Semantic search
Jump to navigation
Jump to search
Issue date | From | Title | Project stage | |
---|---|---|---|---|
ULNRC-05844, Facility Operating License NPF-30 10 CFR50.55a Request: Proposed Alternative Regarding ASME OM Code Replacement Interval for Main Steam Isolation Value Actuator Rupture Disks | 30 March 2012 | Ameren Missouri Maglio S | Facility Operating License NPF-30 10 CFR50.55a Request: Proposed Alternative Regarding ASME OM Code Replacement Interval for Main Steam Isolation Value Actuator Rupture Disks | Request |
ML121010577 | 5 April 2012 | Thadani M Plant Licensing Branch IV | Request for Additional Information Re E-mail, Relief Request VR-01 from Requirements of ASME OM Code Mandatory Appendix I, One-time Extension Replacement of Main Steam Isolation Valve Actuator Rupture Disks | RAI |
ML121010569 | 9 April 2012 | Union Electric Co Elwood T | Attachment 5 | Other |
ML121010560 | 9 April 2012 | Union Electric Co Ameren Missouri Elwood T | Attachment 4 | Other |
ML121010557 | 9 April 2012 | Union Electric Co Elwood T | Attachment 3 | Other |
ML121010552 | 9 April 2012 | Union Electric Co Elwood T | Attachment 2 | Other |
ML121010538 | 9 April 2012 | Union Electric Co Elwood T | Attachment 1 | Other |
ML121010518 | 9 April 2012 | Union Electric Co Elwood T | Email Licensee Responses to Request for Additional Information Regarding Relief Request, Main Steam Isolation Valve Actuator Rupture Disks Replacement Interval | Response to RAI |
ML121010488 | 10 April 2012 | Balwant Singal Plant Licensing Branch IV | Request for Additional Information Email to the Licensee, Relief Request Main Steam Isolation Valve Actuator Rupture Disks Replacement Interval | RAI |
ML121150247 | 3 May 2012 | Kalyanam N Plant Licensing Branch IV | Memo to File, Verbal Authorization, Relief Request VR-01 from Requirements of ASME OM Code Mandatory Appendix I, One-time Extension Replacement of Main Steam Isolation Valve Actuator Rupture Disks | Other |
ML12220A232 | 9 August 2012 | Lyon C Plant Licensing Branch IV | Request for Additional Information, Verbal Authorization of Relief Request VR-01 from Requirements of ASME OM Code Mandatory Appendix I, One-time Extension Replacement of MSIV Actuator Rupture Disks | RAI |
ULNRC-05905, Response to NRC Request for Additional Information Regarding 10 CFR 50.55a Request: Proposed Alternative to ASME OM Code Replacement Interval for Main Steam Isolation Valve Actuator Rupture Disks | 10 September 2012 | Union Electric Co Ameren Missouri Maglio S | Response to NRC Request for Additional Information Regarding 10 CFR 50.55a Request: Proposed Alternative to ASME OM Code Replacement Interval for Main Steam Isolation Valve Actuator Rupture Disks | Response to RAI |
ML12258A045 | 18 September 2012 | Markley M Plant Licensing Branch IV | Relief Request VR-01 from Requirements of ASME OM Code, Mandatory Appendix I, One-time Extension for 5-Year Replacement Interval, from 4/11/12 to 6/2013, Main Steam Isolation Valve Actuator Rupture Disks | Other |