Pages that link to "05000296/LER-1982-031, Forwards LER 82-031/03L-0"
Jump to navigation
Jump to search
The following pages link to 05000296/LER-1982-031, Forwards LER 82-031/03L-0:
Displayed 50 items.
- 05000259/LER-1982-041, Forwards LER 82-041/03L-0 (← links)
- 05000259/LER-1982-042, Forwards LER 82-042/03L-0 (← links)
- 05000260/LER-1982-019, Forwards LER 82-019/03L-0 (← links)
- 05000260/LER-1982-018, Forwards LER 82-018/03L-0 (← links)
- 05000259/LER-1982-037, Forwards LER 82-037/03L-0 (← links)
- 05000260/LER-1982-029, Forwards LER 82-029/03L-0 (← links)
- 05000259/LER-1982-073, Forwards LER 82-073/03L-0 (← links)
- 05000260/LER-1982-040, Forwards LER 82-040/01T-0 (← links)
- 05000296/LER-1982-061, Forwards LER 82-061/03L-0 (← links)
- 05000296/LER-1982-035, Forwards LER 82-035/03L-0 (← links)
- 05000259/LER-1982-057, Forwards LER 82-057/03L-0 (← links)
- 05000296/LER-1982-034, Forwards LER 82-034/03L-0 (← links)
- 05000259/LER-1982-058, Forwards LER 82-058/03L-0 (← links)
- 05000296/LER-1982-036, Forwards LER 82-036/01T-0 (← links)
- 05000259/LER-1982-050, Forwards LER 82-050/03L-0 (← links)
- 05000259/LER-1982-047, Forwards LER 82-047/03L-0 (← links)
- 05000259/LER-1982-048, Forwards LER 82-048/03L-0 (← links)
- ML20063D092 (redirect page) (← links)
- 05000296/LER-1982-031 (redirect page) (← links)
- 05000260/LER-1982-021, Forwards LER 82-021/03L-0 (← links)
- 05000259/LER-1982-054, Forwards LER 82-054/01T-0 (← links)
- 05000260/LER-1982-025, Forwards LER 82-025/03L-0 (← links)
- 05000296/LER-1982-032, Forwards LER 82-032/03L-0 (← links)
- 05000260/LER-1982-023, Forwards LER 82-023/01T-0 (← links)
- 05000259/LER-1982-044, Forwards LER 82-044/03L-0 (← links)
- 05000259/LER-1982-046, Forwards LER 82-046/03L-0 (← links)
- 05000260/LER-1982-020, Forwards LER 82-020/03L-0 (← links)
- 05000296/LER-1982-030, Forwards LER 82-030/03L-0 (← links)
- 05000259/LER-1982-043, Forwards LER 82-043/03L-0 (← links)
- 05000296/LER-1982-066, Forwards LER 82-066/03L-0 (← links)
- 05000260/LER-1982-038, Forwards LER 82-038/03L-0 (← links)
- 05000259/LER-1982-092, Forwards LER 82-092/03L-0 (← links)
- 05000259/LER-1982-090, Forwards LER 82-090/03L-0 (← links)
- 05000296/LER-1982-041, Forwards LER 82-041/03L-0 (← links)
- 05000260/LER-1982-006, Forwards LER 82-006/03L-0 (← links)
- 05000296/LER-1982-052, Forwards LER 82-052/03L-0 (← links)
- 05000296/LER-1982-050, Forwards LER 82-050/03L-0 (← links)
- 05000259/LER-1982-081, Forwards LER 82-081/03L-0 (← links)
- 05000296/LER-1982-068, Forwards LER 82-068/03L-0 (← links)
- 05000296/LER-1982-067, Forwards LER 82-067/03L-0 (← links)
- 05000260/LER-1982-050, Forwards Updated LER 82-050/03X-1 (← links)
- 05000296/LER-1982-003, Forwards LER 82-003/03L-0 (← links)
- 05000296/LER-1982-027, Forwards LER 82-027/03L-0 (← links)
- 05000259/LER-1982-048-03, /03L-0:on 820718,coil for Relay 16A-K37 Failed, Resulting in Partial Primary Containment Isolation.Caused by Burned Out GE Type CR 120A,Model 5000001G002 Coil.Relay Coil Replaced (← links)
- 05000296/LER-1982-031-03, /03L-0:on 820716,two Degraded Voltage Relay Timers on 4-kV Sdb 3EC & 3ED Found Set at 0.26-s.Caused by Timer Setpoints Change in 820329 Tech Spec Revision,But Not Incorporated Into SI 4.9.A.4.c.Timers Recalibr (← links)
- 05000260/LER-1982-021-03, /03L-0:on 820720,hydrogen Analyzer B Became Inoperable.Caused by Valcor Engineering Corp Solenoid Operator P/N V52630-529-1 Failure.Solenoid Replaced But Failed Again.Valve Will Be Repaired During Refueling Outage (← links)
- 05000259/LER-1982-054-01, /01T-0:on 820804,during Computer Analysis of Branch Lines for Suppression Chamber Attached Piping,Drywell & Torus Purge Sys Found to Have Branch Line Anchored to Floor.Caused by Design Deficiency.Anchor Design Changed (← links)
- 05000259/LER-1982-053-01, /01T-0:on 820730,while Performing Safety Insp 4.7.C.1 Prior to Refueling,Secondary Containment Integrity Could Not Be Confirmed.Caused by Displaced Relief Panel in Steam Tunnel,Allowing Inleakage.Relief Panel Replaced (← links)
- 05000260/LER-1982-025-03, /03L-0:on 820719,during Startup,Relay Coil Failed, Resulting in Partial Primary Containment Isolation.Caused by Burned Out Coil Relay,Causing Relay to Fail in Safe Direction for Primary Containment Isolation (← links)
- 05000260/LER-1982-022-03, /03L-0:on 820721,calculated R Factor Less than R Factor Used to Set Average Power Range Monitor Scram & Rod Block.Caused by High Core Exposure & Reduced Core Reactivity.Tech Spec Changes Issued (← links)