Pages that link to "05000373/LER-1982-149, Forwards LER 82-149/03L-0"
Jump to navigation
Jump to search
The following pages link to 05000373/LER-1982-149, Forwards LER 82-149/03L-0:
Displayed 14 items.
- ML20079H743 (redirect page) (← links)
- 05000373/LER-1982-149 (redirect page) (← links)
- ML20072F663 (redirect page) (← links)
- 05000373/LER-1982-149, Forwards Updated LER 82-149/03X-1 (redirect page) (← links)
- 05000373/LER-1982-153, Forwards Updated LER 82-153/03X-1 (← links)
- 05000373/LER-1982-158-03, /03L-0:on 821122,drain Valve 1B21-F016 Would Not Seal in Close Direction.Caused by Dirty Contacts in Closing Torque Switch.Torque Switch Contacts Cleaned & Settings Verified (← links)
- 05000373/LER-1982-149-03, /03L-0:on 821112,lake Blowdown Flow Recorder Discovered Giving Incorrect Readings.Caused by Algae Buildup on Instrument Probe.Probe Cleaned & Weekly Functional Test Will Be Performed (← links)
- 05000373/LER-1982-093-03, /03L-0:on 820821,during Reactor Core Isolation Cooling (RCIC) Insp,Rcic Turbine Found Leaking Oil from Sight Glass.Caused by Worn Sight Glass Gaskets.Gaskets Replaced (← links)
- 05000373/LER-1982-178-03, /03L-0:on 821230 & 31,low Pressure Alarms Received for Automatic Depressurization Sys Valves S,C & U.Caused by Blowback of Drywell Pneumatic Air Dryer 1B to Drywell & Leak in Instrument Nitrogen Supply Check Valve (← links)
- 05000373/LER-1982-180-03, /03L-0:on 821230,review of Tech Spec Table 3.7.9-2 Revealed Several Administrative & Clerical Errors. Caused by Issuing Tech Specs Prior to Incorporation of Final Linewalk Info.Table Will Be Revised (← links)
- 05000373/LER-1982-177-03, /03L-0:on 821230,RHR Full Flow Test Valve a 1E12-F024A Did Not Close Fully When Sys Was Being Shut Down. Caused by Unadjusted Light Switch Cam on Throttlable Valve. Closing Torque Switch Replaced (← links)
- 05000373/LER-1982-147-03, /03L-0:on 821111,offgas B Train Hydrogen Analyzer Began Operating Erratically.Caused by Moisture Entering Sensitive Hydrogen Sensors in Units.Hydrogen Sensors Removed,Dried Out & Replaced (← links)
- 05000373/LER-1982-145-03, /03L-0:on 821107,chlorine & Ammonia Detector B Alarmed & Would Not Reset.Caused by Dirty Lens.Lens Cleaned & Detector Returned to Svc (← links)
- 05000373/LER-1982-143-03, /03L-0:on 821102,offgas Pretreatment Monitor Inoperable.Caused by Loss of Flow Due to Water in Sample Line.Sample Line Drained.Temporary Heat Trace Installed to Keep Gas at Higher Temp.Mod M-1-1-82-227 Written (← links)
- 05000373/LER-1982-140-03, /03L-0:on 821030,offgas Pretreatment Monitor Became Inoperative.Caused by Loss of Flow Due to Water in Sample Line.Sample Line Drained.Purge Valve Installed to Allow Proper Flow (← links)
- 05000373/LER-1982-106-03, /03L-0:on 820920,during Performance of LOS-PC-Q1, Valve 1B33-F019 Did Not Close.Caused by Foreign Matl Blocking Valve Open.Outboard Isolation Valve 1B33-F020 Closed.Blockage Removed Prior to Work Initiation (← links)