Pages that link to "05000289/LER-1982-010, Forwards LER 82-010/99X-0"
Jump to navigation
Jump to search
The following pages link to 05000289/LER-1982-010, Forwards LER 82-010/99X-0:
Displayed 50 items.
- ML20055B542 (redirect page) (← links)
- 05000289/LER-1982-010 (redirect page) (← links)
- 05000289/LER-1982-009, Forwards LER 82-009/03L-0 (← links)
- 05000289/LER-1982-007, Forwards LER 82-007/03L-0 (← links)
- 05000289/LER-1982-002, Forwards LER 82-002/03L-0 (← links)
- 05000289/LER-1982-013, Forwards LER 82-013/03L-0 (← links)
- 05000289/LER-1982-015, Forwards LER 82-015/03L-0 (← links)
- 05000289/LER-1982-014, Forwards LER 82-014/03L-0 (← links)
- 05000289/LER-1982-016, Forwards LER 82-016/03L-0 (← links)
- 05000320/LER-1982-020, Forwards LER 82-020/01L-0 (← links)
- 05000320/LER-1982-023, Forwards LER 82-023/03L-0 (← links)
- 05000320/LER-1982-022, Forwards LER 82-022/03L-0 (← links)
- 05000320/LER-1982-019, Forwards LER 82-019/03L-0 (← links)
- 05000320/LER-1982-018, Forwards LER 82-018/03L-0 (← links)
- 05000320/LER-1982-017, Forwards LER 82-017/03L-0 (← links)
- 05000320/LER-1982-016, Forwards LER 82-016/03L-0 (← links)
- 05000320/LER-1982-015, Forwards LER 82-015/01L-0 (← links)
- 05000289/LER-1982-016-03, /03L-0:on 821222,during Cold Shutdown,Fire Barrier Penetration Seal 489 Identified as Having Unacceptable Void Under Cable Tray Support Angle.Temporary Damming Matl Installed on Both Sides of Seal (← links)
- 05000289/LER-1982-006-03, /03L-0:on 820427,monitor RM-A9,which Monitors Reactor Bldg Purge Particulate,Iodine & Gaseous Effluents, Valved Out of Svc Due to Improper Valve Line Up.Valve Misalignment Caused by Illegible Valve Position Markings (← links)
- 05000289/LER-1982-008-01, /01T-0:on 820511,oxygen Concentration Exceeded Tech Spec Limit in C Reactor Coolant Bleed Tank After Maint. Caused by Failure to Provide for Maint Activities in Tech Spec.Tech Spec Change Will Clarify App I (← links)
- 05000289/LER-1982-015-03, /03L-0:on 821103,1.5-inch Irregular Diameter Hole Found in Floor Fire Barrier Penetration Seal.Caused by Unsealed Opening.Fire Watch Posted.Seal Repaired on 821109 (← links)
- 05000289/LER-1982-014-03, /03L-0:on 821005,plant Personnel Identified Defective Fire Barrier Penetration Seal.Silicone Foam Seal Matl Separated from Edges of Barrier After Curing.Fire Watch Posted & Fire Barrier Penetration Seal Repaired (← links)
- 05000289/LER-1982-001-01, /01T-1:on 820225,during Shutdown & Evaluation of Control Room Habitability Review Per NUREG-0737,Item III.D.3.4,found That Computer Room Air Conditioning Duct Work Penetrated Wall to Fuel Handling Bldg (← links)
- 05000289/LER-1982-013-03, /03L-0:on 820830,plant Effluent Radiation Monitor (RM-L-7) Had No Sample Flow.Caused by Open Breaker on Sample Pump SR-P-4.Breaker Closed.Operator Surveillance Program Continued to Ensure Proper Flow (← links)
- 05000320/LER-1982-020-01, /01L-0:on 820603,determined That Recent Overflow of Auxiliary Bldg Sump Occurred Due to Influx of Rainwater from Borated Water Storage Tank Recirculation Pump.Caused by Inadequate Flood Protection.Procedures Modified (← links)
- 05000320/LER-1982-023-03, /03L-0:on 820629,air Intake Tunnel (AIT) Halon Sys Actuated Causing Actuation of AIT Deluge Sys & Tripping of Supply & Exhaust Fans in Auxiliary & Fuel Handling Bldgs. Caused by Lightning Actuating Ultraviolet Light Detector (← links)
- 05000289/LER-1982-010-99, /99X-0:on 820526,engineered Safeguards Actuation Sys Failed to Come Out of Bypass During post-maint Testing Following Triac Replacement.Caused by Hampering of New Triac Drop Out Due to Induced Voltage on Input Circuit (← links)
- 05000320/LER-1982-022-03, /03L-0:on 820612,air Intake Tunnel Chlorine Monitor Failed.Caused by Failed Optical Transistor in Monitor.Transistor Replaced & Monitor Returned to Svc (← links)
- 05000320/LER-1982-019-03, /03L-0:on 820601,wind Speed,Wind Direction & Air Temp Indication in Control Room Lost.Caused by Lightning Striking Meteorological Tower Resulting in Blown Amplifier Chips & Fuse.Components Replaced (← links)
- 05000320/LER-1982-018-03, /03L-0:on 820601,air Intake Tunnel Halon Sys Triggered Actuation of Deluge Sys & Tripped Auxiliary & Fuel Handling Bldgs Supply & Exhaust Fans.Caused by Lightning Setting Off Ultraviolet Light Detector.Sys Recharged (← links)
- 05000289/LER-1982-009-03, /03L-0:on 820526,during Shutdown,Improper Valve Lineup Discovered.Caused by Technician Failure to Follow Sampling Procedure & to Realign Valves (← links)
- 05000320/LER-1982-017-03, /03L-0:on 820525,air Intake Tunnel Chlorine Monitor Declared Inoperable During Surveillance Procedure 4303-M10.Caused by Leak in Sample Flowpath at Intake Filter Chlorine Monitor Air Sample Pump.Leak Corrected (← links)
- 05000320/LER-1982-016-03, /03L-0:on 820519,during Testing,Three Hydrogen Purge & 18 Auxiliary Bldg Exhaust Filter Cabinet Deluge Sprinkler Heads Inoperable.Caused by Reduced Flow Rate Capacity Due to Blind Flange in Supply Line & Debris (← links)
- 05000320/LER-1982-015-01, /01L-0:on 820517,w/unit in long-term Cold Shutdown,Incore Thermocouple D14 Exibited Erratic Behavior. Cause Not Determined,Due to Condition of Core Re Incore Instrumentation.Situation Is Being Monitored (← links)
- 05000289/LER-1982-007-03, /03L-0:on 820505,during long-term Shutdown & Reactor Bldg Purge,Iodine Channel of Radiation Monitor RM-A9 Failed Intermittantly.No Cause Discernable.Quarterly Calibr Performed & Recorder Charts Will Be Monitored Each Shift (← links)
- 05000320/LER-1982-014-03, /03L-0:on 820504,auxiliary Bldg Ventilation Exhaust Flow Rate Fluctuated Between 67,000 & 63,000 Cfm, Dropping Below Tech Spec Limit.Cause Unidentified (← links)
- 05000320/LER-1982-014, Forwards LER 82-014/03L-0 (← links)
- 05000289/LER-1982-004, :on 820413,EPRI Tests on Pressurizer Code Safety Valves Revealed Failure to Determine Ability of Valve to Perform Under Feed & Bleed Cooling If Pressurizer Power Operated Relief Valve Isolated.Investigation Underway (← links)
- 05000320/LER-1982-011-01, /01L-0:on 820303,during Problem Analysis of 820108 Event,Apparent Deficiency in Decontamination Factors for Auxiliary Bldg & Fuel Handling Bldg Ventilation HEPA Filters Was Noted.Caused by Lack of Four Plugged Cleanouts (← links)
- 05000320/LER-1982-011, Forwards LER 82-011/01L-0 (← links)
- 05000320/LER-1982-012-03, /03L-0:on 820416,fuel Handling Bldg Exhaust Flowrate Indicated Below Tech Spec Ref Level.Cause Not Determined.Exhaust & Supply Fans Restarted.Investigation Continuing (← links)
- 05000320/LER-1982-012, Forwards LER 82-012/03L-0 (← links)
- 05000289/LER-1982-005-03, /03L-0:on 820411,while in Ordered Shutdown,Liquid Effluent Radiation Monitor Discovered Inoperable.Caused by Failure of Pump SR-P4,due to Piping Clogged W/Mud.Piping Cleared & Motor Replaced (← links)
- 05000289/LER-1982-005, Forwards LER 82-005/03L-0 (← links)
- 05000289/LER-1982-004-01, /01T-0:on 820413,during Shutdown & Tests Conducted Per NUREG-0737,Item II.D.1,EPRI Valve Test Results Indicated Potential Problem W/Pressurizer Code Safety Valves (Dresser Model 31739A).Evaluation Continuing (← links)
- 05000289/LER-1982-003-01, /01T-0:on 820318,while Regenerating B String Cation & Anion Deep Bed Demineralizers,Rinse Cycles Filled Secondary Neutralizing Tank (Snt) Causing Snt to Overflow Caused by Operator Error.Procedures Revised (← links)
- 05000289/LER-1982-003, Forwards LER 82-003/01T-0 (← links)
- 05000320/LER-1982-010-03, /03L-0:on 820222,auxiliary Bldg Vent Sys Supply Fans (AH-E-7A & B) Tripped Resulting in Low Vent Sys Exhaust Flowchart.Caused by Malfunctioning Interlock Relay Between Radiation Monitor & Supply Fans.Relay Replaced (← links)
- 05000320/LER-1982-010, Forwards LER 82-010/03L-0 (← links)
- 05000320/LER-1982-007-03, /03L-0:on 820120,auxiliary Bldg Ventilation Sys Declared Inoperable Due to Low Flow Conditions.Caused by Supply Fan Trip in Fuel Handling Bldg Ventilation Sys on 820120 & 26.Supply Air Flowrate Restored to Operable Status (← links)