ENS 57162
From kanterella
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
ENS Event | |
---|---|
23:13 Jun 5, 2024 | |
Title | Concurrent Report for Degraded Hepa Filter |
Event Description | The following information was provided by the licensee via phone and email:
This concurrent report is being made because a HEPA filter on a scrap recovery line had degraded below the efficiency that would allow it to remain in service (76.85 percent versus 99.95 percent). This condition is reportable to the Washington Department of Health in accordance with Radioactive Air Emissions License (RAEL) 038. The scrap recovery line has been shut down pending further investigation into the cause of the loss of filter efficiency. Investigation has revealed that no limits were exceeded and no additional reporting is required. |
Where | |
---|---|
Framatome Anp Richland Richland, Washington (NRC Region 2) | |
License number: | SNM-1227 |
Reporting | |
Part 70 App A (C) | |
Time - Person (Reporting Time:+-7.12 h-0.297 days <br />-0.0424 weeks <br />-0.00975 months <br />) | |
Opened: | Brandon Hanson 16:06 Jun 5, 2024 |
NRC Officer: | Kerby Scales |
Last Updated: | Jun 5, 2024 |
57162 - NRC Website
Loading map... {"minzoom":false,"maxzoom":false,"mappingservice":"leaflet","width":"350px","height":"250px","centre":false,"title":"","label":"","icon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"zoom":6,"defzoom":14,"layers":["OpenStreetMap"],"image layers":[],"overlays":[],"resizable":false,"fullscreen":false,"scrollwheelzoom":true,"cluster":false,"clustermaxzoom":20,"clusterzoomonclick":true,"clustermaxradius":80,"clusterspiderfy":true,"geojson":"","clicktarget":"","imageLayers":[],"locations":[{"text":"\u003Cb\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003E\u003Ca class=\"mw-selflink selflink\"\u003EENS 57162\u003C/a\u003E - \u003Ca href=\"/Framatome_ANP_Richland\" title=\"Framatome ANP Richland\"\u003EFramatome ANP Richland\u003C/a\u003E\n\u003C/p\u003E\u003C/div\u003E\u003C/b\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003EConcurrent Report for Degraded Hepa Filter\n\u003C/p\u003E\u003C/div\u003E","title":"ENS 57162 - Framatome ANP Richland\n","link":"","lat":46.35016666666667,"lon":-119.302,"icon":""}],"imageoverlays":null} | |
Framatome ANP Richland with Part 70 App A (C) | |
WEEKMONTHYEARENS 571622024-06-05T23:13:0005 June 2024 23:13:00
[Table view]Part 70 App A (C) Concurrent Report for Degraded Hepa Filter ENS 571162024-05-07T17:15:0007 May 2024 17:15:00 Part 70 App A (C) Concurrent Report for Offsite Notification ENS 569042023-12-17T17:45:00017 December 2023 17:45:00 Part 70 App A (C) Concurrent Report for LOW Filter Efficiency ENS 568512023-11-02T18:45:0002 November 2023 18:45:00 Part 70 App A (C) Concurrent Report for Degraded Connector ENS 562922023-01-02T20:20:0002 January 2023 20:20:00 Part 70 App A (C) Concurrent Report for Onsite Injury ENS 561732022-09-22T18:30:00022 September 2022 18:30:00 Part 70 App A (C) Concurrent Report for Shipment of Undeclared Hazardous Waste ENS 556862022-01-04T00:15:0004 January 2022 00:15:00 Part 70 App A (C) Offsite Notification ENS 556662021-12-20T17:20:00020 December 2021 17:20:00 Agreement State, Part 70 App A (C) Offsite Notification ENS 554152021-08-17T18:00:00017 August 2021 18:00:00 Part 70 App A (C) Concurrent Report for Offsite Notification ENS 549622020-10-20T18:45:00020 October 2020 18:45:00 Part 70 App A (C) Concurrent Report Due to Non-Radiation Worker Injury ENS 420172005-09-26T20:00:00026 September 2005 20:00:00 Part 70 App A (C) Offsite Notification 2024-06-05T23:13:00 | |