ML17254A975

From kanterella
Revision as of 14:08, 7 July 2018 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Jump to navigation Jump to search
Forwards Rev 0 to Supplementary Rept for Unresolved Issues of Re Ginna Storage Tanks Seismic Qualification, Per SEP Topic III-6
ML17254A975
Person / Time
Site: Ginna 
Issue date: 10/02/1984
From: KOBER R W
ROCHESTER GAS & ELECTRIC CORP.
To: PAULSON W A
Office of Nuclear Reactor Regulation
Shared Package
ML17254A976 List:
References
TASK-03-06, TASK-3-6, TASK-RR NUDOCS 8410110299
Download: ML17254A975 (4)


Text

REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)!ACCESSION NBR;8410110299 ROC.DATE: 84/10/02 NOTARI D: NO DOCKET FACIL:50-244 Robert Emmet Ginna Nuclear Planti Unit ii Rochester G 05000244 AUTH BYNAME AUTHOR AFFILIATION KOBERrR~8~Rochester Gas L Electric Corp, RECIP~NAME RECIPIENT AFFILIATION PAULSONiN~A, Operating Reactors Branch 5

SUBJECT:

Forwards Rev 0 to"Supplementary Rept for Unresolved Issues of RE Ginna Storage Tanks Seismic Qualificationi" per SEP DISTRIBUTION CODE: A028D COPIES RECEIVED:LTR ENCL g SIZE: TITLE: OR Submittal:

SEP Seismic Review NOTES:NRR/DL/SEP 1cy,.OL: 09/19/b9 05000244 REC IP IENT ID CODE/NAME NRR ORB5 BC 01 INTERNAL: ADM/LFMB NRR/DL/SEPB 14 04 COPIES LTTR ENCL 3 3 0 1 1 1 1 RECIPIENT ID CODE/NAME ELD/HDS4 NRR/DL/TAPMG RGN1 COPIES LTTR ENCL EXTERNAI ACRS NRC PDR NOTES: 20 0?e 1 1 1 LPDR NTIS 03 11 TOTAL NUMBER OF COPIES REQUIRED: LTTR 19 ENCL 17 0 1 0 I'I II 1 f t Ct 1$'t It'I~lt<l~t,-tr g'I t.It tt$g Il I~d Wt'll g~N t I g$'I It tl t~t H I It I II ,f, p l(,[II II 0/////I//II

//////////////

I I<~OO I~I////////lllllllllll/

8Z..:: ROCHESTER GAS AND ELECTRIC CORPORATION o 89 EAST AVENUE, ROCHESTER, N.K 14649<001 ROGER W.KOBER vIce pIIesIoeNT elZCTRIC 6 STEAM PROOVCTION TKI epHoNe AAE*cooev14 546-2700 October 2>1984 Director of Nuclear Reactor Regulation Attention:

Mr.Walter A.Paulson>Acting Chief Operating Reactors Branch No.5 U.S.Nuclear Regulatory Commission Washington, D.C.20555

Subject:

SEP Topic III-6g"Seismic Qualification of Tanks" R.E.Ginna Nuclear Power Plant Docket No.50-244

Dear Mr.Paulson:

Enclosed is supplementary information to RGGE's submittal of September 13>1983 concerning SEP Topic III-6<"Seismic Qualification of Tanks".Based on the completed evaluations<

it can be concluded that the Refueling Water Storage Tanke CYCS Holdup Tanks and the Waste Holdup Tank meet the required seismic criteria.Y r truly yours<ui Ro r W.Kober I'41011O>>9 II41O>>.~'I PDR ADOCK 05000244 P"': PDR

'l p'P'I v~~C J)<ll tl I i%