Pages that link to "05000285/LER-1979-015, Forwards LER 79-015/01T-0"
Jump to navigation
Jump to search
The following pages link to 05000285/LER-1979-015, Forwards LER 79-015/01T-0:
Displayed 24 items.
- ML20071G669 (redirect page) (← links)
- 05000285/LER-1979-015 (redirect page) (← links)
- 05000285/LER-1979-017, Forwards LER 79-017/03L-0 (← links)
- 05000285/LER-1979-007-01, /01T-3:on 800305,during Review Required by IE Bulletin 79-01,Barksdale Pressure Switch Not Found Environmentally Qualified.Caused by Switch Not Being Properly Specified for Intended Svc.Switch Will Be Upgraded (← links)
- 05000285/LER-1979-004-01, /01T-0 on 790226:during Containment Insp After Outage,Weld Leak Discovered on Controlled bleed-off Line on Reactor Coolant Pump RC-3C.Caused by Vibration Induced Fatigue.Repairs Performed (← links)
- 05000285/LER-1979-004, Forwards LER 79-004/01T-0 (← links)
- 05000285/LER-1979-005-03, /03L-0 on 790226:at 15% Power C Channel Loss of Load Trip Did Not Annunciate.Caused by Bistable Multivibrator Set to 18.1%.Bistable Reset & Surveillance Test Performed (← links)
- 05000285/LER-1979-001, Forwards LER 79-001/01T-0 (← links)
- 05000285/LER-1979-014-01, /01T-0 on 790515:ASCO Solenoid Valves Lacked Sufficient Environ Qualification Data.Caused by Inadequate Specs During Design & Installation Period.Valves Will Be Replaced Following 1980 Refueling Outage (← links)
- 05000285/LER-1979-014, Forwards LER 79-014/01T-0 (← links)
- 05000285/LER-1979-003-03, /03L-1 on 790127:during Containment Pressure Release,Containment Air Monitor Readings Were Abnormally Low.Caused by Closed Isolation Valves.Containment Ventilation Valves Were Closed & Pressure Valves Opened (← links)
- 05000285/LER-1979-003, Forwards LER 79-003/03L-1 (← links)
- 05000285/LER-1979-016-01, /01T-0 on 790517:testing on First Removed Irradiated Surveillance Capsule Showed Higher than Predicted Nil Ductility Transition Temp New Pressure.Temp Limitation Curves Have Been Developed (← links)
- 05000285/LER-1979-016, Forwards LER 79-016/01T-0 (← links)
- 05000285/LER-1979-008-03, /03L-0 on 790321:during Normal Operation,Loop Safety Injection Valve Failed to Open from Lockout Relay Activation.Caused by Dirty Auxiliary Interlock Switch. Switch Cleaned (← links)
- 05000285/LER-1979-008, Forwards LER 79-008/03L-0 (← links)
- 05000285/LER-1979-002-03, /03L-0 on 790117:reactor Protective Sys for Axial Power Distribution Channel a Trip Setpoint Fluctuated Nonconservatively.Caused by Bell & Howell Potentiometer Module Part 384612/001 Failure (← links)
- 05000285/LER-1979-002, Forwards LER 79-002/03L-0 (← links)
- 05000285/LER-1979-020-03, /03L-0:on 791031,during Insps of Accessible Piping,Eight Snubbers on Safety Injection Sys Piping Found Inoperable.Caused by Improper Installation of Anchor Bolts. Base Plate Redesigned & Anchor Bolts Reinstalled (← links)
- 05000285/LER-1979-020, Forwards LER 79-020/03L-0 (← links)
- 05000285/LER-1979-021-21, /21L-0:on 791106,during Insp Required by IE Bulletin 79-14 Re safety-related Piping Sys,Discrepancies Found Between Design Documents & as-built Configuration of Seismic Restraints.Caused by Probable QC Installation Error (← links)
- 05000285/LER-1979-021, Forwards LER 79-021/21L-0 (← links)
- 05000285/LER-1979-018-03, /03L-0 on 790724:steam Generator a Pressure Indicator Ccontroller for C Channel Would Not Reset.Caused by Failure of Sigma Meter Integrally Installed Trip Setpoint.Trip Circuit Replaced & Meter Calibr (← links)
- 05000285/LER-1979-013-03, /03L-0 on 790625:during Normal Operation,Hot Leg Temp Indications C/TI-122H Failed Low.Caused by Power Supply Failure Due to Blown Fuse.Ge/Mac Power Supply Model GR700 Replaced & Sys Returned to Normal (← links)