Pages that link to "05000324/LER-1982-140, Forwards LER 82-140/03L-0"
Jump to navigation
Jump to search
The following pages link to 05000324/LER-1982-140, Forwards LER 82-140/03L-0:
Displayed 15 items.
- ML20083M170 (redirect page) (← links)
- 05000324/LER-1982-140 (redirect page) (← links)
- 05000324/LER-1982-095, Forwards LER 82-095/03L-0 (← links)
- 05000325/LER-1982-101, Forwards LER 82-101/03L-0 (← links)
- 05000324/LER-1982-140-03, /03L-0:on 821221,primary Containment Atmosphere Oxygen Analyzer 2-CAC-AT-1263-2 Showed Step Increase in Drywell Oxygen Concentration.Caused by Zero Shift Due to Analyzer Being Out of Calibr & by Small Piping Leak (← links)
- 05000325/LER-1982-139-03, /03L-0:on 821114,HPCI Sys Rendered Inoperable When HPCI Steamline Flow High Channel B Isolation Occurred During Operability Test.Caused by Shorted Positioning Coil in HPCI Speed Control Electrohydraulic Governing Regulator A (← links)
- 05000324/LER-1982-052-03, Surveillance Revealed Makeup Demineralized Water Tank Inventory Below Stds.Caused by Isolated Fire Protection Water Tank Makeup Supply Due to Planned Maint.Makeup to Tank Restored (← links)
- 05000324/LER-1982-095-03, /03L-0:on 820903,discovered That Most Recent ILRT Exceeded Specified Testing Interval.Caused by Improper Scheduling.Scheduling Program Revised to Reflect Correct Scheduling Criteria (← links)
- 05000325/LER-1982-101-03, /03L-0:on 820920,valve Time Testing Not Covered in Operability Test of Loops a & B of Lpci/Rhr Sys PTS 08.2.2C & 26.Caused by Personnel Oversight During Procedural Development.Procedures Revised (← links)
- 05000325/LER-1982-057-03, /03L-0:on 820625,primary Containment Atmosphere Oxygen analyzer,1-CAC-AT-1259,indicated Unexpected Upscale Drywell Oxygen Concentration.Caused by Failure of Analyzer Electromagnetic Unit Photocell Light Due to End of Life (← links)
- 05000325/LER-1982-074-03, /03L-0:on 820623,electrolyte Level in Pilot Cell of Div II Battery 1B-1 Found Higher than Max Level Mark on Cell.Caused by Battery Room Ambient Temp Increase Following Filling to Max Level Mark (← links)
- 05000324/LER-1982-022-03, /03L-0:on 820218,isolating Function of Transient in-core Probe a Guide Tube Primary Containment Isolation Ball Valve Became Inoperable During Monitor Calibr & Base Distribution.Caused by Probe Not Fully Retracting (← links)
- 05000324/LER-1982-014-03, /03L-0:on 820117,primary Containment Atmospheric Oxygen analyzer,2-CAC-AT-1263-2,did Not Show Expected Trend in Drywell Concentration.Caused by Analyzer Components Heating Up Due to Stuck Thermostat Electrical Contacts (← links)
- 05000324/LER-1982-017-03, /03L-0:on 820118,remote Shutdown Panel Suppression Chamber Water Temp Recorder 2-CAC-TR-778 Did Not Record Temps.Caused by Print Head Actuation Linkage Separating from Solenoid Due to Lack of Spring Tension (← links)
- 05000324/LER-1982-024-01, /01T-0:on 820205,control Bldg Emergency Ventilation Sys Trains Would Not Isolate Upon Receipt of Chlorine Isolation Signal When Sys Control Switch Was in on Position.Cause Undetermined.Design Review Underway (← links)