Pages that link to "05000338/LER-1978-061, Forwards LER 78-061/99X-1 & 78-089/03L-0"
Jump to navigation
Jump to search
The following pages link to 05000338/LER-1978-061, Forwards LER 78-061/99X-1 & 78-089/03L-0:
Displaying 50 items.
- 05000338/LER-1978-111, Forwards LER 78-111/01T (← links)
- 05000338/LER-1978-107, Forwards LER 78-107/03L-0,LER 78-108/03L-0 & LER 78-109/03L-0 (← links)
- 05000338/LER-1978-091, Forwards LER 78-091/03L-0,LER 78-092/03L-0,LER 78-094/03L-0, LER 78-095/03L-0,LER 78-096/03L-0,LER 78-097/03L-0, LER 78-099/03L-0 & LER 78-103/03L-0 (← links)
- 05000338/LER-1978-090, Forwards LER 78-090/03L-0 (← links)
- 05000338/LER-1978-098, Forwards LER 78-098/01T-0 (← links)
- ML20064B968 (redirect page) (← links)
- 05000338/LER-1978-106-03, /03L-0:on 781010,power-range Instrumentation Channel N-41 Taken Out of Svc to Facilitate Replacement of Faulty Gain Pot.Caused by Dirt in Potentiometer,Resulting in Erratic Gain (← links)
- 05000338/LER-1978-105-03, /03L-0:on 781010,axial Flux Difference Deviated Greater than 5%.Caused by Rapid Load Reduction Necessitated by Problems W/Condenser Circulating Water Valve (← links)
- 05000338/LER-1978-104-03, /03L-0:on 781009,during Mode 1,leak Detected in Steam Valve 1-MS-120 Valve Leads to Steam Generator Auxiliary Feedwater Pump 1-FW-P-2.Caused by Isolation of Steamline,Causing Pump Inoperability (← links)
- 05000338/LER-1978-093-03, /03L-0:on 781017,multiplier Divider Card Output Drifted So That steam-feedwater Flow Mismatch Would Not Trip Until Actual Value of 1,932,000 Lbs Per Hour Occurred.Caused by Electronic Drift in Card.Card Recalibr (← links)
- 05000338/LER-1978-085-03, /03L-0 on 780830:Testing of Quench Spray Pump 1-QS-P-1B Showed Pressure Drop of Over 10psi on the Suction Line During Oper,Caused by Wooden Dam in Piping. (Encl to 7810030071) (← links)
- 05000338/LER-1978-138-03, /03L-0 on 781228:during Operation Indication from Pressure Transmitter 1494,1 C Steam Generator Failed High,Caused by Faulty Power Supply.Associated Pressure Channel Taken Out of Svc & Faulty Card Replaced (← links)
- 05000338/LER-1978-127-03, /03L-0 on 781204:during Pwr Reduction,Axial Flux Difference Deviated Greater than 5%;during Return to Full Pwr Afd Deviated Greater than -5%.Caused by Load Reduction Caused by Unit Being on Load Following (← links)
- 05000338/LER-1978-127, Forwards LER 78-127/03L-0 (← links)
- 05000338/LER-1978-125-01, /01T-0 on 781130:noted That Emergency Diesel Generator Battery Racks Were Improperly Installed.Caused by Failure to Perform Requested Mods (← links)
- 05000338/LER-1978-125, Forwards LER 78-125/01T-0 (← links)
- 05000338/LER-1978-121-03, /03L-0 on 781111:during Pwr Reduction,Axial Flux Difference Deviated Greater than Tech Spec Limits.Deviation Caused by Rapid Load Reduction Caused by Failure of Turbine Governor Valve 4 to Open During Test (← links)
- 05000338/LER-1978-121, Forwards LER 78-121/03L-0 (← links)
- 05000338/LER-1978-123-03, /03L-0 on 781115:Detectors a & B of Incore Movable Detector Sys Stuck in Inserted Position Due to Fouled Incore Movable Detector Guide Thimbles (← links)
- 05000338/LER-1978-123, Forwards LER 78-123/03L-0 (← links)
- 05000338/LER-1978-108-03, /03X-1 on 781012:during Mode 1 Opers,At 100% Pwr, Feedwater Flow Transmitter FT-1496 on Feedwater Loop C Failed Low.Caused by Blown Fuse.Fuse Subsequently Replaced (← links)
- 05000338/LER-1978-108, Forwards LER 78-108/03X-1 (← links)
- 05000338/LER-1978-063-03, /03X-1 on 780728:particulate Filter & Charcoal Filter Were Clogged.Caused by Driving Mechanism of RM-RMS-159 Filter Being Jammed (← links)
- 05000338/LER-1978-063, Forwards LER 78-063/03X-1 (← links)
- 05000338/LER-1978-119-03, /03L-0 on 781110:during Critical Steady State Oper Alarms Showed High Steam Line Differential Pressure on Line B.Proper Bistables Tripped,Placing Plant in Safe Condition. Caused by Faulty Instru Loop Pwr Supply Card in Circu (← links)
- 05000338/LER-1978-119, Forwards LER 78-119/03L-0 (← links)
- 05000338/LER-1978-124-01, /01T-0 on 781116:Svc Water & Component Cooling Piping & Pipe Supports Not Analyzed for Thermal & Seismic Stresses.Design Personnel Utilized Wrong Svc Water Temps for Stress Analysis.Present Analysis Shows Adequate Support (← links)
- 05000338/LER-1978-124, Forwards LER 78-124/01T-0 (← links)
- 05000338/LER-1978-117-03, /03L-0 on 781101:main Steam Trip Valve 1-TV-MS-111A Was Detected Leaking Due to a Deteriorated Internal Gasket.Valve Was Isolated & Gasket Replaced (← links)
- 05000338/LER-1978-116-03, /03L-0 on 781102:during Pwr Escalation,Upper Flux Deviation Alarm Was Received & Traced to a High Quadrant Pwr Tilt Ratio.Believed Cause Was Nonlinear Detector Resonse at Lower Pwr (← links)
- 05000338/LER-1978-115-03, /03L-0 on 781107:during 1-pt-134 Periodic Test, MOV-QS102A Would Not Return to Normal Closed Position Because of Dirty Contacts on Valves Torgue Switch.Contacts Were Cleaned (← links)
- 05000338/LER-1978-114-03, /03L-0 on 781101:axial Flux Difference Deviated Greater than -5% from Target for One Minute.Caused by Pwr Reduction Necessitated by Problem with Cooling Fans on Main Station Transformer C (← links)
- 05000338/LER-1978-114, Forwards LER 78-114/03L-0,78-115/03L-0,78-116/03L-0 & 78-117/03L-0 (← links)
- 05000338/LER-1978-113-03, /03l-0 on 780927:after maint,TV-BD100A,B,D & F Were Tested But Not Timed Prior to Return to Svc,Due to Personnel Error.Personnel Have Reviewed the Requirements (← links)
- 05000338/LER-1978-110-03, /03l-0 on 781024:following a Reactor Trip,The Containment Bulk Avg Temp Exceeded 105 Degrees F Tech Spec Limit Due to Steam Loss to Chilled Water Sys Vacuum Refrigeration Unit (← links)
- 05000338/LER-1978-100-01, /01X-0 on 781108:a Field Mod Was Made to Vessel Lower Head Insulation & the Mod Was Not Seismically Analyzed IAW FSAR Due to Personnel Error.Subsequently Analyzed by Stone & Webster & by Westinghouse (← links)
- 05000338/LER-1978-100, Forwards LER 78-100/01X-0, 78-110/03L-0 & 78-113/03L-0 (← links)
- 05000338/LER-1978-120-01, /01T-0 on 781121:inspec of Station Battery Racks Revealed That Racks Had Been Improperly Assembled & Installed During Constr.Deficiencies Will Be Corrected (← links)
- 05000338/LER-1978-122-01, /01T-0 on 781113:during Steady State Oper,It Was Discovered That Only One Seal or Barrier Exists for Spare Pipe Penetrations in Conflict W/Fsar Due to Oversight of Design Personnel.Engineering Is Analyzing It for Solution (← links)
- 05000338/LER-1978-120, Forwards LER 78-120/01T-0 & LER 78-122/01T-0 (← links)
- 05000338/LER-1978-118, Forwards LER 78-118/99T-0 (← links)
- 05000338/LER-1978-112-03, /03L-0 on 781025:During Routine Startup Oper,Axial Flux Difference Deviated Greater than 5% from target.48 Penalty Min Accumulated.Caused by Xenon Transient Occurrence.Corrective Action:Boration by Reactor Operator (← links)
- 05000338/LER-1978-112, Forwards LER 78-112/03L-0 (← links)
- 05000338/LER-1978-089-03, /03X-1 on 780915:during Periodic Test,A Bistable (FC-1485 in Protec Channel Iv)Associated W/Hi Steamline Flow S.I.Actuation Failed to Trip,Due to Defective Bistable Card (← links)
- 05000338/LER-1978-026-99, /99X-1 on 780413:with All Rods Out at Beginning of Core Life,Hot Zero Pwr Moderator Temp Coefficient Revealed It Was More Positive than 0 Delta K/K/F in Tech Spec,Due to Positive Mtc for the all-rods-out Configuration (← links)
- 05000338/LER-1978-026, Forwards LER 78-026/99X-1 & 78-089/03X-1 (← links)
- 05000338/LER-1978-111-01, /01T-0:on 781025,nonseismically Qualified Instantaneous Contacts & Agastat Timers Used in Control Circuits for MOV-QS-102A & MOV-QS-102B.Control Circuit Will Be Modified by Design Change (← links)
- 05000338/LER-1978-109-03, /03L-0:on 781011,during Functional Test on Containment Hydrogen Recombiner 2-HC-HC-1,heater Gas Temp Failed to Reach Greater than 700 F.Caused by Operator Selecting Improper Control Settings (← links)
- 05000338/LER-1978-107-03, /03L-0:on 781005,during Full Power Operation, Containment Atmosphere & Gas Monitoring Sys Inoperable.On 781005,breaker to Containment Atmosphere Particulate & Gas Monitoring Pump Opened,Cutting Power to Sys (← links)
- 05000338/LER-1978-102-03, /03L-0:on 781002,during Mode 3 Operation,Channel 3 of Steam Generator Level Indicator LI-1496 Tripped.Caused by Leak on Manifold Gasket Below Level Transmitter Resulting in Low Reading (← links)