Non-Power Reactor Closeout of Generic Letter 2016-01, Monitoring of Neutron Absorbing Materials in Spent Fuel Pools for Aerotest Radiography and Research Reactor, Docket No. 50-228 (CAC No. A11010)
ML17067A273
Person / Time
Site: Aerotest
Issue date: 04/06/2017
From: Alexander Adams
NRC/NRR/DPR/PRLB
To: Warren S
Aerotest
Traiforos S, NRR/DPR/PRLB, 301-415-3965
References
CAC A11010, GL-16-01
Download: ML17067A273 (3)


Text

April 6, 2017

Sandy Warren, General Manager Aerotest Operations, Inc.

3455 Fostoria Way San Ramon, CA 94583

SUBJECT:

AEROTEST OPERATIONS, INC. - NON-POWER REACTOR CLOSEOUT OF GENERIC LETTER 2016-01, "MONITORING OF NEUTRON-ABSORBING MATERIALS IN SPENT FUEL POOLS," FOR AEROTEST RADIOGRAPHY AND RESEARCH REACTOR, DOCKET NO. 50-228 (CAC NO. A11010)

On April 7, 2016, the U.S. Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 2016-01, "Monitoring of Neutron-Absorbing Materials in Spent Fuel Pools" (Agencywide Documents Access and Management System (ADAMS) Accession No. ML16097A169), to address the degradation of neutron-absorbing materials (NAM) in wet storage systems for reactor fuel at power and non-power reactors.

For the non-power reactors, GL 2016-01 requested that licensees provide facility-specific information related to the use of NAM. This information was needed by the NRC staff to verify continued compliance through licensee implementation of effective methods for monitoring of reactor fuel in wet storage so as to detect and mitigate any degradation or deformation of NAM when credited in the facility licensing or design basis for criticality control of fuel in wet storage.

On November 1, 2016, Aerotest Operations, Inc.

submitted a response to GL 2016-01 (ADAMS Accession No. ML16313A158) for Aerotest Radiogr aphy and Research Reactor. The NRC staff conducted a review of your response to GL 2016-01 and determined that your facility does not use NAM in wet fuel storage. Based upon the information you submitted in response to GL 2016-01 and the results of the NRC staff review, the NRC staff has determined that the submission addresses the information requested in GL 2016-01. No further information or action is requested regarding this matter.

Sincerely,

/RA Duane Hardesty Acting For/

Alexander Adams, Jr., Chief Research and Test Reactors Licensing Branch

Division of Policy and Rulemaking Office of Nuclear Reactor Regulation cc: See next page Aerotest Operations, Inc. Docket No. 50-228

cc: California Energy Commission

1516 Ninth Street, MS-34

Sacramento, CA 95814

Radiologic Health Branch P.O. Box 997414, MS 7610 Sacramento, CA 95899-7414

Test, Research and Training

Reactor Newsletter P.O. Box 118300 University of Florida

Gainesville, FL 32611

Jay E. Silberg Pillsbury Winthrop Shaw Pittman LLP 1200 Seventeenth Street, NW Washington, DC 20036-3006

Anthony Nellis President, Aerotest Operations, Inc. Vice President, Legal Americas, Autoliv ASP, Inc. 1320 Pacific Drive

Auburn Hills, MI 48326

ML17067A273; *concurred via email OFFICE NRR/DPR/PRLB/PM NRR/DPR/PROB/LA*NRR/DPR/PGCB/BC NRR/DPR/PRLB/BCNAME STraiforos NParker SStuchell AAdams (DHardesty for) DATE 4/5/17 4/5/17 4/6/17 4/6/17