ND-23-0439, ITAAC Closure Notification on Completion of ITAAC 2.2.05.07a.i (Index Number 265) | 18 July 2023 | ITAAC Closure Notification on Completion of ITAAC 2.2.05.07a.i (Index Number 265) | |
05000425/LER-2017-002 | 17 November 2017 | Valid Undervottage Condition results in Automatic Actuation of a Safety System LER 17-002-00 for Vogtle, Unit 2, Regarding Valid Undervoltage Condition Results in Automatic Actuation of a Safety System | |
05000424/LER-2017-002 | 29 June 2017 | Vice President Vogtle Units 1-2 7821 River RD Waynesboro GA, 30830 706-848-0004 tel 706-848-3321 fax June 29, 2017 Docket No: 50-424 NL-17-1104 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Vogtle Electric Generating Plant — Unit 1 Licensee Event Report 2017-002-01 Wiring Error results in Automatic Actuation of a Safety System Ladies and Gentlemen: In accordance with the requirements of 10 CFR 50.73(a)(2)(iv)(A), Southern Nuclear Operating Company is submitting the enclosed Licensee Event Report, 2017-002-01 for Vogtle Electric Generating Plant Unit 1. This letter contains no NRC commitments. If you have any questions, please contact Dom Sutton at (706) 848-1428. Respectfully sub Darin J. M rs Vice President — Plant ogtle Units 1&2 - SNC DJM/KCW Enclosure: Unit 1 Licensee Event Report 2017-002-01 Cc: Regional Administrator NRR Project Manager — Vogtle 1 & 2 Senior Resident Inspector — Vogtle 1 & 2 RType: CVC7000 Vogtle Electric Generating Plant — Unit 1 Licensee Event Report 2017-002-01 Wiring Labeling Error results in Automatic Actuation of a Safety System Enclosure Unit 1 Licensee Event Report 2017-002-01 NRC FORM 366 U.S. NUCLEAR REGULATORY COMMISSION (04-2017) LICENSEE EVENT REPORT (LER) ILWa t l,viricir (See Page 2 for required number of digits/charactersfor each block) ••••••• (See NUREG-1022, R.3 for instruction and guidance for completing this form http://www.nrc.qovireadincl-rmidoc-collections/nuregs/staff/sr1022/r3i) APPROVED BY OMB: NO. 3150-0104 EXPIRES: 0313112020 Estimated burden per response to comply with this mandatory collection request: 80 hours Reported lessons learned are incorporated into the licensing process and fed back to industry Send comments regarding burden estimate to the Information Services Branch (T-2 F43), US Nuclear Regulatory Commission, Washington, DC 20555-0001, or by e-mail to Infocollects Resource@nrc gov, and to the Desk Officer, Office of Information •and Regulatory Affairs, NEOB-10202, (3150-0104), Office of Management and Budget, Washington. DC 20503. If a means used to impose an information collection does not display a currently valid OMB control number, the NRC may not conduct or sponsor, and a person is not required to respond to, the information collection. 1. FACILITY NAME Vogtle Electric Generating Plant . DOCKET NUMBER 13. PAGE 17.:15000424 1 1 OF 2 4. TITLE Mirina Error results in_AulomaticActuation_of a Safety System_ LER 17-002-01 for Vogtle, Unit 1, Wiring Error Results in Automatic Actuation of a Safety System | |
05000425/LER-2017-001 | 29 June 2017 | 1 OF 3 LER 17-001-01 for Vogtle, Unit 2, Regarding Power Supply Failure Results in Operation in a Condition Prohibited by Technical Specifications Supplement | |
NL-10-0577, LER 10-S01-00 for Vogtle, Units 1 & 2 Regarding Supplemental Worker'S Unescorted Access Not Revoked in a Timely Manner | 30 March 2010 | LER 10-S01-00 for Vogtle, Units 1 & 2 Regarding Supplemental Worker'S Unescorted Access Not Revoked in a Timely Manner |