Determining the Zone of Influence for High Energy Arcing Faults using Fire Dynamics Simulator - Comment Resolution The NRCs Office of Nuclear Regulatory Research published draft research information letter entitled Determining the Zone of Influence for High Energy Arcing Faults Using Fire Dynamics Simulator on May 13th, 2022. Public comments were solicited via notice in the Federal Register (87 FR 29395, Docket Number NRC-2022-0096). Two sets of public comments were received, one from Engineering Planning and Management, Inc. (EPM), and one from the Nuclear Energy Institute (NEI). Their original submissions can be reviewed in the NRCs Agencywide Documents Access and Management System (ADAMS) under the following accession numbers:

Comments from EPM: ML22165A134 Comments from NEI: ML22165A208 Their respective comment have been reproduced in the table below, along with their resolution.

Line #, Page No. Reviewer number or Reviewer Comment Suggested Change Resolution Section number The WG reviewed available test results and operating experience with regard to HEAF and arc flash pressure wave effects. The WG concluded the tests provide limited evidence of overpressure effects and no evidence of overpressure creating conditions (projectiles) that could damage external PRA targets during a HEAF.

In general, the WG did not identify HEAF overpressure as a concern.

Additionally, the lack of evidence of ensuing fires from arc blast events and the evaluation of the multi-room hazard via the fire PRA While the assumption of low speed flows makes sense multi-compartment analysis, provides the working group with for thermal impacts, has consideration been given to the confidence that any potential hazard of HEAF pressure effects is 2.2.1 See comment and

1. EPM impact that the a pressure wave would have, including adequately covered by the thermal zones of influence.

Page 41 resolution.

the force of potential metal shrapnel from the cabinet Note that the effects of the pressure wave on the HEAF enclosure enclosure. are addressed by assumption. For LVSWGR, the door to the breaker cubicle with the arc is opened at the start of the event; for MVSWGR, the front door is opened.

To improve clarity in the FDS report, an appendix has been created that documents the WG analysis of the pressure wave effects.

Reference to this appendix has been added to sections 2.1 and 2.3.1.

1 of 7

Determining the Zone of Influence for High Energy Arcing Faults using Fire Dynamics Simulator - Comment Resolution Line #, Page No. Reviewer number or Reviewer Comment Suggested Change Resolution Section number The effects of the magnetic field are not directly modeled as described in Section 2.3.3. However, these effects are considered when developing the HEAF scenarios, in particular where the HEAF is located (see sections 5.1.1.1 and 5.1.2.1 for basis of HEAF Voltage field/magnetic field impacts can have a selected locations). In addition, several sensitivity scenarios are significant affect on plasma shape/direction and particle included in the LV SWGR modeling in which the arc is pushed out of speeds. This can have various impacts on the potential 2.2.3 See comment and the initial compartment into a second compartment (see section

2. EPM ZOIs. A peer review of the approach by others who Page 43 resolution. 5.1.2.1 and 6.2.2.3). The arc migration is in part a reflection of the typically model plasmas should be conducted and magnetic forces present during the arc event. To clarify that the documented. There has been research and modeling of magnetic effects are accounted for in the analysis approach, a this type for plasma thrusters in the aerospace industry.

sentence will be added in Section 2.3.3 that notes that although magnetic forces are not modeled, they are accounted for through the selection of the arc location as described in Sections 5.1.1.3, 5.1.2.3, and 5.1.3.3.

Similar to the treatment of magnetic forces, the effects of 3-phase arcs are not modeled directly, but the overall effect is accounted for in the selection of the arc location and volume. The FDS analysis involved the determination of the exposure conditions at relative far-field locations (enclosure boundary and outside the enclosure Discussion is provided regarding the lack of FDS 2.2.3 See comment and containing the arc) over a time scale that represents 60 or more

3. EPM capability for dynamic 3-phase arcs, but no discussion is Page 43 resolution. phase cycles given the voltage is 60 Hz. The 3 phase effects may provided on the potential impact to the model results.

produce significant near field exposure variations over a few cycles, but these effects would be averaged over the distances and timescales of interest. To improve clarity, a sentence will be added to Section 2.3.3 that notes the effects of 3-phase arcs are bounded by the selection of the arc volume location.

2 of 7

Determining the Zone of Influence for High Energy Arcing Faults using Fire Dynamics Simulator - Comment Resolution Line #, Page No. Reviewer number or Reviewer Comment Suggested Change Resolution Section number This is an assumed value selected that is typical for metals and non-metallic oxides given a lack of available data on metal oxides.

However, as described in Section 3.7.2.3, there is no heat exchange between the melted metal particles and the surrounding vapors, which would result in an overestimate of the gas temperature in the regions of interest. The vapors that combust are conservatively The basis for the single point specific heat for Copper (I) injected from the drop at the drop melting temperature which 3.2 See comment and

4. EPM oxide gas is not provided. If it is an assumed value this minimizes the temperature differential between the gas Page 47 resolution.

should be noted directly. temperature and the injection vapor temperature. The uncertainty introduced with an assumed copper oxide heat capacity is expected to be secondary and bound by these conservative treatments. The description of the copper oxide heat capacity in Section 3.2 is updated to show it is an assumed value and that given the small mass fraction of oxide in the gas phase, errors associated with the specific heat should be small.

3 of 7

Determining the Zone of Influence for High Energy Arcing Faults using Fire Dynamics Simulator - Comment Resolution Line #, Page No. Reviewer number or Reviewer Comment Suggested Change Resolution Section number The WG identified the two potential copper oxidation states during the feasibility studies. There was research data that supported CuO as a dominant reaction and data that supported Cu2O as a dominant form, though at high temperatures Cu2O appeared to be predominant. Given the differences in the reaction rates were small as compared to the reaction rates of aluminum, which was a focus of this analysis, it was determined to use Cu2O as the dominant Copper oxide is naturally found in 2 different forms, oxide form. This selection maximized the difference between Copper (II) Oxide: CuO and Copper (I) Oxide: Cu2O, copper and aluminum and thus was expected to maximize the 3.2 depending upon the oxidation state of the copper cation. See comment and

5. EPM differences in aluminum and copper electrodes. Since the overall Page 47 Only Cu2O is discussed by this report. The relative resolution.

result of the analysis concluded that the ZOIs for aluminum and contribution (or exclusion) of CuO is not copper are similar, the impact of the oxide reaction is secondary defined/demonstrated.

and would not affect the overall results. A clarification is added to Section 3.2 that indicates the oxide with a lower reaction energy is selected to maximize the differences between aluminum and copper. However, the reaction energy of both copper reactions is small compared to aluminum and given the small concentration of metal oxide in the gas phase, the difference in energy between CuO and Cu2O is small compared to the total arc energy.

See response to comment 5. Note that the energy evolved during the combustion of the metal vapors was a small fraction of the The heat of reaction for Cu2O as noted is 1340 kJ/kg .

overall energy budget. As such, the results were not expected to be However for CuO it would be approximately 2460 kJ/kg.

3.5 See comment and sensitive to the copper oxide reaction energy for the assumed

6. EPM If Cu2O is expected to be the dominant product, this Page 48 resolution. copper oxide. This may be seen by comparing similar configurations should be noted. Currently the relative contribution (or in which an aluminum electrode is used, which has a higher exclusion) of CuO is not defined/demonstrated.

combustion fraction (75% vs. 25%) and a significantly higher heat of reaction (31 MJ/kg vs, 1.34 MJ/kg).

4 of 7

Determining the Zone of Influence for High Energy Arcing Faults using Fire Dynamics Simulator - Comment Resolution Line #, Page No. Reviewer number or Reviewer Comment Suggested Change Resolution Section number The validation results focuses on a few HEAF experiments in controlled environments and a couple industry events. Has consideration been given to any potential additional variables in live Nuclear Power The event at Turkey Point (FEDB #51634) is described and assessed Plants that may increase severity of the HEAF seen in in the HEAF Frequency and Consequence Modeling Report (i.e., the 4 other events. Back in 2017 there was a HEAF event at See comment and

7. EPM PRA report). Additional discussion is provided in Appendix E of this Page 63 Turkey Point that was powerful enough to blow open a resolution.

report in the context of pressure wave effects. This appendix is fire door and is what sparked the potential aluminum noted in Sections 2.1 and 2.3.1.

increasing the HEAF severity discussion. Some of the most severe events should be discussed somewhere in the report. Perhaps some form of severity factor is needed to capture these anomalies.

A single bias factor and standard deviation is used in the determination of the ZOIs. This is discussed in new Section 4.1.4. It Consider adding a summary table of the bias factor and is not recommended at this time that a user select different 4.5 See comment and

8. EPM standard deviation for each phenomena to the end of uncertainty parameters and adjust the results separately from what Page 79 resolution.

this section as a quick reference for the end user. is done in the report. However, a table is provided that lists the bias and standard deviation for each test duration and rack grouping (Table 4-3).

5 of 7

Determining the Zone of Influence for High Energy Arcing Faults using Fire Dynamics Simulator - Comment Resolution Line #, Page No. Reviewer number or Reviewer Comment Suggested Change Resolution Section number The analysis approach incorporates a larger number of assumptions with respect to the arcing phenomena and the response of the enclosure containing the arc than the types of applications covered in NUREG-1824 Supplement 1. These assumptions tend to result in greater uncertainty in the results that is reflected in the small bias factor. In addition, the timescales over which the analysis is A bias factor of only 0.57 for the predicted exposure concerned are short and comparable to the breach times for the suggests gaps in the FDS capabilities may be significant. metal enclosures. As noted in Section 4.1.4 of the report, small Other FDS-based validation for NPPs in NUREG-1824 are differences in predicted breach time, which may be due to 4.5 See comment and

9. EPM much closer to 1.0 for most phenomena (except where assumptions associated with the arc location, the response of the Page 79 resolution.

overprediction is conservative such as smoke). Additional metal enclosure, and the assumed arc power, result in large discussion may be warranted regarding the acceptability differences in the predicted target exposure. When these effects of the model results. are incorporated into the model results with the model bias, the overall predictions are reasonable and useful for developing insights for different enclosure configurations and arc power.

An updated description is provided in Section 4.5 that summarizes the use of the bias factor and notes the reasons that it is low relative to NUREG-1824 S1 data.

The summary mentions the future PRA guidance but it should be noted here, like it is in the scope, that this At this time, the PRA report is being prepared for public comment 7 guidance will be in a separate report. If at all possible See comment and and does not have a number. The latest information on the PRA

10. EPM Page 203 before this report is finalized it would be helpful to resolution. report will be incorporated into the reference details when the FDS reference the report name/number for those looking to report is finalized for publication.

use the guidance.

6 of 7

Determining the Zone of Influence for High Energy Arcing Faults using Fire Dynamics Simulator - Comment Resolution Line #, Page No. Reviewer number or Reviewer Comment Suggested Change Resolution Section number Executive This section includes a statement that for vertical-lift Clarify whether or not Summary breaker style switchgear in the supply configuration, this is applicable to

11. NEI Intent is medium-voltage SWGR. Added clarification.

(page xxix, there is no vertical (top) ZOI component. It is unclear if medium voltage 2nd bullet) this is true for medium voltage switchgear. switchgear.

The basis for excluding the pressure wave effects from the ZOI The assumption that the pressure wave does not have an Provide a technical basis analysis is developed and documented in a new appendix

12. NEI Page 2-1 impact on PRA targets is not clearly justified. for the assumption. (Appendix E). Reference to this appendix has been added to Section 2.1.

Section 5

13. NEI Development is misspelled Correct spelling Corrected spelling.

Heading This section includes a statement that for vertical-lift breaker style switchgear in the supply configuration, Clarify whether or not Section there is no vertical (top) ZOI component. It is unclear if this is applicable to

14. NEI 6.1.3.3 (Page this is true for medium voltage switchgear. Table 6-1 Applies to MV SWGR. Clarified (see comment 11).

medium voltage 6-34) shows non-zero ZOIs for TOP of PCCBB Supply. Table 6-switchgear.

1 also shows zero front ZOI for the vertical-lift, load configuration.

Include statement The descending ZOI from bus ducts is not re-evaluated and remains specifying findings generally the same (i.e., the waterfall component). The PRA report It is not clear if this report included re-evaluation of the related to this re- discusses the application of this ZOI component to bus ducts. The

15. NEI Section 6-3 ZOI descending from Non-Segregated Bus Ducts as evaluation, or explicitly primary difference involves the locations where this is postulated.

suggested by Supplement 1 to NUREG/CR-6850.

state that it was not re- A new section 2.2 is added that describes the ZOI components, and evaluated. which are covered in this report.

7 of 7