Pages that link to "05000333/LER-1982-022, Forwards LER 82-022/03L-0"
Jump to navigation
Jump to search
The following pages link to 05000333/LER-1982-022, Forwards LER 82-022/03L-0:
Displayed 50 items.
- 05000333/LER-1982-025, Forwards LER 82-025/03L-0 (← links)
- 05000333/LER-1982-026, Forwards LER 82-026/03L-0 (← links)
- 05000333/LER-1982-023, Forwards LER 82-023/03L-0 (← links)
- 05000333/LER-1982-012, Forwards LER 82-012/03L-0 (← links)
- 05000333/LER-1982-013, Forwards LER 82-013/03L-0 (← links)
- 05000333/LER-1982-010, Forwards LER 82-010/03L-0 (← links)
- 05000333/LER-1982-009, Forwards LER 82-009/03L-0 (← links)
- 05000333/LER-1982-011, Forwards LER 82-011/03L-0 (← links)
- 05000333/LER-1982-008, Forwards LER 82-008/03L-0 (← links)
- 05000333/LER-1982-042, Forwards LER 82-042/03L-0 (← links)
- 05000333/LER-1982-060, Forwards LER 82-060/04T-0 (← links)
- 05000333/LER-1982-056, Forwards LER 82-056/03L-0 (← links)
- 05000333/LER-1982-053, Forwards LER 82-053/03L-0 (← links)
- 05000333/LER-1982-054, Forwards LER 82-054/03L-0 (← links)
- 05000333/LER-1982-055, Forwards LER 82-055/03L-0 (← links)
- 05000333/LER-1982-058, Forwards LER 82-058/04T-0 (← links)
- 05000333/LER-1982-041, Forwards LER 82-041/03L-0 (← links)
- 05000333/LER-1982-034, Forwards LER 82-034/03X-1 (← links)
- 05000333/LER-1982-040, Forwards LER 82-040/04T-0 (← links)
- 05000333/LER-1982-037, Forwards LER 82-037/03L-0 (← links)
- 05000333/LER-1982-036, Forwards LER 82-036/03L-0 (← links)
- 05000333/LER-1982-038, Forwards LER 82-038/03L-0 (← links)
- 05000333/LER-1982-033, Forwards LER 82-033/03L-0 (← links)
- 05000333/LER-1982-032, Forwards LER 82-032/03L-0 (← links)
- 05000333/LER-1982-031, Forwards LER 82-031/03L-0 (← links)
- 05000333/LER-1982-029, Forwards LER 82-029/03L-0 (← links)
- 05000333/LER-1982-018, Forwards LER 82-018/03X-1 (← links)
- 05000333/LER-1982-049, Forwards LER 82-049/03L-0 (← links)
- 05000333/LER-1982-052, Forwards LER 82-052/03L-0 (← links)
- 05000333/LER-1982-045, Forwards LER 82-045/03L-0 (← links)
- 05000333/LER-1982-059, Forwards LER 82-059/03L-0 (← links)
- ML20079F859 (redirect page) (← links)
- 05000333/LER-1982-022 (redirect page) (← links)
- 05000333/LER-1982-004, Forwards LER 82-004/03X-1 (← links)
- 05000333/LER-1982-051, Forwards Updated LER 82-051/03L-1 (← links)
- 05000333/LER-1982-028, Forwards Updated LER 82-028/03X-1 (← links)
- 05000333/LER-1982-027, Forwards LER 82-027/03L-0 (← links)
- 05000333/LER-1982-059-03, /03L-0:on 821226,MSIV B Outboard 10% Switch Would Not Reset When Tested Per Tech Spec 3.1-1.Caused by Mismatch Between Activation & Striker Plate in Reset Direction of Valve Travel.Striker Plate Mechanically Reworked (← links)
- 05000333/LER-1982-022-03, /03L-0:on 820501,during Normal Operation,Emergency Diesel Generator D Declared Inoperable W/A Also Inoperable Requiring Reactor Shutdown Initiation.Cause Not Determined. Generators Declared Operable & Returned to Svc (← links)
- 05000333/LER-1982-004-03, /03X-1:on 820227,during Normal Shutdown,Part of Logic Sys Functional Tests Required by Tech Spec Table 4.2.1 Had Not Been Performed.Caused by Procedure Error.Procedure Revised & Surveillance Performed (← links)
- 05000333/LER-1982-051-03, While Conducting Surveillance Testing on Reactor Low Water Scram Switch 02-3-LIS-101D,setpoint Found Less Conservative than Required.Caused by Instrument Drift.Setpoint Adjusted (← links)
- 05000333/LER-1982-050-03, /03L-0:on 821109,scram Discharge Vol Rod Block Level Surveillance Test Not Performed within 7 Days of Reactor Startup,Per Tech Spec.Caused by Failure to Enter Frequency Statement in Procedure During Review of Amend 62 (← links)
- 05000333/LER-1982-018-03, /03X-1:on 820419,surveillance Testing Indicated Four Smoke Detectors Inoperable.Caused by Failure to Terminate Connecting Cabling Properly,Due to Inadequate Procedure Preparation & Review.Procedure to Be Revised (← links)
- 05000333/LER-1982-044-03, /03L-0:on 820909,motor Operator Electrical Breaker Tripped While Attempting to Cycle LPCI Injection Valve. Caused by Electrical Motor Fault Resulting in Isolation Failure Created During Attempted Valve Cycling (← links)
- 05000333/LER-1982-049-03, /03L-0:on 821027,during Tech Spec Surveillance Requirement Review,Scram Discharge Vol Vents & Drains Not Cycled on Quarterly Basis.Caused by Supervisory Personnel Error.Addl Surveillance Procedure Developed (← links)
- 05000333/LER-1982-052-03, /03L-0:on 821110,HPCI Turbine High Exhaust Diaphragm Pressure Switch 23-PS-86B Setpoint Found to Be Less Conservative than Required Setting.Caused by Instrument Drift.Switch Setpoint Adjusted within Tech Spec Limit (← links)
- 05000333/LER-1982-045-03, /03L-0:on 821006,isolation Valves 02-39 & 40 Associated W/Penetration X-41 Failed to Isolate on All Signals.Caused by Failure to Update FSAR & Tech Specs to Reflect Change in Signals During Const.Valves Closed (← links)
- 05000333/LER-1982-048-03, /03L-0:on 821020,number 4 Plant 115-kV Lines Removed from Svc for 2-h.Caused by Extension Cord Being Dropped Across Two Phases of Line.Line de-energized,fault Cleared & Line re-energized (← links)
- 05000333/LER-1982-046-03, /03L-0:on 821007,intermediate Range Monitor B Inoperative Trip Function Did Not Trip B Side RPS Logic on Simulated Downscale Signal.Caused by Failed Diode in Mean Squared Analog Mondule.Diode Replaced (← links)
- 05000333/LER-1982-028-03, Drywell Equipment Drain Sump Flow Integrator Found Out of Calibr & Could Not Be Adjusted.Caused by Abnormal Friction in Drive Gear Train.New Gears Purchased to Rebuild Unit (← links)