TXX-4915, Interim Part 21 & Deficiency Rept CP-86-47 Re Generic Design Concern W/Qualification of Fire Barrier Seals Supplied by Bisco.Initially Reported on 860616.Evaluation Continuing. Next Rept Will Be Submitted by 860829

From kanterella
Revision as of 00:42, 10 July 2023 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Interim Part 21 & Deficiency Rept CP-86-47 Re Generic Design Concern W/Qualification of Fire Barrier Seals Supplied by Bisco.Initially Reported on 860616.Evaluation Continuing. Next Rept Will Be Submitted by 860829
ML20207K951
Person / Time
Site: Comanche Peak  
Issue date: 07/16/1986
From: Counsil W, Keeley G
TEXAS UTILITIES ELECTRIC CO. (TU ELECTRIC)
To: Johnson E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
REF-PT21-86-348-000 CP-86-47, PT21-86-348, PT21-86-348-000, TXX-4915, NUDOCS 8607300142
Download: ML20207K951 (1)


Text

Log # TXX-4915 File # 10110 909.5 TEXAS UTILITIES GENERATING COMPANY MKYWAY TOWER . 400 NORTH OIJVE NTREET. L.BB. 51. DALLAN, TEXAN 75208 g July 16, 1986

~

eME7Af?JA*A g g [ {p g 3 "

s[  :

i  !

JUL 2 i G86 Mr. Eric H. Johnson, Director Division of Reactor Safety and Projects

, Ib U. S. Nuclear Regulatory Commission 011 Ryan Plaza Drive, Suite 1000

Arlington, TX 76012 l

SUBJECT:

COMANCHE PEAK STEAM ELECTRIC STATION (CPSES)

DOCKET NOS. 50-445 AND 50-446 FIRE PROTECTION SEAL DESIGN SDAR: CP-86-47 (INTERIM REPORT)

Dear Mr. Johnson:

On June 16, 1986, we verbally notified your Mr. C.- Hale of a deficiency involving a generic design concern with the qualification of fire barrier seals supplied by BISCO. This is an interim report of a potentially reportable item under the provisions of 10CFR50.55(e).

We are continuing our evaluation and anticipate submitting our next report by August 29, 1986.

Very truly yours, hY (k h b W. G. Co s'l '

l f

By: [

G. S. Keeley Manager,-Nucleg/ Li censing I JCH/arh c - NRC Region IV (0 + 1 Copy) j Director, Inspection & Enforcement (15 copies) l U. S. Nuclear Regulatory Commission l Washington, D.C. 20555 gf3$$

I a var,,w., or r-n un,- -cn,c c~a-r

\g

! $f . [  ?