The following pages link to 05000260/LER-1982-011, Forwards LER 82-011/03L-0:
Displayed 50 items.
- ML20050A989 (redirect page) (← links)
- 05000260/LER-1982-011-03, /03L-0:on 820215,during Operation,While Performing Chamber Water check,2-LI-64-66 Indicated Improper Torus & Level & Declared Inoperable.Caused by Instrument Drift & Possible Air in Ref Leg.Transmitter Calibr (← links)
- 05000260/LER-1982-011, Forwards LER 82-011/03L-0 (← links)
- 05000260/LER-1982-011-03, /03L-0:on 820215,during Operation,While Performing Chamber Water check,2-LI-64-66 Indicated Improper Torus & Level & Declared Inoperable.Caused by Instrument Drift & Possible Air in Ref Leg.Transmitter Calibr (← links)
- 05000260/LER-1982-011 (redirect page) (← links)
- 05000259/LER-1982-016-03, /03L-0:on 820217,during Operation,Reactor Low Water Level Switch 1 (1-LIS-3-203C) Had as-found Calibr of 537.31 Inches.Caused by Instrument Drift.Switch Recalibr & Functionally Tested (← links)
- 05000260/LER-1982-008-03, /03L-0:on 820127,after Calibr,Rod Block Monitor Channel B Failed to Pass Functional Test of SI 4.2.C-2. Caused by Electronic IC Failure Possibly Due to Voltage Spike During Calibr.Ge 136B1333G1 Gain Change Card Replaced (← links)
- 05000260/LER-1982-008, Forwards LER 82-008/03L-0 (← links)
- 05000260/LER-1982-010-03, /03L-0:on 820121,during Full Power Operation SI 4.1.B.2 (APRM Output Signal Calibr) Not Performed within Required Frequency During 811014-28.Caused by Personnel Error (← links)
- 05000259/LER-1982-015-03, /03L-0:on 820209,instrumentation O-XR-90-102-1, O-XR-90-102-2 (620 MSL Windspeed & Direction) & O-XR-90-103 (737 MSL Wind Direction) Failed.Caused by Lightning Striking Environ Data Station.Instrumentation Replaced (← links)
- 05000259/LER-1982-015, Forwards LER 82-015/03L-0 (← links)
- 05000260/LER-1982-010, Forwards LER 82-010/03L-0 (← links)
- 05000259/LER-1982-012-03, /03L-0:on 820125,RHR Pump B & D Min Flow Bypass Valve 1-FCV-74-30 Failed to Close During Surveillance Test. Caused by Failed Coil for Relay 10A-K108B.Coil Replaced (← links)
- 05000259/LER-1982-012, Forwards LER 82-012/03L-0 (← links)
- 05000259/LER-1982-006-03, /03L-0:on 820112,1-PS-3-74B Switch Number 1 Found Operating Below Tech Spec Limit.Caused by Instrument Drift. Barton Model 288 Pressure Switch Recalibr.Action Plan Re Design Change Will Be Forwarded (← links)
- 05000259/LER-1982-006, Forwards LER 82-006/03L-0 (← links)
- 05000260/LER-1982-003-03, /03L-0:on 820116,during Normal Operation,While Performing Surveillance test,PS-3-74A Switch 1 & PS-68-96 Switch 1,low Pressure Switches,Were Out of Tolerance by 4% & 6%.Caused by Instrument Drift.Switches Recalibr (← links)
- 05000260/LER-1982-003, Forwards LER 82-003/03L-0 (← links)
- 05000260/LER-1982-002, Forwards LER 82-002/03L-0 (← links)
- 05000259/LER-1982-009-03, /03L-0:on 820117,during Normal Operation,Smoke Detector in Relay Room Alarmed & Would Not Clear.Caused by Increased Detector Sensitivity Due to Natural Aging.Kidde FT-200 Ionization Smoke Detector Replaced (← links)
- 05000259/LER-1982-009, Forwards LER 82-009/03L-0 (← links)
- 05000259/LER-1982-008-03, /03L-0:on 820116,CAM 1-90-250 (Refuel Floor) Rendered Inoperable Due to Broken Drive Belt.Caused by Normal Wear Due to Continuous Operation.Std V-belt for Schwitzer Model 325 Series Air Pump Replaced (← links)
- 05000259/LER-1982-008, Forwards LER 82-008/03L-0 (← links)
- 05000296/LER-1982-001-03, /03L-0:on 820114,fixed Spray Fire Protection Valve Accidentally Initiated,Causing Smoke Detector to Be Wetted & Emit False Smoke Alarm.Caused by Personnel Hanging Coats on Valve Station.Valve Reset & Smoke Detector Replaced (← links)
- 05000296/LER-1982-001, Forwards LER 82-001/03L-0 (← links)
- 05000259/LER-1982-010-03, /03L-0:on 820112,stack Monitor Was Declared Inoperable After Low Flow Alarm.Caused by 6 Ft Segment of Sample Line Freezing,Inhibiting Sampling Flow to Monitor (← links)
- 05000259/LER-1982-010, Forwards LER 82-010/03L-0 (← links)
- 05000259/LER-1982-005-03, /03L-0:on 820109,1 EN Reactor Motor Operated Valve Board (Lpci)Motor Generator Set Was Removed from Svc Due to Loss of Lubrication on Generator Coupling.Caused by Change of Consistency & Loss of Lubricant.Coupling Repacked (← links)
- 05000260/LER-1982-001, Forwards LER 82-001/01T-0 (← links)
- 05000296/LER-1982-065-03, /03L-0:on 821218,w/diesel Generator 3B Inoperable Due to Battery Testing,Control Power Off Alarm Received for Diesel Generator 3C.Diesel Generator 3C Declared Inoperable & Shutdown Initiated.Caused by Failed Coil in Relay Nv (← links)
- 05000296/LER-1982-063-03, /03L-0:on 821213,during Normal Operation,Turbine & Reactor Zone Exhaust Continuous Air Monitor Became Inoperable.Caused by Blown Fuse.Monitor Out of Svc for 24 H. Fuse Replaced (← links)
- 05000296/LER-1982-063, Forwards LER 82-063/03L-0 (← links)
- 05000296/LER-1982-064, Forwards LER 82-064/03L-0 (← links)
- 05000259/LER-1982-100-03, /03L-0:on 821208,oil Leak Found at Sample Valve Nipple Connection on Recirculation Pump M-G,set 1A,oil Pump.Caused by Failed Thread Sealant on 1/4-inch Threaded Pipe Connection.Nipple & Sample Valve Replaced (← links)
- 05000259/LER-1982-100, Forwards LER 82-100/03L-0 (← links)
- 05000259/LER-1982-094-03, /03L-0:on 821029,smoke Detector X5-39-66XM Alarmed,Potentially Masking Signals from Other Detectors. Caused by Water in Detector.Firewatch Established & Water Removed (← links)
- 05000259/LER-1982-094, Forwards LER 82-094/03L-0 (← links)
- 05000259/LER-1982-082-03, /03L-0:on 821011,continuous Air Monitor 1-90-256 Assumed Downscale Position Due to Miswiring of Alarm Circuit.Caused by Inadequate post-replacement Functional Test After Bell Replacement.Maint Instruction Written (← links)
- 05000259/LER-1982-082, Forwards LER 82-082/03L-0 (← links)
- 05000259/LER-1982-080-03, /03L-0:on 821013,operator Unable to Manually Increase Speed of Diesel Generator D,Rendering Generator Inoperable.Caused by Dirty Contact on GE Mode Switch or Relay Model 12HFA51A42F.Switch Inspected (← links)
- 05000296/LER-1982-048-03, /03L-0:on 821011,following Rod Pattern Adjustment, Calculated R Factor Found Less than R Factor Used to Set Average Power Range Monitor Scram & Rod Block.Caused by Insertion of Pattern Revised Rods (← links)
- 05000259/LER-1982-083-03, /03L-0:on 821013,sample Line Heater Discovered Unplugged,Causing Drywall Continuous Air Monitor to Fail Due to Condensation in Three Detectors.Caused by Personnel Error.Heater Plugged in (← links)
- 05000259/LER-1982-083, Forwards LER 82-083/03L-0 (← links)
- 05000260/LER-1982-031, Forwards LER 82-031/03L-0 (← links)
- 05000259/LER-1982-013, Supplemental LER 82-013/01X-2:on 820202,trip Setpoint on 12 Degraded Voltage Relays on 4-kV Shutdown Boards Found Below Min Trip Point.Caused by Instrument Drift Due to Aging & Variations in Ambient Temp & Supply Voltage (← links)
- 05000259/LER-1982-068-03, Hydrogen Analyzer a Declared Inoperable.Caused by Wire Lifted to 1-FSV-76-57 by Technician.Hydrogen Sample Inlet Pump a Power Relay Contacts Failed.Contacts Replaced & Engineer Reinstructed (← links)
- 05000259/LER-1982-068, Forwards Updated LER 82-068/03X-1 (← links)
- 05000296/LER-1982-046-03, /03L-0:on 820928,while Performing SI 4.9.A.4.b on Diesel Generator 3D,mechanical Remote Speed Control Governor Failed to Function Properly.Caused by Governor Friction Drive Plates Slipping Excessively.New Governor Installed (← links)
- 05000259/LER-1982-079-01, /01T-0:on 821011,during Performance of SI 4.5.A.1.C,test Bypass Valves FCV-75-22 & FCV-75-50 Did Not Meet Required Closing Time.Caused by Variation in Torque Limit Switch Mechanism Settings.Valve Switches Reset (← links)
- 05000259/LER-1982-078, Forwards LER 82-078/01T-0 (← links)
- 05000259/LER-1982-020-03, During Normal Operation, Unidentified Drywell Leakage Increased & Exceeded Limits. Caused by vibration-induced Fatigue Crack in Reactor Water Cleanup Sys Test Connection.Line Rerouted (← links)
- 05000259/LER-1982-063-03, /03L-0:on 820827,reactor Bldg/Turbine Air Lock Doors Opened at Same Time.Caused by Lock Being Out of Adjustment & Not Latching.Differential Air Pressure Caused Door 238 to Open When Door 237 Opened.Lock Repaired (← links)