Pages that link to "05000333/LER-1982-021, Forwards LER 82-021/03X-1"
Jump to navigation
Jump to search
The following pages link to 05000333/LER-1982-021, Forwards LER 82-021/03X-1:
Displayed 50 items.
- 05000333/LER-1982-014, Forwards LER 82-014/03X-1 (← links)
- 05000333/LER-1982-025, Forwards LER 82-025/03L-0 (← links)
- 05000333/LER-1982-026, Forwards LER 82-026/03L-0 (← links)
- 05000333/LER-1982-024, Forwards LER 82-024/03L-0 (← links)
- 05000333/LER-1982-023, Forwards LER 82-023/03L-0 (← links)
- 05000333/LER-1982-012, Forwards LER 82-012/03L-0 (← links)
- 05000333/LER-1982-013, Forwards LER 82-013/03L-0 (← links)
- 05000333/LER-1982-010, Forwards LER 82-010/03L-0 (← links)
- 05000333/LER-1982-009, Forwards LER 82-009/03L-0 (← links)
- 05000333/LER-1982-011, Forwards LER 82-011/03L-0 (← links)
- 05000333/LER-1982-008, Forwards LER 82-008/03L-0 (← links)
- 05000333/LER-1982-007, Forwards LER 82-007/03L-0 (← links)
- ML20063D295 (redirect page) (← links)
- 05000333/LER-1982-021 (redirect page) (← links)
- 05000333/LER-1982-035, Forwards LER 82-035/03L-0 (← links)
- 05000333/LER-1982-029, Forwards LER 82-029/03L-0 (← links)
- 05000333/LER-1982-030, Forwards LER 82-030/03L-0 (← links)
- 05000333/LER-1982-021, Forwards LER 82-021/03L-0 (redirect page) (← links)
- 05000333/LER-1982-043, Forwards LER 82-043/03L-0 (← links)
- 05000333/LER-1982-045, Forwards LER 82-045/03L-0 (← links)
- 05000333/LER-1982-059, Forwards LER 82-059/03L-0 (← links)
- ML20079F676 (redirect page) (← links)
- 05000333/LER-1982-051, Forwards Updated LER 82-051/03L-1 (← links)
- 05000333/LER-1982-028, Forwards Updated LER 82-028/03X-1 (← links)
- 05000333/LER-1982-050-03, /03L-0:on 821109,scram Discharge Vol Rod Block Level Surveillance Test Not Performed within 7 Days of Reactor Startup,Per Tech Spec.Caused by Failure to Enter Frequency Statement in Procedure During Review of Amend 62 (← links)
- 05000333/LER-1982-044-03, /03L-0:on 820909,motor Operator Electrical Breaker Tripped While Attempting to Cycle LPCI Injection Valve. Caused by Electrical Motor Fault Resulting in Isolation Failure Created During Attempted Valve Cycling (← links)
- 05000333/LER-1982-052-03, /03L-0:on 821110,HPCI Turbine High Exhaust Diaphragm Pressure Switch 23-PS-86B Setpoint Found to Be Less Conservative than Required Setting.Caused by Instrument Drift.Switch Setpoint Adjusted within Tech Spec Limit (← links)
- 05000333/LER-1982-045-03, /03L-0:on 821006,isolation Valves 02-39 & 40 Associated W/Penetration X-41 Failed to Isolate on All Signals.Caused by Failure to Update FSAR & Tech Specs to Reflect Change in Signals During Const.Valves Closed (← links)
- 05000333/LER-1982-047-03, /03L-0:on 821007,reactor Scram Occurred Due to Blockage of D Main Steam Line.D Inboard MSIV Disc Separated from Stem.Caused by Shearing of anti-rotation Pin Allowing Pilot Disc to Unscrew & Part from Stem (← links)
- 05000333/LER-1982-047, Forwards LER 82-047/03L-0 (← links)
- 05000333/LER-1982-028-03, Drywell Equipment Drain Sump Flow Integrator Found Out of Calibr & Could Not Be Adjusted.Caused by Abnormal Friction in Drive Gear Train.New Gears Purchased to Rebuild Unit (← links)
- 05000333/LER-1982-043-03, /03L-0:on 820902,MSIV D Inboard 10% Switch Would Not Reset When Tested to Satisfy Tech Spec 3.1-1.Caused by Drift Between Switch Operator & Striker Plate.Switch Striker Plate Modified (← links)
- 05000333/LER-1982-042-03, /03L-0:on 820826,testing of Control Rod Hydraulic Control Unit Accumulator Pressure & Level Switches & Pressure Indication Revealed 68 of 411 Instruments Out of Calibr or Not Operating Properly.Caused by Instrument Drift (← links)
- 05000333/LER-1982-054-03, /03L-0:on 821213,difficulty Experienced in Initiating Trip on DPIS-76 & Venting Low Pressure Side of DPIS-77 During Surveillance Testing.Caused by Incomplete Instrument Surveillance Procedure.Procedure Revised (← links)
- 05000333/LER-1982-058-04, /04T-0:on 821217,defected Mn-54 Level in Mollusk Samples Exceeded 10 Times Control Location Sample Level. Possibly Caused by High Bioaccumulation Factor,Resulting in Accumulation of Trace Quantities in Mollusks (← links)
- 05000333/LER-1982-034-03, /03X-1:on 820713,instrument Flow Components Drift Resulted in Nonconservative Calculation of Core Thermal Power.Rated Thermal Power Limit Exceeded on Approx 75 Days of Cycle 5 Operation.Caused by Instrument Drift (← links)
- 05000333/LER-1982-027, Forwards LER 82-027/03L-0 (← links)
- 05000333/LER-1982-056-03, /03L-0:on 821215,LPCI Inverter a Tripped When Power Transferred to Maint Supply,Per Tech Spec 3.9.F. Redundant Sys Verified Operable.Caused by Failed Gate Timing Control Card.Card Returned to Vendor for Analysis & Repair (← links)
- 05000333/LER-1982-055-03, /03L-0:on 821214,turbine Steam High Flow Containment Isolation Switch 13-DPIS-84 Setpoint Found Less Conservative than Tech Specs.Caused by Instrument Drift. Setpoint Adjusted to within Required Value (← links)
- 05000333/LER-1982-021-03, /03X-1:on 820501,emergency Diesel Generator a Found Inoperable Due to Voltage & Frequency Fluctuations. Cause Attributed to Momentary Grounds on a 125-volt Dc Sys (← links)
- 05000333/LER-1982-040-04, /04T-0:on 820810,environ Radiological Sampling Resulted in Anomalous Result in Spring Mollusk Samples. Possibly Caused by High Bioaccumulation Factor Due to Concentration of Manganese in Lake (← links)
- 05000333/LER-1982-035-03, /03L-0:on 820804,while Inerting Drywell During Startup,Indicated Torus Level Was Below Tech Spec.Caused by Displacement of Water in Downcomers During Inerting.Tech Spec Amend to Be Submitted (← links)
- 05000333/LER-1982-037-03, /03L-0:on 820730,during Ascension to Power, Abnormally High Tail Piece Temps Indicated on Interim Target Rock Model Safety Relief Valve F.Probably Caused by Valve Leakage from Pilot Seat.Daily Surveillance Initiated (← links)
- 05000333/LER-1982-033-03, /03L-0:on 820706,reserve Power Breaker 10022 Was Open for Approx 4 Minutes,Rendering Light House Hill Line 3 Unavailable.Caused by Lightning Strike.No Corrective Action Required (← links)
- 05000333/LER-1982-029-03, /03L-0:on 820707,during Normal Operation,Main Steam Line Radiation Monitor a Tripped in Inoperable Condition When Required to Be Operable.Caused by Loose Instrument High Voltage Fuse.Fuse Reinstalled (← links)
- 05000333/LER-1982-030-03, /03L-0:on 820709,rod Block Monitor B Found Out of Calibr.Caused by Instrument Drift.Monitor Recalibr (← links)
- 05000333/LER-1982-027-03, /03L-0:on 820616,recirculation Flow Transmitter 02-FT-110D Found Out of Calibr Causing Small Error in Half of Average Power Range Monitor Setpoint.Caused by Instrument Drift.Instrument Recalibr (← links)
- 05000333/LER-1982-020, Forwards LER 82-020/03L-0 (← links)
- 05000333/LER-1982-019-03, /03L-0:on 820423,control Rod 26-51 Could Not Be Selected to Move & Could Not Be Normally Inserted or Withdrawn.Caused by Broken Wire on Select Switch 26-51. Switch Repaired (← links)
- 05000333/LER-1982-019, Forwards LER 82-019/03L-0 (← links)
- 05000333/LER-1982-018-03, /03L-0:on 820419,found Four Improperly Terminated Smoke Detectors.Caused by Procedure Error Resulting in Failure to Terminate Detectors.Fire Watch Established. Investigation Continuing (← links)
- 05000333/LER-1982-018, Forwards LER 82-018/03L-0 (← links)
- 05000333/LER-1982-005, RO:82-005 on 820315,oxygen Concentration Spec for Drywell Found Exceeded Due to Breathing Air Being Improperly Lined Up to Drywell (← links)
- 05000333/LER-1982-017-03, /03L-0:on 820402,MSIV 10% Closure Position Switches on Two Valves Did Not Trip When Tested.Caused by Mechanical Drift of Valve Position Switch Operating Cams. Adjustment Made (← links)
- 05000333/LER-1982-017, Forwards LER 82-017/03L-0 (← links)
- 05000333/LER-1982-016-03, /03L-0:on 820329,reactor Core Isolation Cooling Sys Was Intentionally Made Inoperable to Allow Repair of Dc Ground on Sys Logic Circuits.Ground Caused by Failed Sump Pump Which Allowed Valve Pit Flooding.Pump Replaced (← links)
- 05000333/LER-1982-016, Forwards LER 82-016/03L-0 (← links)
- 05000333/LER-1982-005-01, /01X-1:on 820315,during Normal Operation, Containment Oxygen Concentration Exceeded 4% Limit for Approx 6-h.Caused by Personnel Error.Startup Checkoff List Revised (← links)
- 05000333/LER-1982-015-03, /03L-0:on 820327,during Normal Operation,Personnel Noted Sudden Increase in Indicated Containment Oxygen Concentration on Oxygen Analyzer A.Caused by Leakage on Inlet Side of Sample Sys for Analyzer (← links)
- 05000333/LER-1982-015, Forwards LER 82-015/03L-0 (← links)
- 05000333/LER-1982-006-03, /03L-0:on 820306,during Normal Startup,Pressure Suppression Pool Water Level Was Found 0.4 Inches Below Tech Spec Limit.Caused by Personnel Error.Water Level Corrected.Tech Spec Changes Considered (← links)
- 05000333/LER-1982-006, Forwards LER 82-006/03L-0 (← links)
- 05000333/LER-1982-004, Forwards LER 82-004/03L-0 (← links)
- 05000333/LER-1982-001, Forwards LER 82-001/01T-0 (← links)
- 05000333/LER-1982-003, Forwards LER 82-003/01T-0 (← links)
- 05000333/LER-1982-002, Forwards LER 82-002/03L-0 (← links)
- 05000333/LER-1982-057-03, /03L-0:on 821216,during Normal Operation,Reactor Scrammed on High Neutron Flux on Power Range Monitors. Caused by Reactor Pressure Spike Created by Sudden Closure of One MSIV Due to Improper Maint.Procedure Changed (← links)
- 05000333/LER-1982-057, Forwards LER 82-057/03L-0 (← links)