TXX-4244, Interim Significant Deficiency Rept SDAR-129 Re Error in Tolerances Used in Calibr of Adhesion Tester.Evaluation Continuing.Completion Anticipated by 840901

From kanterella
Revision as of 10:43, 13 December 2024 by StriderTol (talk | contribs) (StriderTol Bot change)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Interim Significant Deficiency Rept SDAR-129 Re Error in Tolerances Used in Calibr of Adhesion Tester.Evaluation Continuing.Completion Anticipated by 840901
ML20094D955
Person / Time
Site: Comanche Peak  
Issue date: 07/31/1984
From: Clements B
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To: Johnson E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
SDAR-129, TXX-4244, NUDOCS 8408090044
Download: ML20094D955 (1)


Text

TEXAS UTILITIES GENERATING COMPANY M K Y WAY THW E H

  • 4 00 NilHill E ll.I VE MTH EET, I,.II. M t
  • IDAl.I.AM. TEX A M 7 3 201 e.u ".'.SJ "ffs"L.

July 31, 1984 TXX-4244 JU me 2s84

. j Mr. E.H. Johnson, Chief Reactor Project Branch 1 u

U.S. Nuclear Regulatory Commission t

Office of Inspection & Enforcenent 611 Ryan Plaza Drive, Suite 1000 Docket Nos.:

50-445 Arlington, TX 76012 50-446 COMANCHE PEAK STEAM ELECTRIC STATION PROTECTIVE C0ATINGS ADHESION TESTER QA FILE: CP-84-05, SDAR-129 FILE N0.:

10110

Dear Mr. Johnson,

On January 16, 1984 we verbally contacted your Mr. R.G. Taylor of a deficiency regarding an error in the tolerances used in the calibration of the adhesion tester. We have submitted interim reports logged TXX-4111 and TXX-4168, dated February 15, 1984 and May 11, 1984.

We are continuing our evaluation and anticipate conpletion by September 1, 1984.

Very truly yours, Billy R. Clements BRC:tlg cc:

NRC Region IV - (0 + 1 copy)

Director, Inspection & Enforcemerit (15 copies)

U.S. Nuclear Regulatory Commission Washington, DC 20555 8408090044 840731 M

PDR ADOCK 05000445 gI a unsrunsox or ruxan s,ss.uruun us.ucruse vous asv L