A specific licensee reported a malfunction with one self-shielded irradiator, J.L. Shepherd model Mark I-68A, Serial # 1083 containing two
Cs-137 sources with a total current activity of 6822 Ci. At approximately 2PM [EDT] on 10/26/16 [the licensee performed] an irradiation of 8 mice and were unable to open the sample port. They reported that both visual indicators and survey instruments show the source in the safe, shielded position.
The licensee is in contact with the manufacturer to assist with a repair.
This is a 24-hour reportable incident under N.J.A.C. 7:28-51.1 (10 CFR 30.50(b)2). NJDEP is tracking this incident internally as incident ID# C620765. NMED Report No. is yet to be assigned and will be reported later.
- * * UPDATE ON 12/06/16 AT 1431 EST FROM JAMES MCCULLOUGH TO STEVEN VITTO * * *
The licensee provided a timely update on 11/18/2016 and a final report on 11/30/2016. On November 21, 2016, the device manufacturer replaced a component of the interlock system, a solenoid with spring and lockdown bolt. A preventative maintenance inspection was also performed, confirming the device was restored to normal operation.
NJ Event # NJ-C620765, NMED Item Number: 160448
Notified R1DO (Burritt) and
NMSS Events Resource via email.