From:GregFulford<Greg.Fulford@nordion.com>
Sent:Friday,May31,202412:55PM
To:EarlLove<Earl.Love@nrc.gov>
Cc:ErinColeman<Erin.Coleman@nordion.com>;RichardWassenaar<Richard.Wassenaar@nordion.com>
Subject:
[External_Sender]UpdatetoNordion'sQAProgram
HelloEarl,
Thankyouforyourques ons.Toclarifyourproposalwithrespecttoaudi ngourQAProgramforTransport,Io erthe
followingexplana on.Pleaseletmeknowhowyoufeelaboutthis.
Thereare13QualityElementsthatapplytoNordionsQAProgramasprovidedtotheNRC.Noteourlimitedscopedoes
notincludeDesignnorSpecialProcesses.Thequalityelementsiden edinIN/QA2697Z000addressspeci c
compliancewith10CFR71SubpartH.ThereferencedprocedureswithinthatqualityplanarepartofNordionsoverall
qualityprogram.Someofthesearespeci ctoourtransportprogram,whereasothersapplyacrossallac vi esat
Nordion.
Afurthercomplexitysurroundsourtransportprogram.Givenourloca oninCanada,wearesubjecttobothCNSCand
NRCregulatoryrequirementsformanagementsystems.Toaddressthis,wehaveelectedtodocumenttwoconnected
butdis ncttransporta onmanagementsystems;ourgeneraloverallprogramasde nedinIN/QA0224Z000whichis
submi edtotheCNSCaspartoftheirtransportcer ca onprocessandaU.S.focusedprogramasdetailedinIN/QA
2697Z000thatisintendedtospeakto10CFRPart71SubpartHrequirements.
Speci ctoaudi ngtheelementsinIN/QA2697Z000,ourproposalistoassesscomplianceofthefollowingelements
(speci ctotransport)onanannualbasis:
ControlofPurchasedMaterial,EquipmentandServices IdentificationandControlofMaterials,PartsandComponents InternalInspection ControlofMeasurementandTestEquipment Handling,StorageandShippingControl Inspection,TestandOperatingStatus Non-conforming Materials, Parts or Components Corrective Action
Wenotethatinexecu ngourcommitmentstotheabovequalityelements,wewillgeneraterecordsandac onsthat
aredirectlyauditable.OurannualauditofIN/QA2697Z000willfocusonUSbasedtransportac vi es.
Weproposetoauditthesystema celementslistedbeloweverythreeyears:
x DocumentControl x QualityAssuranceRecords x Audits Ourra onalebehindthe3yearcyclefortheseelementsisthatthesearewellestablished,sta cprogramsat
Nordion.Wefollowanelectronicqualitymanagementprogramthatensuresallprocedures,documenta onand
drawingsarecontrolledandapprovedaccordingtoapredesignatedstructure.Thissystemalongwithourchange
controlprogramandrecordreten onprocedurede neshowwemeettheelementsofDocumentControlandQA
Records.Similarlyourinternalauditprogramsarewellestablishedandde ned.Inaccordancewithourotherquality
systems(ISO9001,ISO/IEC17025andCSAN299.2)wecurrentlyperformanauditofourinternalauditprogramevery3
years.Wefeelthatassessingthesethreeelementsonatriennialbasisfallswithinagradedapproachtothe
program.Webelievethatthisauditfrequencydoesnotprovideanyaddi onalrisktothesystem.
1 Addi onally,IwouldaddthatNordionissubjecttoanannualexternalauditaspartofourISO9001cer ca on.BSI
Group,anaccreditedthirdparty,willauditNordionsQualityManagementSystems/QMSInfrastructure(Audits,
complaints,NCMRs,customerfeedback,ManagementReview,CAPAs,andperformancemetrics))eachyear.
Ifyouhavefurtherques onsorwouldliketodiscusspleasedonthesitatetoreachouttome.
Regards,
GregFulford
ManagerRadiationProtectionandNuclearTransportation
Nordion
447MarchRd.
Ottawa,Ont.K2K1X8
6135923400x2658
2