ENS 47724
From kanterella
Revision as of 21:04, 1 March 2018 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
ENS Event | |
---|---|
18:15 Mar 7, 2012 | |
Title | Local Alarm Horn Was Found to Be Inaudible During Routine Testing |
Event Description | At approximately 1315 EST on 3/7/12, it was discovered during routine testing on an outdoor Criticality Accident Alarm System (CAAS) Data Acquisition Module (DAM #21), that the local alarm horn in the Wilmington Field Services Center (WFSC) building #1 in-vessel tooling refurbishment area was inaudible. The cause of the condition is under investigation.
Personnel were removed from the in-vessel tooling refurbishment area until compensatory measures were established. There are not active fissile material operations impacted by this discovery, thus no unsafe condition existed. The licensee notified the NC Division of Radiation Protection and New Hanover County. |
Where | |
---|---|
Global Nuclear Fuel - Americas Wilmington, North Carolina (NRC Region 2) | |
License number: | Snm-1097 |
Reporting | |
10 CFR 70.50(b)(2) | |
Time - Person (Reporting Time:+16.78 h0.699 days <br />0.0999 weeks <br />0.023 months <br />) | |
Opened: | Scott Murray 11:02 Mar 8, 2012 |
NRC Officer: | Charles Teal |
Last Updated: | Mar 8, 2012 |
47724 - NRC Website
Loading map... {"minzoom":false,"maxzoom":false,"mappingservice":"leaflet","width":"350px","height":"250px","centre":false,"title":"","label":"","icon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"zoom":6,"defzoom":14,"layers":["OpenStreetMap"],"image layers":[],"overlays":[],"resizable":false,"fullscreen":false,"scrollwheelzoom":true,"cluster":false,"clustermaxzoom":20,"clusterzoomonclick":true,"clustermaxradius":80,"clusterspiderfy":true,"geojson":"","clicktarget":"","imageLayers":[],"locations":[{"text":"\u003Cb\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003E\u003Ca class=\"mw-selflink selflink\"\u003EENS 47724\u003C/a\u003E - \u003Ca href=\"/Global_Nuclear_Fuel\" title=\"Global Nuclear Fuel\"\u003EGlobal Nuclear Fuel\u003C/a\u003E\n\u003C/p\u003E\u003C/div\u003E\u003C/b\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003ELocal Alarm Horn Was Found to Be Inaudible During Routine Testing\n\u003C/p\u003E\u003C/div\u003E","title":"ENS 47724 - Global Nuclear Fuel\n","link":"","lat":34.320930555555556,"lon":-77.92285,"icon":""}],"imageoverlays":null} | |
Global Nuclear Fuel with 10 CFR 70.50(b)(2) | |
WEEKMONTHYEARENS 497592014-01-22T18:15:00022 January 2014 18:15:00
[Table view]10 CFR 70.50(b)(2) Inoperable Criticality Warning System Local Alarm in Wilmington Field Services Center Building Number 1 ENS 481002012-07-11T21:40:00011 July 2012 21:40:00 10 CFR 70.50(b)(2) Criticality Horns Rendered Inoperable Due to Lightning Strike ENS 478512012-04-18T17:45:00018 April 2012 17:45:00 10 CFR 70.50(b)(2) Local Alarm Horn Was Found to Be Inaudible During Routine Testing ENS 477242012-03-07T18:15:0007 March 2012 18:15:00 10 CFR 70.50(b)(2) Local Alarm Horn Was Found to Be Inaudible During Routine Testing ENS 472202011-08-29T17:00:00029 August 2011 17:00:00 10 CFR 70.50(b)(2) Criticality Accident Alarm System Horn Discovered Inoperable ENS 470612011-07-14T20:55:00014 July 2011 20:55:00 10 CFR 70.50(b)(2) Inoperable Criticality Accident Alarm System Warning Horns ENS 470472011-07-12T21:30:00012 July 2011 21:30:00 10 CFR 70.50(b)(2) Inaudible Criticality Warning Siren ENS 470662011-05-01T16:00:0001 May 2011 16:00:00 10 CFR 70.50(b)(2) Previous Inoperability of Criticality Accident Alarm System Warning Circuit Not Identified ENS 447242008-12-16T11:00:00016 December 2008 11:00:00 10 CFR 70.50(b)(2) Criticality Warning System Disabled ENS 432672007-03-30T11:40:00030 March 2007 11:40:00 10 CFR 70.50(b)(2) Criticality Warning System Alarm Actuation Due to Power Fluctuation ENS 429792006-11-09T10:00:0009 November 2006 10:00:00 10 CFR 70.50(b)(2) Failure of Warning Horns ENS 427472006-08-01T09:00:0001 August 2006 09:00:00 10 CFR 70.50(b)(2) Audible Horn System Malfunction ENS 406332004-04-01T18:00:0001 April 2004 18:00:00 10 CFR 70.50(b)(2) Outdoor Area Criticality Warning System Horn Inoperative 2014-01-22T18:15:00 | |