Pages that link to "05000328/LER-1982-002, Forwards LER 82-002/03L-0"
Jump to navigation
Jump to search
The following pages link to 05000328/LER-1982-002, Forwards LER 82-002/03L-0:
Displayed 25 items.
- ML20040G833 (redirect page) (← links)
- 05000328/LER-1982-002-03, /03L-0:on 820112,turbine Driven Auxiliary Feedwater Pump Declared Inoperable Due to Failure to Start on Safety Actuation.Caused by Failure to Reset Electronic Overspeed Trip Latch Function.Valve Trip Latch Reset (← links)
- 05000328/LER-1982-002, Forwards LER 82-002/03L-0 (← links)
- 05000328/LER-1982-002, Forwards Updated LER 82-002/03X-1 (redirect page) (← links)
- ML20055A158 (← links)
- 05000328/LER-1982-049-03, /03L-0:on 820330,w/unit in Mode 1 at 30% Reactor Power,One Upper Containment Airlock Door Found Jammed Closed.Caused by Failure of CAM Roller Bearing in Operating Mechanism.Bearing Replaced & Door Satisfactorily Tested (← links)
- 05000327/LER-1982-046-03, /03L-0:on 820205,surveillance Instruction 166.6 Not Performed on Steam Generator Blowdown Isolation Valve, Found During Review of Maint Requests on 820326.Caused by Misplaced Maint Request (← links)
- 05000327/LER-1982-051-03, /03L-0:on 820423,containment Ventilation Isolation Sys Declared Inoperable Due to Loss of Automatic Initiation Capability.Caused by Design Error Which Prevents Automatic Reactuation After Isolation Signal Reset (← links)
- 05000327/LER-1982-053-03, /03L-0:on 820415,vital Battery Bank II Declared Inoperable When Cell 4 Connection Resistance Found Greater than 150 micro-ohms.Caused by Loose Bolt Connection.Bolt Torqued & Resistance Checked (← links)
- 05000327/LER-1982-053, Forwards LER 82-053/03L-0 (← links)
- 05000328/LER-1982-032, Forwards LER 82-032/03L-0 (← links)
- 05000327/LER-1982-050-03, /03L-0:on 820413,diesel Generator 1A.A Declared Inoperable When Power Fuses Blew in Control Circuitry.Caused by Broken Lead on Annunciator Horn Shorting to Case.Horn Replaced (← links)
- 05000327/LER-1982-050, Forwards LER 82-050/03L-0 (← links)
- 05000327/LER-1982-048-03, /03L-0:on 820408,at 100% Power,Automatic Control Valve 1-PCV-3-132 in Auxiliary Feedwater Sys Flowpath Failed to Open on Demand.Caused by Faulty Soldered Amphenol Connector to Electrohydraulic Actuator.Connector Repaired (← links)
- 05000328/LER-1982-026-03, /03L-0:on 820221,containment Sump Level Transmitter 2-LT-65-176 Inoperable Due to High Readings. Caused by Leaking Sensor Bellows.Sensor Bellows Replaced & Transmitter Recalibr (← links)
- 05000328/LER-1982-026, Forwards LER 82-026/03L-0 (← links)
- 05000327/LER-1982-025-03, /03L-0:on 820212,pressurizer Level Channel 1-LT-68-335 Declared Inoperable.Caused by Transmitter Out of Calibr Due to Instrument Drift.Barton Model 764 Transmitter Recalibr (← links)
- 05000327/LER-1982-025, Forwards LER 82-025/03L-0 (← links)
- 05000327/LER-1982-027-01, /01T-0:on 820307,while Preparing to Perform SI-566,ERCW Flow Verification Test,Containment Spray Heat Exchanger 1A Found W/Low Essential Raw Cooling Water Flow. Caused by Fresh Water Clams in Piping.Clams Removed (← links)
- 05000327/LER-1982-027, Forwards LER 82-027/01T-0 (← links)
- 05000327/LER-1982-024-03, /03L-0:on 820218,turbine Bldg Sump & Condensate Demineralizer Radioactive Effluent Line Monitors Declared Inoperable.Caused by Crud & Debris Buildup on Flow Switch. Switches Cleaned (← links)
- 05000327/LER-1982-024, Forwards LER 82-024/03L-0 (← links)
- 05000327/LER-1982-028, Forwards LER 82-028/03L-0 (← links)
- 05000327/LER-1982-029-03, /03L-0:on 820215,w/unit in Mode 3,glycol Containment Isolation Valve 1-FCV-61-194 Would Not Reopen When Stroked from Full Open Position.Caused by Conductor G1B1 Not Being Terminated.Conductor Reterminated (← links)
- 05000328/LER-1982-022, Forwards LER 82-022/03L-0 (← links)
- 05000328/LER-1982-021-01, /01T-0:on 820217,during Startup,Shutdown Rods in Shutdown Bank a Exceeded Plus/Minus 12 Steps of Actual Position on Indicators.Caused by Misinterpretation of Limiting Condition for Operation 3.1.3.3.Rods Recalibr (← links)
- 05000328/LER-1982-021, Forwards LER 82-021/01T-0 (← links)
- 05000328/LER-1982-016-03, /03L-0:on 820127,steam Generator Pressure Channels for Loops 3 & 4 to Remote Shutdown Instrumentation Declared Inoperable Due to Failure to Meet Channel Check Requirements.Caused by Open Circuit on Loop 2-PI-1-19C (← links)
- 05000328/LER-1982-016, Forwards LER 82-016/03L-0 (← links)
- 05000327/LER-1982-017, Forwards LER 82-017/03L-0 (← links)
- 05000327/LER-1982-020-03, /03L-0:on 820203,emergency Gas Treatment Sys Room Cooler Declared Inoperable Due to Fuses Blowing in Coolers Control Circuitry.Caused by Shorted Solenoid Coil of 2-FSV-67-338.Coil Replaced (← links)
- 05000327/LER-1982-020, Forwards LER 82-020/03L-0 (← links)
- 05000327/LER-1982-070, Forwards LER 82-070/01T-0 (← links)
- 05000327/LER-1982-018, Forwards LER 82-018/03L-0 (← links)
- 05000328/LER-1982-013-03, /03L-0:on 820118,steam Generator 3 Feedwater Flow Transmitter Loop 2-FT-3-90A Declared Inoperable.Caused by Frozen Sense Lines.Lines Thawed & Insulation Added.Design Change Request Initiated (← links)
- 05000328/LER-1982-009-03, /03L-0:on 820111,in Mode 1 at 8% Rtp,Steam Generator Blowdown Containment Isolation valve,2-FCV-1-7, Operator Diaphragm Ruptured Rendering Valve Inoperable. Caused by Normal Wear.Diaphragm Replaced (← links)
- 05000328/LER-1982-004-03, /03L-0:on 820115,vital Battery Bank II Cell Temp Found to Be Less than 60 F,Rendering Sys Inoperable.Caused by Two Exhaust Fan Dampers Open Simultaneously.One Damper Closed & Room Heat Increased (← links)
- 05000327/LER-1982-006-03, /03L-0:on 820115,turbine Driven Auxiliary Feedwater Pump Declared Inoperable Due to Failure to Meet Surveillance Requirements.Caused by Malfunction in Controller 1-FIC-46-57.Controller Replaced (← links)
- 05000327/LER-1982-008-03, /03L-0:on 820114,auxiliary Feedwater Level Control Valve 1-1CV-3-156 Would Not Operate While Attempting to Control Level on Steam Generator.Caused by Failure of Valve Position Controller.Controller Replaced (← links)
- 05000328/LER-1982-001-03, /03L-0:on 820103,ice Condenser Intermediate Deck Door 9.B Discovered Frozen Shut.Caused by Humidity Entering Through Top Deck Blanket Vents,Condensed on I-beams & Dripping Onto Intermediate Deck Door.Ice Removed (← links)
- 05000328/LER-1982-002 (redirect page) (← links)
- 05000328/LER-1982-013, Forwards LER 82-013/03L-0 (← links)
- 05000328/LER-1982-004-03, /03L-0:on 820115,vital Battery Bank II Cell Temp Found to Be Less than 60 F,Rendering Sys Inoperable.Caused by Two Exhaust Fan Dampers Open Simultaneously.One Damper Closed & Room Heat Increased (← links)
- 05000328/LER-1982-004, Forwards LER 82-004/03L-0 (← links)
- 05000328/LER-1982-005-03, /03L-0:on 820113,remote Shutdown Instrument Channel or Pressurizer Relief Tank Level Declared Inoperable Due to Failure to Meet Surveillance Requirements Caused by Faulty Resistor in Transmitter Circuit Card (← links)
- 05000328/LER-1982-002-03, /03L-0:on 820112,turbine Driven Auxiliary Feedwater Pump Declared Inoperable Due to Failure to Start on Safety Actuation.Caused by Failure to Reset Electronic Overspeed Trip Latch Function.Valve Trip Latch Reset (← links)
- 05000328/LER-1982-010-03, /03L-0:on 820109,loop 3 Steam Generator Pressure Transmitter 2-PT-1-20A Declared Inoperable.Caused by Frozen Sense Line.Lines Thawed.Similar Incidents Occurred on 820110 & 11 (← links)
- 05000328/LER-1982-010, Forwards LER 82-010/03L-0 (← links)
- 05000327/LER-1982-007-03, /03L-0:on 820108,in Mode 1 at 100% Power,Rod Position Indicator P-4 (Shutdown Bank a) Indicated Greater than 12 Steps Below Step Counter.Defective Indicator Recalibr & Returned to Svc.Connector Pins Cleaned (← links)
- 05000327/LER-1982-145-03, /03L-0:on 821218,while in Mode 5,latch Mechanisms for Containment Ventilation Isolation Slave Relays Failed to Latch When Relay Energized.Cause Unknown.Equipment Removed & Replaced.Evaluation Continuing (← links)
- 05000327/LER-1982-140-03, /03L-0:on 821207,combined Leakage Rate & Combined Bypass Leakage Exceeded Acceptable Limits.Caused by Faulty Upper & Lower Personnel Airlocks & Leakage Paths X-62 & X-111.Items Repaired (← links)
- 05000327/LER-1982-140, Forwards LER 82-140/03L-0 (← links)
- 05000327/LER-1982-130, Forwards LER 82-130/03L-0 (← links)
- 05000328/LER-1982-127-03, /03L-0:on 821020,cooling Jacket Circulating Water Pump on Diesel Generator 2B-B Found Inoperable.Caused by Ball Bearing Failure.Pump Replaced (← links)
- 05000328/LER-1982-127, Forwards LER 82-127/03L-0 (← links)
- 05000327/LER-1982-123, Forwards LER 82-123/01T-0 (← links)
- 05000328/LER-1982-120-03, /03L-0:on 820930,at 96% Rtp,Lower Containment Personnel Airlock Outer Door Discovered Broken.Caused by Failure of cam-roller Bearing in Door Gear Box Due to Normal Wear & Poor Preventive Maint.Bearing Replaced (← links)
- 05000327/LER-1982-114-03, /03L-0:on 820929,while in Mode 5,auxiliary Bldg Ventilation Radiation Monitor Declared Inoperable Due to Loss of Sample Flow.Caused by Broken Drive Belt on Sample Flow Vacuum Pump Due to Normal Wear.Belt Replaced (← links)
- 05000327/LER-1982-114, Forwards LER 82-114/03L-0 (← links)
- 05000328/LER-1982-119-03, /03L-0:on 820927,during Mode 1 Operation & Performance of SI-166-1,containment Isolation Valve 2-FCV-30-17 Failed to Open.Caused by Open Coil in Valve Operator.Coil Replaced.Valve Returned to Svc (← links)
- 05000328/LER-1982-109-03, /03L-0:on 820826,during Mode 1,hot Leg Sample Valve 2-FCV-43-22 Would Not Open.Caused by Open Limit Switch Being Out of Adjustment.Switch Adjusted,Valve Tested & Returned to Svc (← links)
- 05000328/LER-1982-109, Forwards LER 82-109/03L-0 (← links)
- 05000328/LER-1982-105-03, /03L-0:on 820810,while in Mode 1,one Refueling Water Storage Tank Failed Low & Declared Inoperable.Caused by Faulty Amplifier Card.Transmitter Replaced & Loop Returned to Svc (← links)