Title | Unit 2 Emergency Response Data System (Erds) Modem Failed |
Event Description | `AT 0800 ON 01/27/2006 the Unit 2 ERDS modem failed its testing criteria. The modem will not transmit any of the Unit 2 ERDS data. At 1234, the determination was made that repairs will exceed 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />. The data points transmitted by ERDS are operable. Only the transmission of the Unit 2 data to the NRC is inoperable. Unit 1 ERDS remains operable.
A review of the ability of the Emergency organization to function without ERDS was performed. The NEP (Nuclear Emergency Planning) Duty Planner has established another data line. In response to a Unit 2 event, the affected NERO (Nuclear Emergency Response Organization) positions will verbally transmit the Unit 2 data to the NRC. All affected NERO positions have been notified. Since the Unit 2 ERDS computer system will be unavailable for greater than 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />, this is considered a Loss of Offsite Communications Capability and reportable under 10 CFR 50/72(b)(3)(xiii). The NRC Resident Inspector was notified of this event by the licensee
This is a followup to EN# 42290, which documented a loss of emergency response capability. The Susquehanna computer group replaced the Unit 2 ERDS modem power supply with an identical component then completed the quarterly functional check as of 10:37 on 02/06/2006. As of 10:37 on 02/06/2006, the Unit 2 ERDS modem is operable and will transmit Unit 2 data to the NRC. All affected NERO positions have been notified. The licensee notified the NRC Resident Inspector. R1DO(Gray) has been notified. |
Where | |
---|---|
Susquehanna Pennsylvania (NRC Region 1) | |
Reporting | |
10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness | |
Time - Person (Reporting Time:+1.25 h0.0521 days <br />0.00744 weeks <br />0.00171 months <br />) | |
Opened: | Rich Klinefelter 14:15 Jan 27, 2006 |
NRC Officer: | John Mackinnon |
Last Updated: | Feb 6, 2006 |
42290 - NRC Website
Loading map... {"minzoom":false,"maxzoom":false,"mappingservice":"leaflet","width":"350px","height":"250px","centre":false,"title":"","label":"","icon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"zoom":6,"defzoom":14,"layers":["OpenStreetMap"],"image layers":[],"overlays":[],"resizable":false,"fullscreen":false,"scrollwheelzoom":true,"cluster":false,"clustermaxzoom":20,"clusterzoomonclick":true,"clustermaxradius":80,"clusterspiderfy":true,"geojson":"","clicktarget":"","imageLayers":[],"locations":[{"text":"\u003Cb\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003E\u003Ca class=\"mw-selflink selflink\"\u003EENS 42290\u003C/a\u003E - \u003Ca href=\"/Susquehanna\" title=\"Susquehanna\"\u003ESusquehanna\u003C/a\u003E\n\u003C/p\u003E\u003C/div\u003E\u003C/b\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003EUnit 2 Emergency Response Data System (Erds) Modem Failed\n\u003C/p\u003E\u003C/div\u003E","title":"ENS 42290 - Susquehanna\n","link":"","lat":41.09256666666667,"lon":-76.14176944444445,"icon":"/w/images/c/c7/Talen_Energy_icon.png"}],"imageoverlays":null} | |
Unit 2 | |
---|---|
Reactor critical | Critical |
Scram | No |
Before | Power Operation (100 %) |
After | Power Operation (100 %) |
WEEKMONTHYEARENS 497532014-01-21T18:40:00021 January 2014 18:40:00
[Table view]10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Vent Stack Radiation Monitors Out of Service ENS 482112012-08-20T15:06:00020 August 2012 15:06:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Emergency Response Data System ENS 480202012-06-13T04:00:00013 June 2012 04:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Safety Parameters Display System Out of Service ENS 478202012-04-11T01:48:00011 April 2012 01:48:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Spds and Erds Removed from Service Due to Planned Maintenance ENS 473722011-10-24T21:15:00024 October 2011 21:15:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Emergency Operation Facility Out of Service Due to Planned Maintenance Activity ENS 453362009-09-09T13:30:0009 September 2009 13:30:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Emergency Sirens Out of Service ENS 452802009-08-20T20:43:00020 August 2009 20:43:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Plant Integrated Computer System Resulting in Loss of Erds and Spds ENS 452702009-08-17T16:10:00017 August 2009 16:10:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Emergency Response Data System and Safety Parameter Display System Due to Computer Problems ENS 445132008-09-23T11:30:00023 September 2008 11:30:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Emergency Operating Facility Unavailable ENS 443422008-07-10T19:38:00010 July 2008 19:38:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Emergency Assessment Capabilities Due to Plant Computer Failure ENS 440872008-03-22T14:35:00022 March 2008 14:35:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Spds/Erds Computer System Greater than 8 Hours ENS 440702008-03-17T15:50:00017 March 2008 15:50:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Safety Parameter Display System (Spds) and Emergency Response Data System (Erds) Unavailable Due to Planned Maintenance ENS 432392007-03-15T03:00:00015 March 2007 03:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Outage of Spds and Erds ENS 432282007-03-10T05:30:00010 March 2007 05:30:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Planned Maintenance for Unit 2 Spds and Erds System ENS 424232006-03-15T10:57:00015 March 2006 10:57:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Assessment Capability - Safety Parameter Display System ENS 422902006-01-27T13:00:00027 January 2006 13:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Unit 2 Emergency Response Data System (Erds) Modem Failed ENS 421832005-12-02T05:49:0002 December 2005 05:49:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Safety Parameter Display System (Spds) Failure on Unit Two ENS 420812005-10-26T14:20:00026 October 2005 14:20:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Power at the Emergency Operations Facility ENS 416402005-04-26T11:31:00026 April 2005 11:31:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Spds (Safety Parameter Display System) Is Down for Planned Maintenance ENS 416312005-04-25T02:30:00025 April 2005 02:30:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Spds (Safety Parameter Display System) Is Down for Planned Maintenance ENS 410292004-09-09T08:24:0009 September 2004 08:24:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Emergency Assessment Capability ENS 409562004-08-15T00:45:00015 August 2004 00:45:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Safety Parameter Display System ENS 409482004-08-13T12:00:00013 August 2004 12:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of the Safety Parameter Display System (Spds) for Greater than 8 Hours ENS 405732004-03-07T03:10:0007 March 2004 03:10:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Spds Will Be De-Energized for More than 8 Hours Due to Refueling Outage Activities ENS 401822003-09-19T20:00:00019 September 2003 20:00:00 10 CFR 50.72(b)(3)(xiii), Loss of Emergency Preparedness Loss of Emergency Sirens Due to Storm 2014-01-21T18:40:00 | |