron based on volume weighed average conc.entration was less than that assumed in the accident analysis.

Previous cores had not required an upper limit on boron concentration.

Though the makeup procedure had been revised consistant with the safety analysis, the procedure had been performed with apparent disregard for the acceptance criteria.

Consequently, the boron concentration linits were exceeded in an attempt to leave a conservative margin to the low limit.

Chemistry calculations for makeup did not consider a high limit for similar reasons.

The personnel involved were reminded of their responsibilities to l

strictly adhere the plant procedure requirements.

I

1 l NRC ronu 195

(

U.S. NUCLEAR REGULA'ORY COM ION DOCKET NUMLE R

aasi, 50-29 NRC DISTRIBUTION FoR PART 50 DOCKET MATERI AL

'yr'CIDb REPORT I

TO:

FROM:

DATE oF DOCUMENT Yankee Atomig -Electric Company 7/8/76

)

Mr. J. P. O'Re'lly Rowe, Mass.

e'*

i DATE RECEIVED

'}

Mr. Herbert A. Autio 7/10/76 ILETTER ONoToRIZE D PROP INPUT FORM NUMBER oF COPIES RECEIVED DoAIGINAL

%NCLAsSIFIE D N 0'Y one signed copy DE3CRIPTION

's ENCLOSURE Ltr. trans the following:

Licensee Eve t Report (R0 S0-29/76-06/01T) on 6/24/76 concerning a routine safety injection tank makeup being performed and not meeting the acceptance criteria of the procedure.

3..p---

,--..,__..,,_ _f_;

w..

D O F' *"^

' - ~O (1-P)

(2-P)

PIR;T NAME:

IDTE:

IF PERSONNEL EXPOSURE IS INVOLVED SEND DIRECTLY TO KREGER/J.. COLLINS Yankee Rowe FOR ACTION /INFORMATION 7/13/76 RJL X ERA';CE CHIEF:

Schwencer W/3 CYS FOR ACTION [X LIC.. ASST.:

Sheppard

}

W/ / CYS I

ACES /,4CYS HOLDING /SE';T 'IO LA

'. ?

l INTERNAL DISTRIBUTION b(l3EG FII D W NBC PDR-V I & E (2) b( MIPC l XSCH30EDER/IPPOLITO

%)QUSION K

NOVAK/CEECK ix oRua:S XCASE

v mTLEa M EANAUER b[TEDESCO/"ACCARY b< EISENHUT rh X PAER I

,!vSHA0

  • t

%< VOLI23/FJNCH XKREGER/J. COLLINS i

I i

EXTERNAL DISTRIBUTION CONTROL NUMBE R L'X LPDR: Greenfield, Mass, b< TIC:

I V NSIC:

[ Cd