Northem States Power Company 414 Nicollet Mall Minneapohs Minnesota 55401-1927 Telephone (612) 330-5500 September 2, 1993 US Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555 Prairie Island Nuclear Generating Plant Docket Nos. 50-282 License Nos. DPR-40 50-306 DPR-52 l

Submittal of NSPNAD-93003-A Your Safety Evaluation Report (SER) dated July 16, 1993 approved our Topical NSPNAD-93003 titled, " Transient Power Distribution Methodology." We have re-issued this topical with your SER placed in the front of the document (printed on blue paper) and are submitting this for your information.

Your SER stated on page 3:

The generic case list presented in Table X.A and Figure X.G represents the limiting cases necessary for qualification of the generic curve.

This statement was discussed with Marsha Gamberoni (PI NRC Project Manager) and Larry Kopp (SER author) on August 19, 1993. The following clarification summarizes our discussion:

The generic case list presented in Table X.A and Figure X.G represents the limit cases necessary for qualification of the generic curve discussed in the topical. If different initial conditions (e.g. AI range, target axial offsets, exposure points, etc.) are used to develop a different generic curve, a conservative case list will be developed.

This case list may need be different from the case list presented in the topical.

Please contact Tom Parker at 612-337-2030, if you require additional information. This letter contains no new NRC commitments.

f R<! h e ;pe g er 0 Anderson Director Licensing and Management Issues c: Regional Administrator-III, NRC(w/o copy)

NRR Project Manager, NRC Resident Inspector, NRC (w/o copy)

State of Minnesota (w/o copy)

Attn: Kris Sanda J Silberg (w/o copy)