- 05000333/LER-1981-079-03, /03L-0:on 811116,sample of Standby Gas Treatment Charcoal Was Less than 99% Efficient in Removing Methyl Iodide.Apparently Caused by Age of Charcoal.Charcoal Replaced (← links)
- 05000333/LER-1981-079 (redirect page) (← links)
- 05000333/LER-1981-078-03, /03L-0:on 811103,during Local Leak Rate Tests, Drywell Purge Exhaust Outboard Isolation Valve 27-AOV-114 Found W/Leakage That May Exceed Tech Spec.Cause Undetermined.Valves May Require Repair (← links)
- 05000333/LER-1981-078, Forwards LER 81-078/03L-0 (← links)
- 05000333/LER-1981-077-03, /03L-0:on 811027,emergency Svc Water Pump B Failed to Automatically Start When Emergency Diesel Generator D Started.Caused by High Resistance Contact on EDG-D.Contact Cleaned (← links)
- 05000333/LER-1981-076-03, /03L-0:on 811026,during Normal Operation,Smoke Detectors Would Not Sound in Control Room.Caused by Failure of Multiplexer Transmitter Extender Module.Replaced Module & Restored Sys (← links)
- 05000333/LER-1981-076, Forwards LER 81-076/03L-0 (← links)
- 05000333/LER-1981-073-03, /03X-1:on 811007,during Surveillance,Condensate Storage Tank Level Switch 23-LIS-75B Was Damaged.Caused by Screw Catching & Damaging Wire Insulation When Instrument Was Partially Disassembled.Switch Repaired & Calibr (← links)
- 05000333/LER-1981-073, Forwards LER 81-073/03X-1 (← links)
- 05000333/LER-1981-075-03, /03L-0:on 811015,shutdown Cooling Permissive Switch Found Set Below Tech Spec Range.Caused by Instrument Drift.Switch Recalibr & Weekly Surveillance Instituted Until Stable Performance Demonstrated (← links)
- 05000333/LER-1981-072, Forwards LER 81-072/03L-0 (← links)
- 05000333/LER-1981-071, Forwards LER 81-071/03L-0 (← links)
- 05000333/LER-1981-070-04, /04T-0:on 810925,environ Radiological Sampling Resulted in Anomalous Results for Periphyton Samples. Calculated Dose to Man Will Be Included in 1981 Radiological Environ Surveillance Rept (← links)
- 05000333/LER-1981-070, Forwards LER 81-070/04T-0 (← links)
- 05000333/LER-1981-066-03, /03L-0:on 810816,during Startup,Heatup Rate Limit Was Exceeded.Caused by Personnel Error.Power Reduced & Steam Flow Increased (← links)
- 05000333/LER-1981-066, Forwards LER 81-066/03L-0 (← links)
- 05000333/LER-1981-068-03, /03L-0:on 810824,while Conducting Surveillance to Satisfy Tech Spec Table 4.2-2,HPCI High Steam Flow Differential Pressure Switch Was Found Set Above Tech Specs. Caused by Instrument Drift.Instrument Recalibr (← links)
- 05000333/LER-1981-067, Forwards LER 81-067/03L-0 (← links)
- 05000333/LER-1981-060-03, /03L-0:on 810810,safety Relief Valve Found Set at Different Setpoint than Allowed by Tech Spec.Caused by Personnel Error.Tech Spec Revised to Allow Interim Operation W/Valve of Different Setpoint (← links)
- 05000333/LER-1981-058-04, /04T-0:on 810729,environ Radiological Sampling Showed Abnormal Results in Fish & Poultry.Possibly Caused by Contamination Either During Field Collection or in Analytical Lab.Final Results Submitted in 1981 Rept (← links)