Pages that link to "05000321/LER-1979-015, Forwards LER 79-015/03L-0"
Jump to navigation
Jump to search
The following pages link to 05000321/LER-1979-015, Forwards LER 79-015/03L-0:
Displayed 23 items.
- 05000321/LER-1979-006, Forwards LER 79-006/03L-0 (← links)
- 05000366/LER-1979-023-03, /03L-1 on 790214:while Performing Startup Test Procedure HNP-2-10925 (MSIV Closure),Discovered 2821-FO28A Outboard MSIV Closed in 2-s.Caused by Failure of Seal Cartridge Bushing & Seal Assembly.Parts Repaired (← links)
- 05000321/LER-1979-020-03, /03L-1 on 790317:while Working on Tie End Plates, Between Unit 1 & 2 Fuel Pool Transfer Canal,Crack Found. Probably Caused by Impact of Sharp Pointed Object.Plate Will Be Welded Over Crack & Tested (← links)
- 05000321/LER-1979-015 (redirect page) (← links)
- 05000366/LER-1979-002, Forwards LER 79-002/03L-0 (← links)
- 05000366/LER-1979-121-03, /03L-0:on 791117,during Return to Full Power,Max Average Planar Linear Heat Generation Rate of 11.96 Noted. Rapid Increase in Local Thermal Parameters Caused by Burnup of Local Xenon Produced by Rod Withdrawals (← links)
- 05000366/LER-1979-121, Forwards LER 79-121/03L-0 (← links)
- 05000321/LER-1979-091-03, /03L-0:on 791106,insurance Investigation Revealed Required Penetration Seal Not Installed in 2-inch Penetration in Control/Svc Bldg Firewall.Caused by Misinterpreted Drawings.Seal Installed (← links)
- 05000366/LER-1979-045-01, /01T-0 on 790603:following Reactor Scram, HPCI Sys Received Initiation Signal But Failed to Start When Turbine Stop Valve Did Not Open.Caused by Seal Water Line Leaking Water to Bracket Drain Cavity.Line Repaired (← links)
- 05000366/LER-1979-045, Forwards LER 79-045/01T-0 (← links)
- 05000366/LER-1979-043-03, /03L-0 on 790527:while Performing Normal Surveillance Procedure HNP-2-3011 on Pressure Switches 2B21-N020A & B,Switches Tripped at 1,066 & 1,067 Psig. Caused by Setpoint Drift (← links)
- 05000366/LER-1979-043, Forwards LER 79-043/03L-0 (← links)
- 05000366/LER-1979-029, Forwards LER 79-029/03L-1 (← links)
- 05000366/LER-1979-046, Forwards LER 79-046/01T-0 (← links)
- 05000366/LER-1979-032-03, /03T-0 on 790508:during Review of Emergency Load Shed Logic Schemes,Possibility for Unnecessary Trip of Plant Svc Water Pump During LOCA Arose.Logic Schemes to Be Modified (← links)
- 05000366/LER-1979-032, Forwards LER 79-032/03T-0 (← links)
- 05000321/LER-1979-035-03, /03L-0 on 790521:diesel Generator 1A Found Able to Carry Less than 50% of Rated Load.Caused by Improper Alignment of Synchronizer Gear.Gear Realigned (← links)
- 05000321/LER-1979-035, Forwards LER 79-035/03L-0 (← links)
- 05000366/LER-1979-038-01, /01T-0 on 790523:proper Seismic Documentation for RMS Was Absent.Caused by Failure to Document Change.Review of Other Changes Revealed No Problems (← links)
- 05000366/LER-1979-023, Forwards LER 79-023/03L-0 (← links)
- 05000366/LER-1979-017, Forwards LER 79-017/03L-0 (← links)
- 05000366/LER-1979-019-03, /03L-0 on 790201:innerdoor Seal & Shaft Seal Found to Be Leaking.Caused by Crack on Inner Lip of Seal,Which Was Replaced.Shaft Seal Was Dry When Removed.Seal Cleaned, Lubricated & Reinstalled to Satisfaction (← links)
- 05000366/LER-1979-019, Forwards LER 79-019/03L-0 (← links)