- 05000321/LER-1980-006-03, /03L-0:on 800113,one Standby Gas Treatment Sys Rendered Inoperable W/Both Units in Power Operation.Unit Not Proven Operable within Required 4-h.Caused by Inability to Prove Filter Train Operable within 4-h (← links)
- 05000366/LER-1980-029, Forwards LER 80-029/01T-0 (← links)
- 05000321/LER-1980-018-03, /03L-0:on 800207,during Normal,Full Power Operation,Hydraulic Control Unit Accumulator 42-23 Received Low Pressure Alarm.Caused by Failure of Nitrogen Cartridge Valve from Wear Due to Constant Use (← links)
- 05000321/LER-1980-015, Forwards LER 80-015/03L-0 (← links)
- 05000366/LER-1980-012, Forwards LER 80-012/03L-0 (← links)
- 05000366/LER-1980-014-03, /03L-0:on 800204,while Performing HNP-2-3054, Average Power Range Monitor C Failed.Caused by Instrument Drift.Instrument Adjusted Per Procedure & Returned to Svc (← links)
- 05000366/LER-1980-014, Forwards LER 80-014/03L-0 (← links)
- 05000321/LER-1980-014, Forwards LER 80-014/03L-0 (← links)
- 05000366/LER-1980-013-03, /03L-0:on 800203,while Maint Was Performed on 2082-K002 Static Inverter,Emergency Control Transfer Switch Was Placed in Emergency Position.Reactor Core Isolation Cooling Was Rendered Inoperable.Caused by Personnel Error (← links)
- 05000366/LER-1980-013, Forwards LER 80-013/03L-0 (← links)
- 05000321/LER-1980-017-03, /03L-0:on 800201,while Performing MSIV Closure Instrumentation Ft&C,Scram Relays IC71-K3G & H Found de-energized W/Associated MSIVs Fully Open.Caused by Loose Limit Switch on Actuating Arm.Arm Reset & Tightened (← links)
- 05000321/LER-1980-017, Forwards LER 80-017/03L-0 (← links)
- 05000321/LER-1980-011-03, /03L-0:on 800120,while at Steady State Power, torus-to-drywell Differential Pressure recorder,LT48-R631B Had Low Reading.Cause Not Stated (← links)
- 05000321/LER-1980-011, Forwards LER 80-011/03L-0 (← links)
- 05000366/LER-1980-015-03, /03L-0:on 800131,review of Surveillance Requirements Revealed 12 & 18-month Surveillances for Tech Spec Sections 4.7.6.1e & 4.7.6.1.f.3 Not Performed.Caused by Misinterpretation of Tech Specs (← links)
- 05000366/LER-1980-015, Forwards LER 80-015/03L-0 (← links)
- 05000321/LER-1980-006 (redirect page) (← links)
- 05000366/LER-1980-004-03, /03L-0:on 800118,during Steady State Power Operation Hydrogen Recombiner Inlet Valve 2T49-F003A Did Not Open.Caused by a Failed Torque Switch.Sys Returned to Operation After Switch Was Replaced (← links)
- 05000366/LER-1980-004, Forwards LER 80-004/03L-0 (← links)
- 05000321/LER-1980-012-03, /03L-0:on 800122,while Reactor Core Isolation Cooling Sys Was Tagged Out for Maint,Hpci Was Found Inoperable,Requiring Orderly Shutdown.Caused by Leak in Line to HPCI Booster Pump Discharged Pressure Gauge (← links)
- 05000321/LER-1980-012, Forwards LER 80-012/03L-0 (← links)
- 05000321/LER-1980-007-03, /03L-0:on 800114,while Testing Standby Svc Water Pump,Pump Would Not Meet Criteria.Caused by Disengagement of Pump First Stage Impeller Lock Collet.Lock Collet Replaced & Pump Reinstalled (← links)
- 05000366/LER-1980-007, Forwards LER 80-007/01T-0 (← links)
- 05000321/LER-1980-013-03, /03L-0:on 800127,during Steady State Power Operation,A Reactor Recirculation Pump 1B31-COO1A Tripped. Caused by Ground in Pump Control Circuit That Interlocks Pump to Suction Valve Position (← links)
- 05000366/LER-1980-016-03, /03L-0:on 800130,w/reactor in Run Mode,Auxiliary Oil Pump Feeder Breaker Tripped While HPCI Auxiliary Oil Pump Was Running to Obtain Oil Sample.Caused by Failure of Coil of Time Delay Relay.Coil Was Replaced (← links)
- 05000321/LER-1980-013, Forwards LER 80-013/03L-0 (← links)
- 05000366/LER-1980-016, Forwards LER 80-016/03L-0 (← links)
- 05000321/LER-1980-016-03, /03L-0:on 800129,investigation of IE Bulletin 79-27 Revealed That Supply Breakers Control Power to Meter Control Ctr & Mode of Operation Were in Error.Caused by Design Error.Breaker Control Switches Placed in Manual (← links)
- 05000321/LER-1980-016, Forwards LER 80-016/03L-0 (← links)
- 05000366/LER-1980-010-03, /03L-0:on 800131,during Reactor Startup,At 58% Power,Max Total Peaking Factor Was Calculated at 3.0 Compared to Design Value of 2.38.Caused by Lower than Normal Xenon Distribution During Startup (← links)
- 05000366/LER-1980-010, Forwards LER 80-010/03L-0 (← links)
- 05000366/LER-1980-009-03, /03L-0:on 800130,while Performing Procedure HNP-2-33-3,HPCI Min Flow Valve 2E41-F012 Failed to Close. Caused by Sticking Switch Contacts on Flow Switch 2E41-N006. Switch Contacts Cleaned & Procedure HNP-2-3303 Performed (← links)
- 05000366/LER-1980-009, Forwards LER 80-009/03L-0 (← links)
- 05000366/LER-1980-002-01, /01T-0:on 800128,during Cold Shutdown,Ae Notified Util That Single Mode Failure Existed for Torus Gravity Fill Isolation Valve 2G51-F013.Caused by Design Deficiency. Standing Order Issued (← links)
- 05000366/LER-1980-104-03, /03L-0:on 800711,while in Normal Shutdown mode,4 Kv Emergency Switchgear 2F Normal Supply Breaker Tripped & Swapped to Alternate Supply Breaker Which Also Tripped. Caused by Missing Jumper Resulting from Const Fault (← links)
- 05000366/LER-1980-104, Forwards LER 80-104/03L-0 (← links)
- 05000366/LER-1980-102-03, /03L-0:on 800711,surveillance Procedure HNP-2- 3456,reactor Protection Sys Motor Generator Set Overvoltage Undervoltage & Underfrequency Relays Ft&C,Not Completed by midnight,800710.Caused by Limited Time Allowed for Process (← links)
- 05000366/LER-1980-102, Forwards LER 80-102/03L-0 (← links)
- 05000366/LER-1980-005-03, /03L-0:on 800119,during Power Operation,Tech Specs 4.8.1.1.1.a & 4.8.1.1.2a4 for Electrical Power Sources Were Not Performed within 1-h.Caused by Personnel Misinterpretation of Tech Spec Requirements (← links)
- 05000366/LER-1980-005, Forwards LER 80-005/03L-0 (← links)
- 05000321/LER-1980-002, Forwards LER 80-002/03L-0 (← links)
- 05000366/LER-1980-003-03, /03L-0:on 800117,while Applying Equalizing Charge to 125/250-volt Dc Station Svc Batteries,Hpci Automatic Flow Control Power Inverter Tripped.Caused by Instrument Drift. Instrument Recalibr Satisfactorily (← links)
- 05000366/LER-1980-003, Forwards LER 80-003/03L-0 (← links)
- 05000321/LER-1980-008-03, /03L-0:on 800115,during Steady State Power Operation,Secondary Containment Integrity Violated When Personnel Opened 164-ft Elevation Reactor Bldg & Turbine Bldg Airlock Doors Simultaneously.Procedure Revised (← links)
- 05000321/LER-1980-008, Forwards LER 80-008/03L-0 (← links)
- 05000321/LER-1980-004, Forwards LER 80-004/03L-0 (← links)
- 05000321/LER-1980-006-03, /03L-0:on 800113,one Standby Gas Treatment Sys Rendered Inoperable W/Both Units in Power Operation.Unit Not Proven Operable within Required 4-h.Caused by Inability to Prove Filter Train Operable within 4-h (← links)
- 05000321/LER-1980-003, Forwards LER 80-003/03L-0 (← links)
- 05000321/LER-1980-005-03, /03L-0:on 800109,w/reactor Mode Switch in Run Mode,Discovered That Surveillance Procedure HNP-1-3007, Turbine Control Valve Fast Closure,Was Not Performed in Grace Period.Caused by Personnel Error (← links)
- 05000321/LER-1980-005, Forwards LER 80-005/03L-0 (← links)