Semantic search

Jump to navigation Jump to search
 Issue dateFromTitleSiteProject stage
NOC-AE-15003315, Emergency License Amendment Request to Revise Technical Specification 5.3.2 to Allow Operation with 56 Full-Length Control Rod Assemblies for Cycle 203 December 2015South Texas
Gerry Powell
Emergency License Amendment Request to Revise Technical Specification 5.3.2 to Allow Operation with 56 Full-Length Control Rod Assemblies for Cycle 20South TexasRequest
NOC-AE-15003318, Response to Request for Additional Information and Supplement to Emergency License Amendment Request to Revise Technical Specification 5.3.2 to Allow Operation with 56 Full-Length Control Rod Assemblies for Cycle 209 December 2015South Texas
Gerry Powell
Response to Request for Additional Information and Supplement to Emergency License Amendment Request to Revise Technical Specification 5.3.2 to Allow Operation with 56 Full-Length Control Rod Assemblies for Cycle 20South TexasSupplement
NOC-AE-16003351, License Amendment Request to Revise Technical Specification 5.3.2 to Allow Operation with 56 Full-Length Control Rod Assemblies7 April 2016South Texas
Connolly J
License Amendment Request to Revise Technical Specification 5.3.2 to Allow Operation with 56 Full-Length Control Rod AssembliesSouth TexasRequest
ML16127A45212 May 2016Lisa Regner
Plant Licensing Branch IV
Supplemental Information Needed for Acceptance of Requested Licensing Action, Amendment Request to Revise Technical Specification 5.3.2 to Allow Operation with 56 Full-Length Control Rod AssembliesSouth TexasAcceptance Review
NOC-AE-16000338, Supplement to License Amendment Request to Revise Technical Specification 5.3.2 to Allow Operation with 56 Full-Length Control Rod Assemblies25 May 2016South Texas
Connolly J
Supplement to License Amendment Request to Revise Technical Specification 5.3.2 to Allow Operation with 56 Full-Length Control Rod AssembliesSouth TexasSupplement
ML16158A0626 June 2016Lisa Regner
Plant Licensing Branch IV
Acceptance of Requested Licensing Action Following Supplement, License Amendment Request to Revise Technical Specification 5.3.2 to Allow Operation with 56 Full-Length Control Rod AssembliesSouth TexasAcceptance Review
ML16188A3686 July 2016Westinghouse
Guthrie B
Schmitt D
Audit Presentation - Westinghouse Methodology for South Texas Unit 1 LAR: Operation with 56 Control RodsSouth TexasRequest
ML16214A29126 August 2016Lisa Regner
Plant Licensing Branch IV
Summary of June 28-30, 2016, Regulatory Audit at Westinghouse in Rockville, MD, License Amendment Request to Revise Technical Specification 5.3.2 to Allow Operation with 56 Full-Length Control Rod AssembliesSouth TexasOther
ML16246A09515 September 2016Lisa Regner
Plant Licensing Branch IV
Correction to 8/26/16 Request for Additional Information Enclosure, License Amendment Request to Revise Technical Specification 5.3.2 to Allow Operation with 56 Full-Length Control Rod AssembliesSouth TexasRAI
ML16319A01021 December 2016Lisa Regner
Plant Licensing Branch IV
Issuance of Amendment No. 211, Revise Technical Specification 5.3.2 to Allow Operation with 56 Full-Length Control Rod AssembliesSouth TexasApproval