ENS Event | |
---|---|
00:00 Oct 8, 2014 | |
Title | Ultrasonic Testing Reveal Degraded Condition On One Control Rod Drive Mechanism Penetration |
Event Description | In accordance with 10 CFR 50.72(b)(3)(ii)(A), this notification reports a degraded condition on Byron Station Unit 2 that occurred on October 7, 2014, when it was determined that the results of planned ultrasonic testing (UT) examinations performed on one CRDM penetration of the reactor vessel head would not meet the applicable acceptance criteria. Byron Station Unit 2 is presently in day eight of a refueling outage. The examinations were
being performed to meet the requirements of 10 CFR 50.55a(g)(6)(ii)(D) and ASME Code Case N-729-1 to ensure the structural integrity of the reactor vessel head pressure boundary. The UT examinations continue for the remaining CRDM head penetrations. The repairs are currently being planned and will be completed prior to unit start-up. The NRC Resident Inspector has been notified of this condition. |
Where | |
---|---|
Byron Illinois (NRC Region 3) | |
Reporting | |
10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded | |
Time - Person (Reporting Time:+-2.63 h-0.11 days <br />-0.0157 weeks <br />-0.0036 months <br />) | |
Opened: | Charles Berger 21:22 Oct 7, 2014 |
NRC Officer: | Dong Park |
Last Updated: | Oct 7, 2014 |
50517 - NRC Website
Loading map... {"minzoom":false,"maxzoom":false,"mappingservice":"leaflet","width":"350px","height":"250px","centre":false,"title":"","label":"","icon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"zoom":6,"defzoom":14,"layers":["OpenStreetMap"],"image layers":[],"overlays":[],"resizable":false,"fullscreen":false,"scrollwheelzoom":true,"cluster":false,"clustermaxzoom":20,"clusterzoomonclick":true,"clustermaxradius":80,"clusterspiderfy":true,"geojson":"","clicktarget":"","imageLayers":[],"locations":[{"text":"\u003Cb\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003E\u003Ca class=\"mw-selflink selflink\"\u003EENS 50517\u003C/a\u003E - \u003Ca href=\"/Byron\" title=\"Byron\"\u003EByron\u003C/a\u003E\n\u003C/p\u003E\u003C/div\u003E\u003C/b\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003EUltrasonic Testing Reveal Degraded Condition on One Control Rod Drive Mechanism Penetration\n\u003C/p\u003E\u003C/div\u003E","title":"ENS 50517 - Byron\n","link":"","lat":42.07673888888889,"lon":-89.28115,"icon":"/w/images/b/be/Constellation_icon.png"}],"imageoverlays":null} | |
WEEKMONTHYEARENS 573212024-09-13T13:23:00013 September 2024 13:23:00
[Table view]10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Degraded Reactor Vessel Closure Head Penetration ENS 558572022-04-23T13:54:00023 April 2022 13:54:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Ultrasonic Examination Results - Reactor Vessel Head Penetration ENS 525922017-03-05T14:00:0005 March 2017 14:00:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Planned Ultrasonic Test on Previously Repaired Reactor Vessel Penetration Did Not Meet Acceptance Criteria ENS 525912017-03-03T23:05:0003 March 2017 23:05:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Previous Overlay Repair Did Not Meet Acceptance Criteria ENS 514102015-09-19T01:00:00019 September 2015 01:00:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Reactor Vessel Head Penetration Repair Did Not Meet Acceptance Criteria ENS 505172014-10-08T00:00:0008 October 2014 00:00:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Ultrasonic Testing Reveal Degraded Condition on One Control Rod Drive Mechanism Penetration ENS 483112012-09-15T00:00:00015 September 2012 00:00:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Degraded Condition Due to Indications on Reactor Vessel Head During Dye Penetrant Test ENS 466862011-03-19T13:00:00019 March 2011 13:00:00 10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded Ultrasonic Examination Results in Indications on Two Reactor Head Penetrations 2024-09-13T13:23:00 | |