Pages that link to "05000296/LER-1981-070, Forwards LER 81-070/03L-0"
Jump to navigation
Jump to search
The following pages link to 05000296/LER-1981-070, Forwards LER 81-070/03L-0:
Displayed 17 items.
- ML20039F385 (redirect page) (← links)
- 05000296/LER-1981-070-03, /03L-0:on 811211,during Normal Operation, HPCI Suppression Chamber High Level Switches Found 8 Inches Above Normal.Caused by Tech Spec Change Revising Normal Water Levels.Level Switches 73-57A & B Lowered (← links)
- 05000296/LER-1981-070, Forwards LER 81-070/03L-0 (← links)
- 05000259/LER-1981-092-03, /03L-0:on 811218,reactor Water Cleanup Sys Floor Drain High Temp Switch on Units 1 & 2 Did Not Meet Seismic Installation Requirements.Caused by Incorrect Installation of Temp Switch.Switch Repaired (← links)
- 05000259/LER-1981-083, Forwards LER 81-083/03L-0 (← links)
- 05000259/LER-1981-084, Forwards LER 81-084/03L-0 (← links)
- 05000296/LER-1981-070-03, /03L-0:on 811211,during Normal Operation, HPCI Suppression Chamber High Level Switches Found 8 Inches Above Normal.Caused by Tech Spec Change Revising Normal Water Levels.Level Switches 73-57A & B Lowered (← links)
- 05000296/LER-1981-070 (redirect page) (← links)
- 05000259/LER-1981-082-03, /03L-0:on 811125,reactor Core Isolation Cooling Declared Inoperable to Replace Differential Pressure Flow Transmitter.Caused by Fluid Leaking from Instrument Bellows Onto Spanning Resistors.Transmitter Replaced (← links)
- 05000259/LER-1981-082, Forwards LER 81-082/03L-0 (← links)
- 05000259/LER-1981-077-03, /03L-0:on 811127,windspeed Recorder at 33 Ft Indicated Hard Upscale.Caused by Failure of Transistor Q3 on Millivolt to Current Card.Transistor Replaced,Recorder Functionally Tested & Indicator Returned to Svc (← links)
- 05000259/LER-1981-080-03, /03L-0:on 811124,reactor Core Isolation Cooling Sys Failed to Pass Pump Flow Rate Requirements During Operability Tests.Caused by Transmitter Amplifier Card Failure.Gemac 1589K75G702 Amplifier Card Replaced (← links)
- 05000259/LER-1981-080, Forwards LER 81-080/03L-0 (← links)
- 05000259/LER-1981-081, Forwards LER 81-081/03L-0 (← links)
- 05000259/LER-1981-074-03, /03L-0:on 811119,containment Atmosphere Dilution Tank Level Indicator a Found to Be 69% Following Calibr. Caused by Instrument Drift.Tank Filled to Greater than 74%. Recurrence Control Not Required (← links)
- 05000296/LER-1981-069, Forwards LER 81-069/03L-0 (← links)
- 05000260/LER-1981-063, Forwards LER 81-063/03L-0 (← links)
- 05000259/LER-1981-087-03, /03L-0:on 811127,smoke Detector Alarmed & Would Not Clear.Caused by Water in Detector from Unknown Source. Detector Replaced (← links)
- 05000259/LER-1981-069-03, /03L-0:on 811114,gaseous Channel of Continuous Air Monitor O-RM-90-252 Read Downscale During Internal Calibr Check of Counting Ratemeter.Caused by Instrument Drift (← links)