Pages that link to "05000373/LER-1982-113, Forwards LER 82-113/03L-0"
Jump to navigation
Jump to search
The following pages link to 05000373/LER-1982-113, Forwards LER 82-113/03L-0:
Displayed 21 items.
- ML20069H761 (redirect page) (← links)
- 05000373/LER-1982-113 (redirect page) (← links)
- 05000373/LER-1982-134, Forwards LER 82-134/03L-0 (← links)
- 05000373/LER-1982-176-03, /03L-0:on 821228,while RHR B Sys Was in Suppression Pool Cooling Mode,Excessive Vibration Noted on RHR 1B Pump Shaft.Caused by Excessive Wear on Bearings. Bearings Replaced (← links)
- 05000373/LER-1982-180-03, /03L-0:on 821230,review of Tech Spec Table 3.7.9-2 Revealed Several Administrative & Clerical Errors. Caused by Issuing Tech Specs Prior to Incorporation of Final Linewalk Info.Table Will Be Revised (← links)
- 05000373/LER-1982-155-03, /03L-0:on 821118,secondary Containment Violated in Reactor Bldg at 761-ft Elevation Due to Doors 418 & 285 Opening Simultaneously.Caused by Malfunctioning Latch Bolt Due to Electric Strike out-of-adjustment at Door 285 (← links)
- 05000373/LER-1982-150-03, /03L-0:on 821111,RCIC Flow Controller Failed to Control RCIC Sys Flow During Performance of STP-14.Caused by Loose Leads at Square Root Converter 1E51-K601.Leads Tightened.Rcic Sys Successfully Run (← links)
- 05000373/LER-1982-147-03, /03L-0:on 821111,offgas B Train Hydrogen Analyzer Began Operating Erratically.Caused by Moisture Entering Sensitive Hydrogen Sensors in Units.Hydrogen Sensors Removed,Dried Out & Replaced (← links)
- 05000373/LER-1982-145-03, /03L-0:on 821107,chlorine & Ammonia Detector B Alarmed & Would Not Reset.Caused by Dirty Lens.Lens Cleaned & Detector Returned to Svc (← links)
- 05000373/LER-1982-144-03, /03L-0:on 821107,Div 1 Battery Charger Declared Inoperable Due to Defective Dc Output Breaker.Battery Also Out Due to Prolonged Discharge W/Specific Gravities Exceeding Min Value.Caused by Poor Connections (← links)
- 05000373/LER-1982-143-03, /03L-0:on 821102,offgas Pretreatment Monitor Inoperable.Caused by Loss of Flow Due to Water in Sample Line.Sample Line Drained.Temporary Heat Trace Installed to Keep Gas at Higher Temp.Mod M-1-1-82-227 Written (← links)
- 05000373/LER-1982-140-03, /03L-0:on 821030,offgas Pretreatment Monitor Became Inoperative.Caused by Loss of Flow Due to Water in Sample Line.Sample Line Drained.Purge Valve Installed to Allow Proper Flow (← links)
- 05000373/LER-1982-106-03, /03L-0:on 820920,during Performance of LOS-PC-Q1, Valve 1B33-F019 Did Not Close.Caused by Foreign Matl Blocking Valve Open.Outboard Isolation Valve 1B33-F020 Closed.Blockage Removed Prior to Work Initiation (← links)
- 05000373/LER-1982-108-03, /03L-0:on 820920,LIS-NB-187,ADS Accumulator Backup N2 Channel Functional & Calibr Discovered Not Performed as Specified by Tech Spec.Caused by Surveillance Procedure Not Entered Into Program.Procedure Revised (← links)
- 05000373/LER-1982-113-03, /03L-0:on 820816,D Fuel Pool Vent Exhaust Radiation Monitor Found Inoperable.Caused by Bad Sensor Convertor Mfg by Ge,Model 194X9276011.Convertor Replaced (← links)
- 05000373/LER-1982-104-03, /03L-0:on 820916,offgas Sys Hydrogen Analyzers Found Reading Erroneously.Caused by Stock Solenoid Valve on a Train Analyzer & Defective Sensor on B Train Analyzer. Solenoid Cleaned & Sensor Replaced (← links)
- 05000373/LER-1982-137-03, /03L-0:on 821026,both Reactor Recirculation Pumps Received Downshift Signal.Pump 1A Downshifted,But Pump 1B Did Not Pick Up in Slow Speed & Drifted to Stop,Resulting in Tripping of Pump 1A.Caused by Feedwater Low Flow Transi (← links)
- 05000373/LER-1982-134-03, /03L-0:on 821021,observed That Reactor Bldg Ventilation Sys Would Not Maintain Required Pressure.Caused by Closed Damper Which Became Stuck During Vr Sys Startup. Standby Gas Treatment Sys Started & Work Request Issued (← links)
- 05000373/LER-1982-128-03, /03L-0:on 821018,standby Gas Treatment Sys Electric Heating Coil 2VG01A Failed to Energize During Performance of LOS-VG-M1,standby Gas Treatment Sys Operability Test.Caused by out-of-calibr Flow Transmitter (← links)
- 05000373/LER-1982-120-03, /03L-0:on 821010,offgas Hydrogen Analyzer 1N62-N009A Tripped Off on Low Flow Condition.Caused by Sample Line Inlet Filter Clogged W/Rust Particulates.Work Request Written (← links)
- 05000373/LER-1982-044-03, /03L-0:on 820608,instrument Rack Root Stop Valve IE22-F329 Found Closed & Seal Wire Missing During Suppression Chamber Calibr & Functional Test.Cause Not Determined.Onsite Review Performed During Wk of 820621 (← links)