Pages that link to "05000302/LER-1983-014, Forwards LER 83-014/03L-0"
Jump to navigation
Jump to search
The following pages link to 05000302/LER-1983-014, Forwards LER 83-014/03L-0:
Displayed 50 items.
- 05000302/LER-1983-002, Forwards LER 83-002/03L-0 (← links)
- 05000302/LER-1983-013, Forwards LER 83-013/03L-0 (← links)
- ML20069K235 (redirect page) (← links)
- 05000302/LER-1983-014 (redirect page) (← links)
- 05000302/LER-1983-007, Forwards LER 83-007/03L-0 (← links)
- 05000302/LER-1983-008, Forwards LER 83-008/03L-0 (← links)
- 05000302/LER-1983-006, Forwards LER 83-006/03L-0 (← links)
- 05000302/LER-1983-023, Updated LER 83-023/01T-1:on 830613,fire Damper Discovered Missing.Approx 55 Addl Dampers & Chase Connecting Control Complex 108 & 165 Ft Elevations Degraded Due to Incorrect Fire Rating.Caused by Personnel Error (← links)
- 05000302/LER-1983-003, Forwards LER 83-003/03L-0 (← links)
- 05000302/LER-1983-039, Informs That Engineering Investigation of 12 Process Instruments Discovered Out of Calibr During Surveillance Testing & Reported in LER 83-039 Nearing Completion.Next Rept Expected by 840127 (← links)
- 05000302/LER-1983-045, Rev 1 to LER 83-045/03X-1:on 831016,1104 & 08,175-ft Wind Speed Instrumentation & on 831028 & 1102,33-ft Wind Direction Instrumentation Discovered Inoperable.Caused by Severe Weather Damage & Component Failure (← links)
- 05000302/LER-1983-017, Forwards LER 83-017/01T-0.Detailed Event Analysis Encl (← links)
- 05000302/LER-1983-005, Forwards LER 83-005/03L-0 (← links)
- 05000302/LER-1983-031, Supplementary LER 83-031/03L-1:on 830725,containment Isolation Valve CAV-6 & -7 Would Not Close Under Sys Pressure of 1,000 Psi.Caused by Insufficient Design &/Or Inadequate Maint Procedures (← links)
- 05000302/LER-1983-018, Updated LER 83-018/01T-1:on 830413,preliminary Repts Received from B&W Indicated 51 of 120 Upper Core Barrel Bolts W/Ultrasonic Flaw Indications.Caused by Intergranular Stress Corrosion Cracking.Bolts Replaced (← links)
- 05000302/LER-1983-019, Forwards LER 83-019/03L-0 (← links)
- 05000302/LER-1983-011, Forwards LER 83-011/03L-0 (← links)
- 05000302/LER-1983-012, Forwards LER 83-012/03L-0 (← links)
- 05000302/LER-1983-009, Forwards LER 83-009/03L-0 (← links)
- 05000302/LER-1983-016, Forwards LER 83-016/03L-0 (← links)
- 05000302/LER-1983-016-03, /03L-0:on 830323,air Accumulators for Feedwater Valves FWV-39 & FWV-40 Failed to Maintain 27 Psig for 60 Minutes When Isolated from Air Supply.Caused by Water in Instrument Air Sys.Valves Cleaned & O-rings Replaced (← links)
- 05000302/LER-1983-062, :on 831208,reactor Bldg Pressure Recorder Inoperable.Caused by Procedural Inadequacy.Mod to Correct Wiring to Recorder Installed & Surveillance Procedure SP-338 Re Remote Shutdown Panel Revised (← links)
- 05000302/LER-1983-058-03, While Performing Maint on 120-volt Ac Vital Bus Transfer Switch,Fuse Blew,Rendering Inverter 3A Inoperable.Caused by Personnel Inadvertently Shorting Out Lamp Base.Inverter Repaired (← links)
- 05000302/LER-1983-053-03, Safety-related Hydraulic Snubber MSH-252 Declared Inoperable When Lack of Oil Level Indication Noted in Sightglass.Caused by Loose jam-nut on Stationary End of Snubber,Allowing Rotation (← links)
- 05000302/LER-1983-061-03, /03L-0:on 831204,while Performing Control Rod Exercises,Absolute Position Indication for Rod 6,group 2 Failed to Indicate +/- 2% Motion.Caused by Failed Reed Switch.Indicator Tube Will Be Replaced (← links)
- 05000302/LER-1983-003-03, Containment Isolation Valve MUV-41 Declared Inoperable.Caused by Stripped Gear Train Due to Lack of Lubrication.Gears Replaced & Lubricated (← links)
- 05000302/LER-1983-056-03, Discovered Governor on Emergency Feedwater Pump 2 Set Incorrectly.Caused by Setting Inadvertently Changed.Proper Setting Checked on Daily Basis & Locking Cover Installed (← links)
- 05000302/LER-1983-062-03, /03L-0:on 831208,recorder for Reactor Bldg Pressure (BS-65-PR) Determined Inoperable.Caused by Procedural Inadequacy.Revised Drawing Used for Mod Omitted Wire to Recorder.Correction Installed 831227 (← links)
- 05000302/LER-1983-050-03, /03L-0:on 830717,mode Ascension Occurred Prior to Completing Surveillance Testing of LPIS & Engineered Safeguards Components.Caused by Inadequate Procedures. Procedures Revised (← links)
- 05000302/LER-1983-059-03, /03L-0:on 831125,27,1206 & 08,multipoint Recorder for post-accident Monitoring Sys Inoperable.Caused by Inadequate Procedure,Shorted Input Wire,Worn Slip Clutch & Worn Bushing,Respectively (← links)
- 05000302/LER-1983-057-03, /03L-0:on 831122,during Emergency Feedwater Sys Operability Demonstration,Motor Actuator for Turbine Driven Emergency Feedwater Pump Steam Admission Valve ASV-5 Found Inoperable.Caused by Contact Failure (← links)
- 05000302/LER-1983-055-03, /03L-0:on 831118,ESF Actuation Sys Train a Channel RC6 Failed to Ack Low Pressure Injection Bistable Trip. Caused by Mercury Wetted Relay Failing to Operate Properly. Mercury Relay Card Assembly Replaced (← links)
- 05000302/LER-1983-052-03, /03L-0:on 831107,containment Monitoring Isolation Valve WSV-6 Failed Closed.Caused by Blown Fuse Due to Defective Light Bulb.Circuit Reenergized (← links)
- 05000302/LER-1983-054-03, /03L-0:on 831116,while Attaching Identifier Tags on Conduit Connector for Emergency Feedwater Flow Indicator, Cable Connector Pulled Loose.Caused by Personnel Error. Connection Tightened (← links)
- 05000302/LER-1983-051-03, /03L-0:on 831107,emergency Diesel Generator B Tripped.Caused by Worn Insulation on Wire Leading to Selector Switch.Wiring Replaced & Fittings Verified Tight (← links)
- 05000302/LER-1983-049-03, /03L-0:on 831104,audit Revealed Lack of Surveillance Procedure to Examine Sensors During Channel Calibr.Caused by Procedural Inadequacy.Surveillance Procedure SP-161 Revised Prior to Next Calibr (← links)
- 05000302/LER-1983-047-03, /03L-0:on 831021,two Seismic Monitoring Instrumentation Channels Assumed to Have Been Inoperable for at Least 30 Days.Caused by Inadequate Procedure,Allowing Cassettes to Be Used Past Natural end-of-life (← links)
- 05000302/LER-1983-044-01, While Switching from Air Handling Fans AHF-14B & D to AHF-14A & C Due to Low flow,AHF-14A & C Would Not Start.Caused by Failed Damper Solenoid Valve & Metal Fatigue (← links)
- 05000302/LER-1983-045-03, /03L-0:on 831016 & 28,discovered 175 & 33-ft Wind Direction Instrumentation Inoperable,Respectively.Caused by Lightning Damage During Weather Disturbance.Instrumentation Repaired (← links)
- 05000302/LER-1983-046-03, /03L-0:on 831013 & 14,one of Two Reactor Coolant Pump Power Monitor Channels for Reactor Coolant Pumps 1A & 1C,respectively,declared Inoperable.Caused by Sequencing Relay Failure to Change State (← links)
- 05000302/LER-1983-041-03, /03L-0:on 830927,while Performing Quarterly Cycling of Valves,Porv RCV-11 Failed to Close.Caused by Torque Switch Failure.Switch Replaced W/Upgraded Model. RCV-11 Stroked (← links)
- 05000302/LER-1983-040-03, /03L-0:on 830922,during Chemistry Analysis Review, No Documentation Available to Verify Performance of Semiannual Concentration Determination.Caused by Oversight. Chemistry Analyses Will Be Reviewed (← links)
- 05000302/LER-1983-033-03, /03L-0:on 830809,one Containment Air Lock Door Remained Open After Installation of Strongbacks.Caused by Personnel Error.Door Closed.Responsible Personnel Counseled (← links)
- 05000302/LER-1983-017-01, /01T-0:on 830418,during Surface & Visual NDE of Reactor Head & Internals,Lifting Devices Revealed Several Indications on Tripod,Turnbuckle & Latchblock.Caused by Improper Mfg.Indications Repaired (← links)
- 05000302/LER-1983-005-03, /03L-0:on 830125,33-ft Wind Direction Recorder Declared Inoperable.Wind Speed & Direction Failures Possibly Caused by Loose Connector & Wiring Interference.Out of Tolerance Due to Instrument Drift (← links)
- 05000302/LER-1983-063-01, /01T-0:on 831226,while Performing Routine Surveillance,Level Indicators FS-1-LI & FS-2-LI & Sensing Lines for Fire Svc Tanks Found Frozen.Caused by Unusually Cold Weather.Water Added to Tanks (← links)
- 05000302/LER-1983-030-03, During Routine surveillance,once-through Steam Generator a Operating Range Level Recorder Indicated Level Corresponding to 119 Inches, Rendering Recorder Inoperable (← links)
- 05000302/LER-1983-037-03, /03L-0:on 830907,during Performance of Surveillance Procedure SP-340 Re ECCS Pump Operability, DHV-110 Breaker Tripped While Cycling Valve from Open to Closed.Cause Unknown.Breaker Replaced 830922 (← links)
- 05000302/LER-1983-036-01, /01T-0:on 830921,fuel Storage Pool Area Surveys Discovered Not Performed at Least Once Every 24 H from 830915-21.Caused by Personnel Error.Procedures Will Be Revised (← links)
- 05000302/LER-1983-038-01, /01T-0:on 830922,followup Investigation of Quality Audit Finding Uncovered Procedural Inadequacy Allowing Requirement for Surveillance of Certain Fire Barrier Penetration Seals to Be Overlooked (← links)