Notice of Violation from Insp on 810126-28
ML20003D038
Person / Time
Site: University of Michigan
Issue date: 02/10/1981
From: Heishman R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML20003D037 List:
References
50-002-81-01, 50-2-81-1, NUDOCS 8103181113
Download: ML20003D038 (1)


Text

6 APPENDIY A NOTICE OF VIOLATION University of Michigan Docket No.50-002 As a result of the inspection conducted on January 26-28, 1981, and in accordance with the Interim Enforcement Policy, 45 FR 66754 (October 7, 1980) the following violation was identified.

Technical Specification 4.4.a states that the primary coolant pH shall be measured weekly. Operating Procedure Number 301 (OP-301) states that pH is to be measured with a pH meter. Technical Specification 4.4.b states that the primary coolant resistivity shall be measured weekly.

Contrary to the above, the primary coolant pH was not measured with a pH meter during the weeks of December 21 and December 28, 1980 and primary coolant resistivity was not measured during the week of December 28, 1980.

.This is a Severity Level VI violation (Supplement I).

(50-002/81-01-01)

This notice is sent to you pursuant to the provisions of Section 2.201 of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations.

oj

__ L_

AL *'

' Februa y '10, 1931 Dated R. F. Heishman, Chief Reactor Operations and Nuclear Support Branch' I