ML21291A182
Jump to navigation
Jump to search
ML21291A182 | |
Person / Time | |
---|---|
Issue date: | 10/20/2021 |
From: | Lingham S NRC/NRR/DORL/LPL4 |
To: | |
Lingham S | |
Shared Package | |
ML21291A179 | List: |
References | |
EPID: L-2021-NFO-0007 | |
Download: ML21291A182 (1) | |
Text
Does Al HEAF Require a Change to Modeled ZOI?
It is a safety concern warranting action It is not a safety concern
- OECD non-prototypic test but no ZOI
- Cables very robust measured
- 100,000s of component operating years with Al widespread
- No op ex shows an increased ZOI
- Harris HEAF with Al
- Actual ZOI bounded by modeled ZOI
- Cables in ZOI functional
- Robinson within modeled ZOI
- Appendix R separation - change in ZOI would have to be ve r y l a rge