Pages that link to "05000237/LER-1983-003, Forwards LER 83-003/03L-0"
Jump to navigation
Jump to search
The following pages link to 05000237/LER-1983-003, Forwards LER 83-003/03L-0:
Displayed 50 items.
- ML20028F469 (redirect page) (← links)
- ML20028F470 (← links)
- 05000237/LER-1983-011, Forwards LER 83-011/01T-0 (← links)
- 05000237/LER-1983-004, Forwards LER 83-004/03L-0 (← links)
- 05000237/LER-1983-005, Forwards LER 83-005/03L-0 (← links)
- 05000249/LER-1983-005, Forwards LER 83-005/01T-0 (← links)
- 05000237/LER-1983-012, Forwards LER 83-012/01T-0 (← links)
- 05000237/LER-1983-080, Supplemental LER 83-080/03X-1:on 831124,offgas Log Rad Monitor 2-1705-A Delivered Offgas High Alarm & High Alarm Spiked & Drifted Downscale.Caused by Burned Out Resistor. Power Supply Installed & Monitor Calibr (← links)
- 05000237/LER-1983-023, Forwards LER 83-023/03L-0 (← links)
- 05000249/LER-1983-014, Forwards LER 83-014/03L-0 (← links)
- 05000237/LER-1983-021, Forwards LER 83-021/03L-0 (← links)
- 05000237/LER-1983-017, Forwards LER 83-017/03L-0 (← links)
- 05000237/LER-1983-018, Forwards LER 83-018/01T-0.Detailed Event Analysis Encl (← links)
- 05000237/LER-1983-015, Forwards LER 83-015/03L-0 (← links)
- 05000249/LER-1983-011, Forwards LER 83-011/01T-0 (← links)
- 05000237/LER-1983-016, Forwards LER 83-016/03L-0.Detailed Event Analysis Encl (← links)
- 05000237/LER-1983-014, Forwards LER 83-014/03L-0 (← links)
- 05000237/LER-1983-010, Forwards LER 83-010/03L-0 (← links)
- 05000249/LER-1983-008, Forwards LER 83-008/01T-0 (← links)
- 05000237/LER-1983-002, Forwards Updated LER 83-002/03X-1 (← links)
- 05000249/LER-1983-013, Forwards LER 83-013/03L-0 (← links)
- 05000249/LER-1983-013-03, /03L-0:on 830322,while Performing Main Steam Line High Flow Surveillance,Switch 3-261-21 Tripped Beyond Tech Spec Limit.Caused by Particle on Switch Gear Movement.Switch Cleaned & Retested (← links)
- 05000249/LER-1983-035-03, /03X-1:on 831004,during Drywell Insp,Water Observed Leaking from Recirculation Pump Bowl Drain A. Probably Caused by Socket Weld Joint Bottoming Out.Affected Piping Replaced During Outage (← links)
- 05000249/LER-1983-029-03, /03X-1:on 830726,Reactor Water Level Surveillance Dis 1500-3 & Reactor Water Level Sensor Lits 3-263-73 a Required Initial Dp Loading of 260 Inches of Water to Move Indicator.Caused by Worn Diaphragm Switch (← links)
- 05000237/LER-1983-065-03, /03L-0:on 830917,scram Discharge Vol Vent Valve 2-0399-534 Found Locked Closed Instead of Locked Open.Caused by Valve Left Open During Previous Scram Discharge Vol Test DOS 300-7.All Locked Valves Checked (← links)
- 05000249/LER-1983-035-01, /01T-0:on 831004,during Drywell Insp,Water Observed Leaking from Recirculation Pump Bowl Drain A. Caused by 2-inch Crack on Tee.Affected Piping Will Be Cut Out.Isolation Valves & Tee Will Be Replaced (← links)
- 05000237/LER-1983-068-01, /01T-0:on 831002,during HPCI Surveillance Dis 2300-8,motor Operated Valve 2301-35 Failed to Open on Receiving Open Signal.Caused by Limitorque Valve Operator Terminal 5 Broken Lug Connector.Lug Replaced (← links)
- 05000237/LER-1983-034-03, /03L-0:on 830427,drywell Floor Drain Sump Pumped at Interval Exceeding Tech Spec Limit.Caused by Personnel Failure to Follow Operating Order 26-83 Ensuring Compliance W/Tech Spec Requiring Pumping at 4 H Interval (← links)
- 05000237/LER-1983-001-03, /03L-0:on 830101,cracked Weld Discovered at Feedwater Heater 2D2 Emergency Spill to Normal Drain Line Connector.Caused by Excessive Movement of Drain Line.Weld Will Be Repaired During Upcoming Refueling Outage (← links)
- 05000237/LER-1983-081-03, /03L-0:on 831210,west Side Torus Bulkhead Door Found Open.Caused by Contractor in Area.Operator Immediately Closed & Locked Door,Station Dept Heads Reminded to Inform Personnel & Memo Issued (← links)
- 05000237/LER-1983-076-03, Unidentified Drywell Leakage Calculated to Be 3.08 Gpm.Caused by Cut in Seal Ring Seating on Feedwater Check Valve Body.Cut silver-soldered & New Seal Ring Installed (← links)
- 05000237/LER-1983-078-03, While Preparing to Lower Suppression Pool Level,Valve Lpcj 1501-3A Failed to Open Remotely.Caused by Potentiometer in Valve Control Circuitry Drifting Out of Adjustment.Device Readjusted (← links)
- 05000237/LER-1983-080-03, /03L-0:on 831124,offgas Log Radiation Monitor 2-1705-A Delivered Offgas hi-hi Alarm & Hi Alarm,Spiked & Drifted Downscale.Caused by Offgas Monitor Power Supply Failure.Root Cause Unknown (← links)
- 05000237/LER-1983-156-03, /03L-0:on 831121,LPCI Valve 1501-3A Failed to Open Remotely Upon Starting Component Cooling Svc Water Sys A. Caused by Loosening of Limitorque Operator Thrust Washer Locknut.Washer Adjusted (← links)
- 05000237/LER-1983-154-03, /03L-0:on 831119,unidentified Drywell Leakage Calculated to Be 3.08 Gpm.Caused by Cut in Seal Ring Setting Area on Feedwater Check Valve Body.Cut silver-soldered & New Seal Ring Installed (← links)
- 05000249/LER-1983-041-03, /03L-0:on 831108,while Performing Auto Blowdown Logic Test Dis 250-4,time Delay Relay 287-105A Tripped at 127.6 s, Exceeding Tech Spec Limit.Caused by Instrument Setpoint Drift.Relay Adjusted (← links)
- 05000237/LER-1983-072-03, /03L-0:on 831105,during Reactor Bldg to Torus Vacuum Breaker Surveillance Dis 1600-3,valve 1601-20B Failed to Open.Caused by Failed Versa Solenoid Due to Dirt Contamination.Solenoid Replaced (← links)
- 05000237/LER-1983-079-03, /03L-0:on 831018,while Testing MSIVs 1B & 2B,half Scram Received.Relay 590-102H Found Dropped Out.Caused by Misalignment of Plate Operating Actuating Arm for Limit Switch 1B.Actuating Plate Readjusted (← links)
- 05000249/LER-1983-040-03, /03L-0:on 831028,diesel Generator Did Not Close Onto 4-kV Bus 34-1 & Feed Breaker Remained Tripped.Caused by Dirt Buildup on Contact 52H on Bus.Contact Burnished (← links)
- 05000249/LER-1983-038-03, /03L-0:on 831020,during Refueling Surveillances, HPCI Temp Switches TS3-23371A Tripped at 203.9 F.Caused by Setpoint Drift.Setpoint Adjusted.Repeatability Verified (← links)
- 05000249/LER-1983-039-01, /01T-0:on 831101,during Inservice Insp,Ultrasonic Test Showed Three Rejectable Indications in Weld 8-K46 on Cleanup Line 1201-8 & Three Axial Indications on safe-end to Elbow Weld 28-1 in Recirculation Sys (← links)
- 05000237/LER-1983-070-03, /03L-0:on 831006,24/48-volt 2A Negative Battery Charger Tripped & Declared Inoperable.Caused by Bad Solder Joint & Badly Tarnished Edge Connectors Resulting in Failed Voltage Regulator Board (← links)
- 05000249/LER-1983-037-03, 83-037/03L-0:on 831005,during Daily Battery Surveillance, 250-volt Battery Charger Float Voltage Indicated Improper Float Voltage.Caused by Defective Amplifier Board.Defective Board Replaced (← links)
- 05000249/LER-1983-033-03, /03L-0:on 830926,reactor Bldg Ventilation Inlet Isolation Valve AO 3A-5741 Would Not Close on Auto or Manual Signal.Caused by Accumulated Dirt in Valve Internals. Solenoid Valve & Coil Replaced (← links)
- 05000237/LER-1983-067-03, /03L-0:on 830927,all LPRMs in Levels B & D Bypassed on Front Panel.Rod Block Monitor 8 Placed in Bypass.Caused by Blown Fuse in Power Supply.Fuse Replaced & Monitor 8 Returned to Svc (← links)
- 05000237/LER-1983-069-03, /03L-0:on 831002,during LPCI Sys Valve Operability Test,Pump Suction Valve Mo 2-1501-5C Failed to Close.Caused by Faulty Auxiliary Breaker Contact GE CR 105X in Valve Control Circuitry.Auxiliary Contacts Replaced (← links)
- 05000249/LER-1983-032-03, /03L-0:on 830921,valve LPCI 1501-11B Closed During Installation of Terminal Jumper.Caused by Technician Inadvertently Placing Terminal Jumper on 903-3 Panel Instead of 903-10 Panel (← links)
- 05000249/LER-1983-034-03, /03L-0:on 830923,during Normal Operation,Mobile Crane Hit Wet Pipe Sprinkler Drain Valve,Breaking Valve & Spraying Water on Trackway.Caused by Personnel Error.Valve Repaired.Personnel Counseled (← links)
- 05000237/LER-1983-063-03, /03L-0:on 830830,while Performing MSIV 1090 Closure Test Procedure DOS-250-1,double Indication Occurred on MSIV 2-203-1B When Test Button Released.Caused by Ground on Limit Switch 1B.Circuit Will Be Corrected (← links)
- 05000237/LER-1983-064-03, /03L-0:on 830905,control Rod Drive Scram Discharge Vol Continuous Ultrasonic Test Indication Displayed Erratic Info.Caused by Heating Steam Line Leak Above Monitor Cabinet.Leak Repaired.Module Replaced (← links)
- 05000249/LER-1983-028-03, /03L-0:on 830723,differential Pressure Switch Ps 1349A Actuated Above Tech Spec Limit of 32.0 Inches of Water.Caused by Inadvertent Adjustment of High Differential Pressure Isolation Potentiometer (← links)