Pages that link to "05000318/LER-1979-009, Forwards LER 79-009/03L-0"
Jump to navigation
Jump to search
The following pages link to 05000318/LER-1979-009, Forwards LER 79-009/03L-0:
Displayed 50 items.
- ML19276F391 (redirect page) (← links)
- ML19276F392 (← links)
- 05000318/LER-1979-008, Forwards LER 79-008/03L-0 (← links)
- 05000318/LER-1979-049, Forwards LER 79-049/03L-0 (← links)
- 05000318/LER-1979-049-03, /03L-0:on 791221,during Steady State Operation, Channel B Thermocouple Taken Out of Svc Due to Erratic Indication.Caused by Broken Lead on Current Loop Resistor, Vishay Model S-106C.All Loop Connections Checked Quarterly (← links)
- 05000317/LER-1979-061-01, /01X-0:on 791024,air Start Sys Hangers Failed to Meet Seismic Requirements Per IE Bulletin 79-14. Re-evaluation of Air Line for Seismic Support Requirements Underway (← links)
- 05000318/LER-1979-039-01, /01X-0:on 791024,air Start Sys Hangers Were Not Built to Meet Seismic Requirements.Cause Not Stated.Air Line Is Being re-evaluated Re Support Requirements for Seismic Qualification (← links)
- 05000317/LER-1979-031-01, During Followup Testing on Efs Actuation Sys Undervoltage Logic Circuit A,15-volt Dc Power Supplies to Undervoltage Logic a & B Would Not Respond When Signaled (← links)
- 05000318/LER-1979-008-03, /03L-0 on 790208:22B Safety Injection Tank Level & Pressure Were Below Tech Spec Min Due to Fill Valve Not Shutting Tightly After Being Opened for Drainage.Tank Refilled & Valve Successfully Cycled Several Times (← links)
- 05000318/LER-1979-004-03, /03L-0 on 790127:during Routine Startup of Auxiliary Feedpump,Throttle Valve Would Not Reset.Caused by Disengagement of Traveling Nut Thread During Operation of Valve (← links)
- 05000318/LER-1979-009, Forwards Updated LER 79-009/03L-1 (redirect page) (← links)
- ML20002D924 (redirect page) (← links)
- ML20002D925 (← links)
- ML20002D924 (redirect page) (← links)
- 05000318/LER-1979-009 (redirect page) (← links)
- 05000317/LER-1979-078-01, Has Been Cancelled (← links)
- 05000318/LER-1979-075, Has Been Cancelled (← links)
- 05000317/LER-1979-078, Notifies That LER Number 50-317/79-78 Was Not Used for 1979 (← links)
- 05000317/LER-1979-003-03, /03L-0 on 790218:control Element Assembly 44 Cropped to Bottom of Core & Could Not Be Withdrawn.Reactor Power Reduced to Below 70%.Caused by Loose Connection on Terminal 21 of Coil Power Programmer.Connection Tightened (← links)
- 05000317/LER-1979-028-03, /03L-0 on 790724:while Operating Diesel Generator 11 for Troubleshooting,Smoke Was Noted Coming from Exciter Control Cabinet 1C61C.Caused by Grounded Primary Winding in Exciter Potential Transformer T-54 (← links)
- 05000317/LER-1979-028, Forwards LER 79-028/03L-0 (← links)
- 05000318/LER-1979-047-03, /03L-0:on 791204,while Performing post-refueling Low Power Physics Test,Average Temp Dropped Below Tech Specs.Caused by Operator & Erratic Control of Turbine Bypass Valves (← links)
- 05000318/LER-1979-047, Forwards LER 79-047/03L-0 (← links)
- 05000317/LER-1979-066-03, /03L-0:on 791120,containment Cooler 12 Taken Out of Svc to Repair Sticking Fan Motor Controller Handswitch. Cause Not Stated.Spring Tension on Switch Handle Adjusted (← links)
- 05000317/LER-1979-066, Forwards LER 79-066/03L-0 (← links)
- 05000317/LER-1979-018-04, /04T-0 on 790517:oyster Samples Showed Ag-110m at 88 Plus or Minus 5% Pci/Kg & Decreasing.May Be Caused by Depuration.No Corrective Action Required (← links)
- 05000317/LER-1979-018, Forwards LER 79-018/04T-0 (← links)
- 05000317/LER-1979-016-03, /03L-0 on 790421:one of Eight Main Steam Safety Valves Tested Found Out of Tolerence in Conservative Direction.Caused by Difference in Ambient Conditions Between Time When Valve Last Reset & Time of Test (← links)
- 05000317/LER-1979-016, Forwards LER 79-016/03L-0 (← links)
- 05000317/LER-1979-001, Forwards LER 79-001/01T-0 (← links)
- 05000318/LER-1979-004, Forwards LER 79-004/03L-0 (← links)
- 05000317/LER-1979-007-04, /04T-0 on 790228:sulfuric Acid Was Discharged Onto Ground Via Storm Drains Near Storage Tank.Caused by Pipe Weld Failure.Spill Isolated & Contained,Leak Located & Welded (← links)
- 05000317/LER-1979-007, Forwards LER 79-007/04T-0 (← links)
- 05000317/LER-1979-003, /03L-0 on 790218:azimuthal Power Tilt Exceeded Tech Spec Max.Caused by Dropped Control Element Assembly. Corrective Action Detailed in LER 79-003/03L-0 Unit 1 (← links)
- 05000317/LER-1979-005, Forwards LER 79-005/03L-0 (← links)
- 05000318/LER-1979-007-03, /03L-0 on 790212:snubber 2-83B-2,21 Main Steam Isolation Valve Hydraulic Supply Sys,Inoperable.Caused by Slightly Bent Piston Rod.Snubber Replaced (← links)
- 05000318/LER-1979-007, Forwards LER 79-007/03L-0 (← links)
- 05000318/LER-1979-006-03, /03L-0 on 790204:control Element Assembly Motion Inhibit Failed to Actuate within Tech Spec Limits.Caused by Bad K2 Relay on Relay Card.Relay Replaced & Inhibit Returned to Svc (← links)
- 05000318/LER-1979-006, Forwards LER 79-006/03L-0 (← links)
- 05000317/LER-1979-069-03, /03L-0:on 791127,during Steady State Operation, Diesel Generator 11 Was Removed Form Svc.Caused by Need to Repair Generator Fuel Oil Injector Supply Line.Line Replaced & Diesel Returned to Svc.Leak Marked for Future Ref (← links)
- 05000317/LER-1979-069, Forwards LER 79-069/03L-0 (← links)
- 05000317/LER-1979-027-03, /03L-0 on 790719:metrascope Position of Control Element Assemblies Was Lost.Caused by Faulty Metrascope Power Supply.Faulty Components Replaced,Setpoints Calibr & Alarms Cleared (← links)
- 05000317/LER-1979-027, Forwards LER 79-027/03L-0 (← links)
- 05000318/LER-1979-009-03, /03L-0 on 790226:svc Water Heat Exchanger Saltwater Outlet Throttle Valve 21 Failed to Open on Signal.Cause Unknown.Valve Will Be Repaired During Next Outage (← links)
- 05000318/LER-1979-034-01, /01T-0:on 790914,noted That Air Start Sys Hangers Not Built to Meet Seismic Requirements.Caused by Error Classifying Lines as Nonseismic.Installation of Seismic Pipe Supports Upgraded Diesel Starting Air Sys (← links)
- 05000318/LER-1979-034, Forwards LER 79-034/01T-0 (← links)
- 05000317/LER-1979-015-03, /03L-0 on 790507:low Pressure Safety Injection Pump Stopped for 15 Minutes Due to Spurious Recirculation Actuation Signal.Caused by Voltage Transient.Test Procedures Revised (← links)
- 05000317/LER-1979-015, Forwards LER 79-015/03L-0 (← links)
- 05000318/LER-1979-001-03, /03L-0 on 790106:excessive Reactor Coolant Sys Unidentified Leakage.Caused by Cracked Weld on Socket Weld Downstream of Second Isolation Valve.Study Planned to Propose Design Changes to Correct Fatigue Problem (← links)
- 05000318/LER-1979-001, Forwards LER 79-001/03L-0 (← links)
- 05000318/LER-1979-027-03, /031-0 on 790718:channel C Trips Were Received from Power Level,Thermal margin-low Pressure & Axial Flux Offset.Cause of Intermittent Problem Is Suspected to Be Loose Connection or Faulty Switch Circuit (← links)
- 05000317/LER-1979-025-03, /03L-0 on 790719:reactor Protection Sys Channel a T-cold Input Fluctuated.Cause Suspected to Be Intermittently Open Temp Element or Connection at Element. Repairs Implemented (← links)
- 05000317/LER-1979-025, Forwards LER 79-025/03L-0 (← links)
- 05000318/LER-1979-027, Forwards LER 79-027/03L-0 (← links)