The following is a summary of information provided by the
Arkansas Department of Health, Radiation Control Section (ADH) via email:
On August 5, 2025, at 0933 CDT, the ADH was contacted by the licensee's assistant radiation safety officer to report that during quarterly shutter checks, they observed that a fixed gauge shutter was difficult to open. Subsequently, while attempting to operate it manually, it became damaged with broken bolts. The licensee contacted the manufacturer to initiate a repair or replacement. The manufacturer is recommending replacement.
All necessary safety precautions were taken during the inspection and operation attempt to prevent any further damage or risk. The source is still in service and is being used for continuous level reading. There were no unnecessary exposures.
Device Information:
Manufacturer: VEGA
Source Housing Model: SH-F1A
Source Housing Serial: 1694CP
Activity: 5 mCi
Isotope: Cs-137
Arkansas Event Number: ARK-2025-009