TXX-4664, Interim Deficiency Rept CP-85-51 Re Improper Application of Low Sulphur Content A588 Steel Used in Pipe Whip & Moment Restraint Fabrication.Initially Reported on 851205

From kanterella
Revision as of 01:18, 12 December 2024 by StriderTol (talk | contribs) (StriderTol Bot change)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Interim Deficiency Rept CP-85-51 Re Improper Application of Low Sulphur Content A588 Steel Used in Pipe Whip & Moment Restraint Fabrication.Initially Reported on 851205
ML20137B456
Person / Time
Site: Comanche Peak  
Issue date: 01/06/1986
From: Beck J, Counsil W
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To: Johnson E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
CP-85-51, TXX-4664, NUDOCS 8601150351
Download: ML20137B456 (1)


Text

7 Log i TXX-4664 TEXAS UTILITIES GENERATING COMPANY F11e # 10110 BETWAYTOWER.400 7003T,5 (DEJ1/3 WTERET.1.3. 5 8. IB AllAB. TRE AA 78908 January 6, 1986

%y@ggg g E3*E&?2Y.?Ah q

Mr. Eric H. Johnson, Acting Director y

hg

~

Division of Reactor Safety and Projects U.S. Nuclear Regulatory Commission 611 Ryan Plaza Dr., Suite 1000 t

~"

Arlington, TX 76012

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)

DOCKET N05. 50-445 AND 50-446 APPLICATION OF LOW SULPHUR CONTENT A588 STEEL SDAR:

CP-85-51

Dear Mr. Johnson:

On December 6, 1985, we verbally notified your Mr. S. Phillips of a defi-ciency regarding the improper segregation, control and application of low sulphur content A588 steel used in the fabrication of pipe whip and moment restraints. Review by Gibbs & Hill has indentified three structures in which the use of the improper A588 steel could have detrimental effects.

Nondestructive testing is planned the week of January 6, 1986 to provide additional information required to conclude the evaluation.

We are continuing our evaluation and anticipate completion by February 5, 1986.

Very truly yours, v.s. c 4 W. G. Counsil l

By:

T.'.

Beck Vice President JCH/ arm c - NRC Region IV (0+1 copy)

Director, Inspection & Enforcement (15 copies)

U.S. Nuclear Regulatory Commission j

Washington, D.C.

20555 8601150351 106 PDR ADOCK 0 45 4

t

/

o

,p 9w

-. - - -...-.- - -