- 05000333/LER-1980-073-03, /03L-0:on 800815 During Surveillance,Offgas Radiation Monitor B Found Out of Calibr.Caused by Instrument Drift & Detector Aging.Adjusted & Restored Monitor to Operable Status 3 Days After Discovery (← links)
- 05000333/LER-1980-073 (redirect page) (← links)
- 05000333/LER-1980-066-03, /03L-0:on 800805,during Normal Shutdown,Conducting Surveillance Procedure F-ISP-8,core Spray Sys Pipe Break Detection Switches 14-DPIS-43A & 43B Found Set Greater than Limit.Caused by Instrument Drift.Instruments Recalibr (← links)
- 05000333/LER-1980-066, Forwards LER 80-066/03L-0 (← links)
- 05000333/LER-1980-065-03, /03T-0:on 800814,during Normal Operations,While Inerting Primary Containment,Standby Gas Treatment Sys A&B Found Inoperable.Caused by Blocked Drain Line Allowing Water to Accumulate in Line Until Fans Could Not Discharge (← links)
- 05000333/LER-1980-069-03, /03L-0:on 800807,during Normal Shutdown,While Conducting Surveillance Test F-ST-22A,auto Depressurization Sys Timer Found Set Below Limit.Caused by Setpoint Drift. Timer Adjusted & Returned to Svc (← links)
- 05000333/LER-1980-069, Forwards LER 80-069/03L-0 (← links)
- 05000333/LER-1980-068-03, /03L-0:on 800806,during Normal Cold Shutdown, Conducting Instrument Surveillance F-ISP-15,drywell Drain Sump Pump Flow Transmitter Found Out of Tolerance.Caused by Instrument Drift.Instrument Recalibr (← links)
- 05000333/LER-1980-068, Forwards LER 80-068/03L-0 (← links)
- 05000333/LER-1980-067-03, /03L-0:on 800805,while Conducting Instrument Surveillance Check,Steam Line Low Pressure Switches Found Set Higher than 100 Psig Limit.Caused by Instrument Drift. Instruments Calibr & Returned to Svc (← links)
- 05000333/LER-1980-067, Forwards LER 80-067/03L-0 (← links)
- 05000333/LER-1980-063-03, /03L-0:on 800717,during Normal Shutdown, Surveillance Revealed That Average Power Range Monitor E Indicated 48 When Required to Read Between 49 & 51.Caused by Instrument Drift.Monitor Recalibr (← links)
- 05000333/LER-1980-063, Forwards LER 80-063/03L-0 (← links)
- 05000333/LER-1980-061-03, /03L-0:on 800714,during Shutdown,Functional Test of Hydraulic Snubbers Revealed Two Snubbers Which Failed Lockup & bleed-rate Values.Caused by Normal Wear.Snubbers Were Replaced (← links)
- 05000333/LER-1980-057-03, /03L-0:on 800628,during Normal Shutdown,One Cell in Each 24 Volt Battery for Diesel Fire Pump Failed to Meet Min Specific Gravity Requirements of Surveillance Test. Caused by Charger Being Out of Svc During Surveillance (← links)