- 05000333/LER-1983-007, Forwards LER 83-007/03L-0 (← links)
- 05000333/LER-1983-008, Forwards LER 83-008/01T-0 (← links)
- 05000333/LER-1983-006, Forwards LER 83-006/03L-0 (← links)
- 05000333/LER-1983-012, Forwards LER 83-012/04T-0 (← links)
- 05000333/LER-1983-002, Forwards LER 83-002/03L-0 (← links)
- 05000333/LER-1983-003, Forwards LER 83-003/03L-0 (← links)
- 05000333/LER-1983-042, Submits Rev to 831013 Cover Ltr & Forwards LER 83-042/03L-1. Original Ltr Erroneously Listed Rept as 83-048 & LER Had Error in Reporting Date (← links)
- 05000333/LER-1983-004, Forwards LER 83-004/03L-0 (← links)
- ML20079M095 (redirect page) (← links)
- 05000333/LER-1983-005 (redirect page) (← links)
- ML20079L853 (redirect page) (← links)
- 05000333/LER-1983-014, Forwards LER 83-014/03L-0 (← links)
- 05000333/LER-1983-017, Forwards LER 83-017/03L-0 (← links)
- 05000333/LER-1983-015, Forwards LER 83-015/03L-0 (← links)
- 05000333/LER-1983-010, Forwards LER 83-010/03L-0 (← links)
- 05000333/LER-1983-060-03, Incorrect Motor Actuator Installed on RHR Suppression Pool Outboard Isolation Valve During Maint Activities.Cause Not Stated.Replacement Actuator Installed on 840119 (← links)
- 05000333/LER-1983-025-03, /03L-0:on 830810,mgt Review of Surveillance Test Results Revealed Excessive Containment Isolation Valve Closure Times Signed Off as Satisfactory.Caused by Personnel Error.Personnel Counseled (← links)
- 05000333/LER-1983-002-03, /03L-0:on 830109,standby Gas Treatment Sys B Humidity Control Heater Out of Svc for Approx 5 H.Caused by Shorted Silicon Controlled Rectifier to Ground.Silicon Controlled Rectifier Removed (← links)
- 05000333/LER-1983-003-03, /03L-0:on 830111,while Conducting Surveillance Testing on Core Sparger to Reactor Vessel D/P Switches 14DPIS-43A & B,Instrument Setpoints Found to Be Less Conservative than Required.Caused by Instrument Drift (← links)
- 05000333/LER-1983-058-03, /03L-0:on 831128,during Surveillance Testing on HPCI Turbine Steam Line High Flow Instrument 23-DPIS-77, Setpoint Found W/Less than 106 Inches of Water Required. Caused by Instrument Drift.Setpoint Adjusted (← links)
- 05000333/LER-1983-062-03, /03L-0:on 831203,during Surveillance Testing, Calibr Span on Scram Discharge Vol Level Transmitter 03-DPT-231-H Found Out of Spec.Caused by Improperly Sloped Test Vent Tube.Calibr Span Adjusted (← links)
- 05000333/LER-1983-061-03, /03L-0:on 831130,during Surveillance Test F-ST-2R, RHR Svc Water Pump P-1C,mfg by Allis-Chalmers,ran W/High Vibration.Pump Declared Inoperable.Cause Not Stated.Bearing Sleeve,Suction Bell & Line Shaft Replaced (← links)
- 05000333/LER-1983-059-04, /04T-0:on 831129,periphyton Exceeded 10 Times Control Sample for Co-60.Caused by Bioaccumulation Factor for Element.No Radiation Dose to Man Expected (← links)
- 05000333/LER-1983-056-03, /03L-0:on 831114,while Conducting Surveillance Testing,Monitor 17-RM-251C Setpoint Found Less Conservative than Tech Spec Table 3.1-1.Caused by Instrument Drift. Monitor Recalibr (← links)
- 05000333/LER-1983-055-03, /03L-0:on 831104,turbine Steam High Flow Containment Isolation Switch 23-DPIS-76 Setpoint Found Less Conservative than Tech Spec.Caused by Instrument Drift. Setpoint Adjusted (← links)
- 05000333/LER-1983-044-03, /03X-1:on 830930,during Normal Operation,Drywell Continuous Atmosphere (Particulate) Radioactivity Monitoring Sys a & B Side Out of Svc.Side a Hard Downscale Indication Caused by Failed Detector (← links)
- 05000333/LER-1983-054-03, /03L-0:on 831104,steam Leak Occurred in 3/4-inch Pipe to HPCI Header Vent.Caused by Crack in heat-affected Area of Weld on Short Pipe Nipple.Rhr HX Sys Supports Checked to Verify Correct Installation (← links)
- 05000333/LER-1983-057-03, /03L-0:on 831106,during Surveillance Test, Calculation of Reactor Coolant Leakage Rates Inside Primary Containment Not Performed.Caused by Personnel Error.Missing Data Recorded & Personnel Counseled (← links)
- 05000333/LER-1983-053-03, /03L-0:on 830604,baseplate of Snubber Support on Torus Cooling Line Found W/Concrete Anchor Bolts Pulled from Concrete Embedment.Caused by Water Hammer.All Discrepancies Repaired (← links)
- 05000333/LER-1983-052-03, /03L-0:on 831101,during F-ST-48,HPCI Turbine Stop Valve Tripped Shut.Caused by Dirt Under Trip Piston Allowing Hydraulic Oil to Be Dumped from Stop Valve Hydraulic Actuator.Trip Assembly Cleaned (← links)
- 05000333/LER-1983-051-03, /03L-0:on 831025,condensate Storage Tank Low Level Switch 23-LS-74B Setpoint Found Below Tech Spec Min.Caused by Setpoint Drift.Setpoint Immediately Adjusted (← links)
- 05000333/LER-1983-042-03, LPCI Independent Power Supply B Tripped.Caused by Faulty Inverter Leg Assembly. Assembly Replaced & Inverter Tested Satisfactorily (← links)
- 05000333/LER-1983-043-03, /03L-0:on 830927,condensate Storage Tank Low Level Switch 23-LS-74A Failed to Trip at Setpoint of 59.5 Inches Above Tank Bottom.Cause Unknown.Switch Mechanism Will Be Observed Further (← links)
- 05000333/LER-1983-048-03, /03L-0:on 831021,during Normal Operation,Plant Entered 24 H Limiting Condition Due to Control Rod Selection Switch 10-15 Being Inoperable.Caused by Switch Aging.Switch Replaced (← links)
- 05000333/LER-1983-050-03, /03L-0:on 831024,reactor Cleanup Sys Equipment Area High Temp Switch 12-TS-139B Setpoint Found Higher than Tech Spec Max.Caused by Instrument Drift.Setpoint Reset (← links)
- 05000333/LER-1983-046-03, /03L-0:on 831008,plant Entered 24 H Limiting Condition for Operation Due to Control Rod 02-23 Rod Selection Switch Inoperability.Caused by Old Age of Switch. Switch Replaced & Verified Operable (← links)
- 05000333/LER-1983-045-03, /03X-1:on 831004,discovered Surveillance Test F-ST-5B, APRM Instrument Functional Test, Exceeded Tech Spec Requirements by 18 Minutes.Caused by Personnel Error. Surveillance Schedule Updated (← links)
- 05000333/LER-1983-047-03, /03L-0:on 831027,during Surveillance Testing,One of Four Scram Instrument Vol Drain Valves AOV35 Failed to Close within Specified Time Frame.Relaxation of Lower Stroke Time Limit Under Evaluation (← links)
- 05000333/LER-1983-040-03, During Testing of post-accident Sampling Sys,Deuterium & Oxygen Sampling Sys Inoperable.Caused by New Mod.Change to Tech Specs Allowing short-term Isolation Initiated (← links)
- 05000333/LER-1983-039-03, /03L-0:on 830920,main Steam Line Containment Low Pressure Switch Setpoint Found Less Conservative than Tech Spec Requirements.Caused by Instrument Drift.Setpoint Readjusted (← links)
- 05000333/LER-1983-038-03, /03L-0:on 830916,while Performing RHR Motor Operated Valve Operability Surveillance Test F-ST-2C,LPCI Valve 10MOV-25B Stopped in Middle of Open Stroke.Caused by Loosened Motor Pinion & Disloged Key (← links)
- 05000333/LER-1983-031-03, /03L-0:on 830912,two of Five Tested Target Rock Safety/Relief Valves Had Setpoint Values Lower than Allowable Tolerance,Two Had Lift Setpoints Above Tolerance & One Did Not Lift.Valves Refurbished by Vendor (← links)
- 05000333/LER-1983-035-03, /03L-0:on 830909,during Surveillance Testing,Main Steam Line High Flow Switch 02-DPIS-116D Did Not Trip Primary Containment Isolation Sys Logic.Caused by Failed Microswitch.Microswitch Replaced (← links)
- 05000333/LER-1983-033-03, /03L-0:on 830905 & 07,during Startup & Ascension to Power While Inerting Drywell,Torus Level Fell Below Tech Spec Requirements.Caused by Water Block in Dry Leg of Level Transmitter.Dry Leg Vented (← links)
- 05000333/LER-1983-022-03, /03X-1:on 830607,during Performance of Local Leak Rate Testing,Containment Spray Penetration X-39A Found W/Leakage Exceeding 0.6 La.Caused by Normal Use.Valve Seal, Disc &/Or Seat Surfaces Replaced (← links)
- 05000333/LER-1983-030-03, /03L-0:on 830830,AE Advised That Emergency Diesel Generators Could Be Rendered Inoperable If Diesel Exhaust Sys Subjected to Tornado Wind Loads.Exhaust Sys Modified in Lieu of Performing Study (← links)
- 05000333/LER-1983-026-03, /03L-0:on 830819,during Special Insp of Main Steam Line Pipe Supports & Restraints Outboard of Containment Msiv,Support Frame Above Trunnion H29-351 Found Bent.Caused by Insufficient Design Clearance (← links)
- 05000333/LER-1983-065-03, /03L-0:on 831216,while Conducting Surveillance Testing of Main Steam Line Radiation Monitors,Setpoint of Monitor 17-RM-251C Found Less Conservative than Tech Spec. Caused by Instrument Drift.Setpoint Adjusted (← links)
- 05000333/LER-1983-067-03, /03L-0:on 831228,while Conducting Surveillance Testing on RCIC Turbine Steam Line High Flow Switch 13-DPIS-84,setpoint Found Less Conservative than Required. Caused by Instrument Drift.Setpoint Corrected (← links)
- 05000333/LER-1983-063-03, /03L-0:on 831215,during Normal Operation,Lpci Independent Power Supply a Tripped.Cause Undetermined.Power Supply Returned to Svc (← links)
- 05000333/LER-1983-004-03, /03L-0:on 830117,control Rod 18-27 Found Uncoupled & Would Not Recouple.Caused by Bent Uncoupling Rod in Control Rod Drive Mechanism & Loose Inner Filter.Mechanism Replaced W/Rebuilt Unit (← links)